Bore Size: 10mm, Action: D (Double Acting), Body Option: Basic Style, Dust Cover: Chloroprene Rubber (CR), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X5 (Fluororubber Seal)
MY-S25 MY-S32 MY-S40 Applicable cylinder A 105 130 145 B 119 148 167 C 35 45 55 D 50 64 80 E 8 11.7 14.8 F 5 6 8.5 G 9.5 11 14 H 5.5 6.6 9 J M6 x 1 M8 x 1.25 M10 x 1.5 A B A B A B MY1H25 MY1H32 MY1H40 MY1 HT Side supports consist of a set of right and left supports.
Side support B MY-SB 2 x J MY1B MY1B MY1H E A B MY1B C D MY1M (mm) MY1C A 61 70 87 B C D E F G H J Part no.
Fittings & Tubing Air Cylinders Rotary Actuators How to Order 10 R E C L 25 150 M9BW C Number of auto switches Mounting Nil S n B L F G 2 pcs. 1 pc. n pcs.
W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable bore size 12 16 20 25 D-M9m(V)/
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
C D Side support B MY-SB 2 x J 2 x H C D A B A B C D E F G H J Applicable cylinder MY1W16 MY1W20 MY1W25 MY1W32 MY1W40 MY1W50 MY1W63 Model MY-S16A 61 71.6 15 26 4.9 3 6.5 3.4 M4 x 0.7 B MY-S20A 67 79.6 25 38 6.4 4 8 4.5 M5 x 0.8 B MY-S25A 81 95 35 50 8 5 9.5 5.5 M6 x 1 B MY-S32A 100 118 45 64 11.7 6 11 6.6 M8 x 1.25 B 120 142 MY-S40A M10 x 1.5 55 80 14.8 8.5 14 9 B 142 164 MY-S63A 172 202
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height Auto Switch Proper Mounting Position (mm) D-A3 D-A44 D-G39 D-K39 D-G5NBL D-H7 D-H7C D-H7W D-H7NF D-H7BAL Auto Switch model D-C7 D-C80 D-C73C D-C80C D-M9 D-M9W D-B5 D-B64 D-B59W D-A9 D-G5NTL Bore size (mm) A B A B A B A B A B A B A B A B 20 55.5 30.5 59.5 34 56 31 50 25 53 28 49.5 24.5 55 30 51.5 26.5 25 55.5
Fig. (4) Fig. (5) 388 Rotary Clamp Cylinder: Standard 12, 16, 20, 25, 32, 40, 50, 63 MK Series How to Order MK 10 R 20 B N Z M9BW Rotary clamp cylinder Made to Order (Refer to page 390 for details.) Mounting bracket Auto switch type Mounting Symbol Nil S Through-hole/Both ends tapped common (Basic) 2 pcs. B 1 pc.
B Counter bore depth C T T Y HT HP P (Piping port) (Operating direction: A) L 0 -0.1 22 8 Note 1) TC X F 14 WP 19.5 12.5 D 30 13 WS GP GW 4 x LD PW QW Plug 12.5 P (Piping port) (Operating direction: B) 2 x 4 x MM Thread depth M Switch rail HR HS CR W K Plug G G Z + Stroke Q + Stroke CY3RG15 P (Piping port) (Operating direction: B) CY3RG25, 32, 40, 50, 63 Note 1) 50, 63: L 0 0.2 CY3RG10 B
BS Bumper bolt (resin tipped): Plate B side or C side Shock absorber Applicable Auto Switches/Refer to pages 1575 to 1701 for further information on auto switches.
8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433: *2) 1. 2. 3. 1. 2. 3. 4.
+ Stroke K A + Stroke M G J W 16 Minimum lead wire bending radius 10 Auto switch Q F 4 x N through H thread effective depth C 2 x M3 x 0.5 (Port size) I D M E Z L B + Stroke K A + Stroke M G J W Standard [mm] Bore size Stroke range Without magnet for auto switch With magnet for auto switch C D E F G H I J K L M N Q W Z A B A B 12 5 to 30 19.5 16 23 19.5 6 6 23 4 21.5 M3 x 0.5 26 1.5 5 3.5
B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.
A Hs 32 to 63 D-P3DWA B A Hs Auto Switch Proper Mounting Position Auto Switch Mounting Height (mm) (mm) D-M9 D-M9V D-M9W D-M9WV D-M9A D-M9AV Auto switch model Auto switch model D-A9V D-P3DWA D-M9V D-M9WV D-M9AV D-A9 D-A9V D-P3DWA Bore size (mm) Bore size (mm) B 11 12.5 13 15 16 20 A 11 10.5 12 14 13.5 16.5 B 7 8.5 9 11 12 16 A 6 7.5 9.5 9 12 B 8 8.5 10.5 11.5 15.5 Hs 24.5 26 29 33 38.5
a PA + Stroke E FB FA e c d A + Stroke B + Stroke C + Stroke T-slot dimensions [mm] [mm] Bore size [mm] a b c d e Bore size [mm] f f 12 3.3 5.8 2.6 1.6 4.8 16 3.7 6.2 3 2.5 6.5 20 5.4 8.4 4.5 2.8 7.8 25 5.4 8.4 4.5 3 8.2 12 7 16 2.5 20 8.5 25 6 50 mm stroke or less Top-ported type The use of a slot (width XA, length XB, depth 3) allows for a relaxed pin pitch tolerance, with the pin hole
[ ]: Value of the D-M9A ( ): Value of the D-A90/A93 D-M9V D-M9WV D-M9AV D-A9V A 20 (22) W B ( ): Value of the D-M9AV/A9V (mm) D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V A 16.5 15.0 22.0 30.0 D-M9A A 16.5 15.0 22.0 30.0 D-M9AV A 16.5 15.0 22.0 30.0 Bore size (mm) 6 10 16 20 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 W 5.5 0 0 2.5 W 7.5 2.0 2.0 0.5 B 2.5 7.5 8.0 10.5 B 2.5 7.5 8.0 10.5 A 16.5 15.0 22.0