SMC Corporation of America
Elite Part Number Search
Search Results "HRS018-AN-10-B"

Double acting 10 Single acting, Spring return 7-2-2 7-2-3 3 Mini-free Mount Cylinder Series CUJ 4, 6, 8, 10 How to Order Bore size 4 6 8 10 4 mm 6 mm 8 mm 10 mm 10 6 D CUJ B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Without auto switch D 10 CDUJ B 6 F8N S With

Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker

Type: Thermo-Chiller, Cooling Method: Water Cooling, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: Rc, Optional specifications: With earth leakage circuit breaker

Type: -, Cooling Method: -, Cooling Capacity: 1,700/1,900 W (50/60 Hz), Piping thread type: NPT (PT-NPT conversion fitting set included), Optional specifications: With earth leakage circuit breaker

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: N (NPT w/PT-NPT Conversion Fitting Set), Option: B (Earth Leakage Breaker)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: A (Air-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Cooling Capacity: 018 (Cooling Capacity: 1700/1900W, 50/60 Hz), Cooling Method: W (Water-cooled Refrigeration), Thread: Rc, Option: B (Earth Leakage Breaker)

Note 2) Vibration resistance: No malfunction resulted in a one-sweep test in a 10 to 300 Hz range in the axial and right angle directions of the main valve and armature, for both energized and de-energized states. Shock resistance: No malfunction resulted in an impact test using a drop impact tester.

(made by SMC) Operating ambient temp: -10 to +50 oC Storage ambient temp: -20 to +60 oC 1: Input terminal are not isolated from Power source. 2: Do not connect outside Power source to Input and Output terminals. 62 63 0 1 1 1 1 1 1 1 1 1 1 1 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

7 19 14 M22 x 1.5 26 1/4 83 159 100 Up to 500 40 37 110 41 87 26 50 10 14 66 16 M10 x 1.25 12 23 14 M26 x 1.5 28 3/8 88 168 Rod end nut (Standard) 30 d D C H B [mm] Part no.

A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)

A part z1 m1 = 20 x 3 x 4 x 2.7 x 10-6 = 6.48 x 10-4 (kg) Weight calculation m1 = a x b x c x Relative density IZ1 Inertial moment around Z1 axis IZ1 = {m1 (a2 + b2) / 12} x 10-6 = {6.48 x 10-4 x (202 + 32)/12} x 10-6 = 2.21 x 10-8 (kg.m2) = 2.21 x 10-8 + 6.48 x 10-4 x 16.42 x 10-6 = 0.20 x 10-6 (kg.m2) IA Inertial moment around Z axis IA =IZ1 + m1r12 x 10-6 z f2 z2 B part r2 = 23.5(mm)

hole) I J K L M N O P Model ZM ZH05DS-06-06-06 ZH05DL-06-06-06 ZH07DS-06-06-06 ZH07DL-06-06-06 ZH10DS-06-06-08 ZH10DL-06-06-08 ZH13DS-08-10-10 ZH13DL-08-10-10 ZH15DS-10-12-12 ZH15DL-10-12-12 12.8 6 24 21 7.8 6 17 24 12.8 6 24 21 6 17 24 12.8 6 24 22 6 17 24 12.8 6 24 22 6 17 24 13.7 6 26 24.5 8 20 28 13.7 6 26 24.5 8 20 28 15.3 10 28 27 10 22 30 15.3 10 28 27 10 22 30 Applicable tubing diameter

Auto switch Finger position Model D-M9 Open Closed Open Closed Open Closed Open Closed 8 10 4 7 5 2 MHZ2-10 1122MHZ2-16 1122MHZ2-20 1122MHZ2-25 1122[Mounting of Auto Switch: Precautions] When mounting an auto switch on the piping port surface of the 11-MHZ2-10, the auto switch may not be mountable due to interference with the fitting.

AS42l1FE AS43l1FE Model 8 10 6 8 10 12 12 10 6 8 10 Tube O.D.

B(9.5) B(12.7) B(19.1) 1B(25.4) 1 B(31.8) 1 B(38.1) 2B(50.8) VNA 111 211 311 411 511 611 711 AS 420-03 420-04 500-06 600-10 800-12 900-14 900-20 Caution Warning 1Piping When operation is suspended, surge pressure will be generated between the cylinder and VNA11A.

The product does not have an explosion proof construction. Be sure to take measures to prevent the area around the product from becoming filled with an explosive gas, when using an explosive fluid. 56

F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.

(Use a hexagon wrench.) (3) Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. (4) After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. (5) When changing the detecting position, carry out in the state of 3.