Upward) 2B 33 49 (56.5) 40.5 97 1/8 [Pilot port: Lateral (-P)] 31.5 36 17.5 7 20.5 2 x 4.2 (For mounting) 1/8, 1/4 [1(P)port] (18.4) (18.4) (Distance between ports) 1/8 [5(EA), 3(EB)port] 7.5 1P 3EB 8 7.5 5EA 2 x 2 (Breathing hole) 36 51.5 35.5 1503 VFA1000/3000/5000 Series Dimensions: VFA5000 Series/Body Ported 2 position single VFA5120(-P) 02 03 2 position double VFA5220(-P) 02 03 119 110
system Protocol Communication specification Output specification Environmental resistance Release 2.0 Ver. 1.10 Version Note 1) 156 k/625 kbps 2.5 M/5 M/10 Mbps Communication speed 125 k/250 k/500 kbps Specified file Note 2) EDS file Occupied area (Number of inputs/outputs) SDN1: 0/32 SDN2: 0/16 32/32 (1 station, remote I/O stations) Terminal resistor Built in the unit (Switch setting, 110
Pulling Strength Model Without inner sleeve With inner sleeve TU1208 140 N 500 N TU1065 140 N 450 N TU0805 110 N 250 N TU0604 80 N 180 N TU0425 50 N 160 N Reference: Thrust Force Occurring at 0.8 MPa Model Load TU0425 10 N TU0604 25 N TU0805 40 N TU1065 65 N TU1208 90 N Note 3) Please consult with SMC regarding applicable tube separately.
Level (Initial conditions) End plate End plate AN200 to 900 Condition: 0.5 MPa at inlet pressure of solenoid valve Measurement distance: AN200 to 500 1 m, AN600 to 700 2 m, AN800 to 900 3 m Tension bolt Sound absorbing material (PE sintered body) Sound absorbing material (PE sintered body) Cover Case Without silencer With silencer Body 130 Hexagonal flats 120 Port size Hexagonal flats 110
R 3 VDC 8 One-touch fitting C8 10 One-touch fitting 8 One-touch fitting 10 One-touch fitting 12 One-touch fitting 2(B) (A)4 Rated voltage 10-SY7000 C10 C8 C10 C12 3 For AC ( Hz) 50 60 Thread type (EA)5 1 (P) 3(EB) 1 100 VAC 2 200 VAC 10-SY9000 Rc Nil 3 position exhaust center F G 2(B) (A)4 3 110 VAC [115 VAC] N NPT One-touch fitting (Inch size) 4 4 220 VAC [230 VAC] NPTF T Symbol Port size
In the case of 110/220 VAC, the VDW10 is 3 W and the VDW20/30 is 3.5 W. Note 4) Vibration resistance No malfunction when tested with one sweep of 5 to 200 Hz in the axial direction and at a right angle to the armature, in both energized and deenergized states.
Where the load voltage is 110 VAC When the load voltage is increased by more than 10% to the rating of applicable auto switches above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the range of the load current range, 110 VAC.
(mm) Port size Av x 10-6m2 Cv converted 10 10 15 10 15 20 25 35 40 50 1/4 (8A) 1.9 2.4 4.5 2.4 5.5 9.5 13 23 31 49 46 58 110 58 130 230 310 550 740 1200 VXED2130-02 VXED2130-03 VXED2140-03 VXED2130-04 VXED2140-04 VXED2150-06 VXED2260-10 VXED2270-32 VXED2380-40 VXED2390-50 420 0.5 3/8 (10A) 670 500 670 1150 1650 5400 6800 8400 1.0 0.5 Thread (Nominal size) 0.02 1/2 (15A) 1.5 3/4 (20A) 1 (25A
OPTIONS AND AUXILIARY EQUIPMENT (3) Outline drawing (a) EMC filter HF3010A-UN [Unit: mm] 3-M4 4-5.5 7 3-M4 M4 32 2 110 4 85 2 IN Approx.41 258 4 65 4 273 2 288 4 300 5 HF3030A-UN HF-3040A-UN 6-K 3-L 3-L G 1 F 2 E 1 D 2 M J 2 C 1 C 1 H 2 B 2 A 5 Dimensions [mm] Model A B C D E F G H J K L M HF3030A-UN 260 210 85 155 140 125 44 140 70 R3.25, M5 M4 length 8 HF3040A-UN 260 210 85 155 140 125
(3) (a) EMC HF3010A-UN [:mm] 4-5.5 7 3-M4 3-M4 M4 32 2 110 4 85 2 IN (41) 258 4 65 4 273 2 288 4 300 5 HF3030A-UNHF3040A-UN [:mm] 6-K 3-L 3-L G 1 D 2 E 1 F 2 M J 2 C 1 C 1 H 2 B 2 A 5 [mm] A B C D E F G H J K L M HF3030A-UN 260 210 85 155 140 125 44 140 70 R3.25 8 M5 M4 HF3040A-UN 11 30 11.
D7 D6 D5 D4 D3 D2 D1 D0 SEL_MON2 SEL_MON1 D7 D6 D5 D4 D3 D2 D1 D0 SEL_MON4 SEL_MON3 8-110 8 MECHATROLINK-II Commands 8.18.4 Monitor Information Field Specifications: MONITOR 1/2/3/4 The monitor information (MONITOR 1/2/3/4)field is used to monitor information selected by the monitor codes in the monitor selection field.
(1 bit) 145 20 10 85 15 10 Reading of internal parameters (7 words) 270 40 15 150 25 10 Operation mode selection 165 25 10 95 15 10 Commands for virtual I/O operation by serial communication 195 30 15 110 20 10 Reading of alarm history (4 words) 215 30 15 120 20 10 Clearing of alarm history 245 35 15 135 20 10 Confirmation of communication connection 165 25 10 95 15 10 The communication
/ IDFB90 0.77 0.82 0.86 0.90 0.94 1.00 1.07 1.16 1.18 Ambient temperature oF 80 90 100 110 113 oC 27 32 37.8 43 45 IDFB60 / IDFB70 1.16 1.11 1.00 0.78 0.71 IDFB80 / IDFB90 1.40 1.22 1.00 0.88 0.83 Calculation example: The air flow capacity when the dew point of IDFB60 is set to 10 oC under the following conditions < Operating conditions: Inlet air temp: 100oF, Inlet air pressure: 90psi,
2 0.981 1 735.559 14.217 9.80710 4 28.959 1kgf/cm -3 1.35910 -3 1 1.93310 -2 1.33310 2 3.93710 -2 1mmHg 1.33310 3 2.037 1PSI 0.069 0.070 51.715 1 6.89510 -5 1.01910 -5 7.50110 -3 1.4510 -4 1 2.95310 -5 1Pa 110 -2 3.45310 -2 2.54010 1 4.90910 -1 3.38510 3 1 1inHg 3.38810
122 134 146 158 98 110.5 123 135.5 148 160.5 173 185.5 135.5 185.5 L1 L3 (L4) 12.5 13.5 110 158 125 175 DIN Rail (7.5) 5 49 32.2 39.7 1 2 3 L4 [mm] L3 [mm]: Manifold length L2 [mm]: Mounting pitch L1 [mm]: Rail length Installation When only input blocks for M12 connector are connected Tighten the bolts of Input unit and end block to secure the jointed unit and blocks to DIN rail.
Figure 3) L RUN Setting communication speed Type of cable Terminating resistor Communication speed No.8 No.9 No.10 CC-Link-dedicated cable Built-in terminal resistance 110 (DIP SW2-No.2) ON 110 1/2 W CC-Link-dedicated cable 156 kbps 0 0 0 CC-Link-dedicated high-performance cable 130 1/2 W To obtain more detailed information about operating this product, please refer to the SMC website
1/2 W 110 (DIP SW-No.2) ON CC-Link Ver.1.00 130 1/2 W SI CC-Link SI 17 ON CC-Link Ver.1.00 130 -12No.EX-OMP0004CN-I PWR INM12 5 B codeSPEEDCON 1 SV24 V +24V 2 SV0 V 0 V 3 SI24 V +24 V 4 SI0 V 0 V 5 M12 SPEEDCON SPEEDCON SPEEDCON 1/2 SPEEDCON M12 -13No.EX-OMP0004CN-I SV SI DC24 V /28 SV DC24V SI DC24V A.
OFF Disable Communication cable for CC-Link With socket for BUS IN PCA-1567720 With plug for BUS OUT PCA-1567717 Built-in terminating resistor 110 Set the SI unit DIP Switch-No.2 to ON 110 1/2 W Output number assignment Output numbering starts at zero and refers to the solenoid position on the manifold.
Standard Stroke (mm) Manufacturable stroke range Model Standard strokes CXSJ6 CXSJ10 CXSJ15 CXSJ20, 25, 32 60 to 100 10, 20, 30, 40, 50 80 to 150 10, 20, 30, 40, 50, 75 110 to 150 10, 20, 30, 40, 50, 75, 100 110 to 200 Strokes beyond the standard stroke range are available as a special order.
Theoretical Output (N) Operating pressure (MPa) Rod diameter (mm) Piston area (mm) Operating direction Model 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.15 39.2 33.6 28.0 22.4 16.8 8.4 11.2 56 OUT M L 4 CXS 6 21.7 18.6 15.5 12.4 9.3 4.6 6.2 31 IN 110 94.2 78.5 62.8 47.1 31.4 157 OUT 15.7 M L 6 CXS 10 70.0 60.0 50.0 40.0 30.0 20.0 100 IN 10.0 247 212 177 141 106 70.6 353 OUT 35.3 M L 8 CXS 15 176 151