JIS Symbol Auto feed lube Piping example Filter Regulator Auto feed lube Air Oil Auto feed tank PT ALF400 ALT-9 Oil distributor Auto feed tank 14-13-6
2 Auto Feed Lube, Auto Feed Tank Series ALF400 to 900, ALT-5, -9 How to Order
Body Size: 30, Backflow: without Backflow Function, Thread: N (NPT), IN Port Size: 02 (1/4), OUT Port Size: 02 (1/4), Options: J (Right Angle Square Type Pressure Gauge w/Limit Indicator), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Body Size: 20, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 02 (1/4), OUT Port Size: 02 (1/4), Options: J (Right Angle Square Type Pressure Gauge w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Y (Upward), Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Body Size: 20, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 02 (1/4), OUT Port Size: 02 (1/4), Options: J (Right Angle Square Type Pressure Gauge w/Limit Indicator), Set Pressure: 1 (0.02 to 0.2 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)
Through-hole/Both ends tapped common (Basic) S T R Q H (Rod size) AE (Rc, NPT, G) (2 locations) (Port size) E effective thread depth F Yh9 Z X 5.5 (The dimension on the opposite side is the same.) I (4 locations) 0.1 0.2 D G W AC (4 locations) (The dimension on the opposite side is the same.) A AA C J L L J K (4 locations) Flat washer With 4 pcs.
With auto switch CRQ2B S 20 90 CDRQ2B S 20 90 A90 S Shaft type Built-in magnet Single shaft Double shaft S W Rotation 90 80 to 100 170 to 190 180 Size Shaft type 10 15 20 30 40 Air cushion Single shaft Double shaft S W Rotation Air cushion Without Without With Sizes 10, 15 Nil Nil C 90 80 to 100 170 to 190 180 Size 20, 30, 40 10 15 20 30 40 Air cushion Auto switch model Air cushion Without
Power is supplied S S S SET (S) button Press this button to change the mode and to set a value. L Press the S button for 2 seconds or longer. DOWN () button Selects the mode and decreases the ON/OFF set value. M Setting F0 Setting F1 Setting F99 N Indicates the unit currently selected. Unit display The output will not operate for 3 seconds after supplying power.
MOperation sequence diagram M Operation sequence diagram 4 output points Two-time hitting only for CH2 ON for 1 s OFF for 2 s Stop signal ONt For CH1 OFFt CH2 OFFt CH3 Power supply ON time CH4 2 s 1 s tA tA 1 s CH1 2 s 2 s 2 s 2 s OFFt 1 s 1 s 1 s 1 s CH2 2 s Two-time hitting 1 s CH3 2 s 1 s CH4 Power switch ON (Output start) Power switch OFF (Output stop) Cascade Connection (Multiple-board
Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89
CRBU Basic (Side port) CRB1FW Basic (Axial direction port) CRB1FW W/ angle adjuster CRB1FWU W/ auto switch CDRB1FW W/ angle adjuster and auto switch CDRB1FWU Size Size Size Size Size Angle , #11 (#1+#11) , #12 (#3+#12) , #13 (#5+#13) , #14 (#7+#14) , #15 (#9+#15) S SCRB SE SCRB S SCRB S SCRB S SCRB Size Size Size Size Size Angle Angle CRA1 Angle Angle CRQ Ass'y Part Number: P211070
B C D E F G H J K L M N P Q R 31.5 34.2 IDFB55E 2 1.4 [800] [868] 18.5 33.7 5.0 17.9 4.3 9.8 2 0.5 19.70.1 3.0 27.60.04 20.7 20.40.2 [470] [855] [128] [455] [110] [250] [50] [13] [5002] [75] [7001] [526] [5195] [36] 35.4 38.1 IDFB75E 2 [900] [968] IDFB Series 6-3 6-2 IDX-OM-W035 6 6-4 IDFB22E-11 IDFB22E/37E-23 R GFCI GFCI R GFCI R GFCI L N PE R TB1 PE N L 1 2 TB1 1 2 1 2 S MC S C1 IDFB22E
1090 2 -67No.PF-OMM0004-D (PVC ) PF3W711 PF3W721 (3 mPas(3 cP)) 1 10100 L/min 30250 L/min 7140 L/min(7 L/min 0) 20350 L/min(20 L/min 0) 7140 L/min 20350 L/min 1 L/min 2 L/min (50 ms) 1 L/pulse 070 () L/minL 3F.S. 3F.S. 2F.S. 2 5%F.S.(25 ) 3 3 9 L 4 1L NPN PNP 80 mA DC28 V NPN1 V (80 mA ) PNP1.5 V (80 mA ) 25 0.5 s/1 s/2 s 6 0.5 s/1 s/2 s 15 V 1 k 420 mA DC12 V 300
0 100 200 300 400 500 280 560 Data 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load weight W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average speed Va mm/s 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Note) Use the average speed when calculating static moment.
CC Graph 2 Note) Be sure to use a flat washer to mount cylinders via through holes. 3 MK2l50/63 2 MK2l32/40 102 When arm's moment of inertia is 5 X 103kg/m2, cylinder speed should be less than MK2l32/40: 66mm/s MK2l50/63: 120mm/s Refer to p.4.1-21 for calculating moment of inertia.
Fittings & Tubing Air Cylinders Rotary Actuators Basic (Without switch rail) 11-MXJ6-N Operating port 2 x M3 x 0.5 J 12 I (Plugged when the product is a symmetric type.)
Features 1 Compact Cylinder Double Acting, Single Rod Bore size: 056 (9/16), 075 (3/4), 106 (1-1/16), 150 (1-1/2), 200 (2), 250 (2-1/2) Series NCQ8 How to Order Without auto switch B 056 025 NCQ8 B 056 025 Z M9B S NCDQ8 With auto switch X-Option Built-in magnet Nil XB6 XC4 Standard High temp.
CXT 12 16 CXT20 CXT25 CXT 32 40 Model Symbol Specifications -XB13 Shock absorber model Low speed cylinder (5 to 50 mm/s) RB2015 RB1411 RB1007 RB0806 Max. energy absorption (J) 58.8 14.7 5.88 2.94 Stroke absorption (mm) 15 11 7 6 Collision speed 0.05 to 5 m/s Max. operating frequency (cycle/min) 25 45 70 80 10 to 80C Ambient temperature Extended 8.34 6.86 4.22 1.96 Spring force (N) Retracted
MXU MXS CXTl 12 16 CXTl20 CXTl25 CXTl 32 40 Model MXQ Shock absorber RB2015 RB1411 RB1007 RB0806 Max. absorbed energy (J) 58.8 14.7 5.88 2.94 MXF Absorbed stroke (mm) 15 11 7 6 Collision speed 0.05 to 5m/s MXW Max. operating frequency * (cyc/min) 25 45 70 80 Ambient temperature 10 to 80C MXP Expanded 8.34 6.86 4.22 1.96 Spring force (N) MG Compressed 20.50 15.30 6.86 4.22 Weight (g) 150 65
The range in the chart below that is delineated by bold solid lines indicates the relation between load weights and maximum driving speeds. 6 8 10 Bore size (mm) 0.05 to 0.4 Piston speed (m/s) 6.25 x 10-3 9.35 x 10-3 12.5 x 10-3 Allowable kinetic energy (J) 10 6 8 10 Load weight (kg) 1 0.1 0.01 0.1 0.4 1.0 0.01 Maximum speed V (m/s) 52 Actuator / Common Precautions 1 Be sure to read before
How to Order Port Number q w e r KT10 L S 4PW 0 0 FV4 FV4 1 Delivery Pressure Delivery pressure Code 5 to 500 psig (0.034 to 3.4 MPa) 5 to 800 psig (0.034 to 5.5 MPa) 10 to 1500 psig (0.07 to 10.3 MPa) 15 to 2500 psig (0.1 to 17.2 MPa) 25 to 4000 psig (0.17 to 27.6 MPa) Installation option Code Installation Bottom mount (Standard) Panel Installation F No code P H J Option Code Specification