Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: NPT1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A1 [Bracket A (ZS-46-A1)], Operation
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6
The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., DIGITAL PRESSURE SWITCH, PRESSURE SWITCH, ISE1-6, 76 lb
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
This is a legacy product, and replaced byVM131-N01-01SA, MECH VALVE NON-EXCH.
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
3.5, 2 m Conductor area: 0.15 mm2 (AWG26) Insulator O.D.: 0.95 mmCE marking, UL (CSA), RoHS compliance
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g
5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm PSE56 - -28: Oil proof heavy-duty vinyl cable with air tube, 2 cores, ?5.1, 3 m, Conductor area: 0.2 mm2, Insulator O.D.: 1.12 mm194 g102 g