**Valve opens when solenoid valve stops conducting electricity. voltage 110V, 220V AC/6, 12, 48, 100V DC 50Hz: 14VA 60Hz: 13VA Inrush AC Apparent power 50Hz: 9VA 60Hz: 8VA Holding DC 6.5W MK/MK2 Electrical entry Grommet (Standard), Conduit, DIN terminal RSQ/RSG RSH CE1 CE2 ML2B ML1C REA REC RHC MTS CC (mm) Model Oil port size (Rc(PT)) A B CA* CL* GB GL KA KB KL L QA M NB NL QB QL R T GA F
AFJ AFJ r t y u w AMV q Body size 20 30 40 ZH -X185 Symbol Description Related Products w Pipe thread type Nil Rc N NPT F G + 01 1/8 02 1/4 03 3/8 04 1/2 + e Port size Option a Mounting Nil Without mounting option r B Note 1) With bracket + b Element 5 5 m 40 40 m 80 80 m + Nominal filtration rating t c Water drop removal type/ Large flow type S Water drop removal type Type y T Large
C E1 R U E1 U1 U1 A1 NX 8.6 A1 H L1 L1 NX Part no.
1 8 29.0 32.0 27.5 35.5 17 17.6 R 1 4 R 3 8 R 1 4 R 3 8 R 1 2 R 3 8 R 1 2 19 25.2 31.0 22 35.5 31.5 24 27.0 Reference dimensions after R thread installation.
(mm) 8 6 4 Model 10 12 Connection thread Male connector KSH KXH M5 x 0.8 M6 x 1 1 8 R K R 1 4 M R 3 8 H R 1 2 Male elbow KSL KXL D M5 x 0.8 M6 x 1 MS R 1 8 T R 1 4 VMG R 3 8 R 1 2 Precautions Be sure to read before handling.
) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Bracket 2-port size (Option) Maintenance space M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 146 167 167 198 198 I 56 66 66 80 80 J 15 20 17 22 19 K 5 8 8 8 8 L 9 12 12 14 14 N 35 40 40 50 50 O 54 66 66 80 80 P 70 84 84 100 100 Q 26 28 28 34 34 R 4.5 5 5 5 5 S 1.6 2.0 2.0 2.3 2.3
Remarks Power supply/output cable ZS-26-L Length 2 m Connector for sensor lead wire ZS-28-C 1 pc.
(Refer to page 226.) 2 position single 2 position double 4(A) (B)2 (B)2 4(A) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no. 1 (P) (R)3 5(R) 5(R) 1 (P) (R)3 3 position exhaust center 3 position closed center 4(A) (B)2 4(A) (B)2 (Ex.) SS5YJA7-41-03-01 1 pc. SYJA7140 1 pc. SYJA7240 1 pc.
) 3 (R) 5 (R) 1 (P) 3 (R) Note 1) Impact resistance: No malfunction resulted from the impact test using a drop impact tester.
M Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G S 6.0 , 2 H 463.5 I 180 J 30 K 15 L 24 N 120 O 184 P 220 Q 110 R 18 460.5 AMG850 1 2 13 42 348 220 57.5 220 10 14-20-7
1 (P) 3 (R) (Example) SS5YJA5-42-03-01 1 set SYJA5140 1 set SYJA5240 1 set SYJ5000-21-1A 1 set 3 position closed center 3 position exhaust center (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 3 (R) 1 (P) 3 (R) The asterisk denotes the symbol for assembly.
Compact Direct Operated 2 Port Solenoid Valve for Water and Air SeriesVDW10/20/30 VX2 How to Order Valves (Single Unit) VXD For Water, Air, Vacuum VD W 2 1 1 G 2 01 VXZ VXE Made to Order (Refer to page 244.) Series VXP 1 2 3 10 N.C.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance P Peak hold mode Shows the maximum pressure reached at that moment.
r r r q w e OUT side passage IN side passage y u t OUT IN i o Basic type (Knob): IR30l0-A e e r q r w e OUT side passage IN side passage t u OUT IN o i Basic type (Knob): IR30l1 2-A e e r q r w e OUT side passage IN side passage t u OUT IN o i 800 Precision Regulator IR1000-A/2000-A/3000-A Series Dimensions Basic type (Knob): IR10l0-01l-A 10.5 42 ARJ 1.6 Bracket AR425 to 935 Mounting hole
Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: M (SI Unit Only, Fixed Unit: kPa, MPa), Piping Specification: 01 (R1/8)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8)
Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: -, Bracket: -, Operation Manual: -