(n 2) (n = 4, 6) Note 4) Rail mounting D-A7mH D-A80H 5 10 15 + 15 (n 2) (n = 4, 6) Note 4) D-A79W 10 15 10 + 15 (n 2) (n = 4, 6) Note 4) D-F7m D-J79 5 5 15 + 15 (n 2) (n = 4, 6) Note 4) D-F7mV D-J79C 5 5 10 + 10 (n 2) (n = 4, 6) Note 4) D-F7mW/J79W D-F7BA/F79F/F7NT 10 15 15 + 20 (n 2) (n = 4, 6) Note 4) D-F7mWV D-F7BAV 10 15 10 + 15 (n 2) (n = 4, 6) Note 4)
) Flow rate /min (ANR) 20 100 180 230 260 390 460 660 790 920 1580 1710 0.3 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Effective area (mm 2) Note 1) Flow rate values are measured at 0.5 MPa and 20C.
35C 100 100 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] 0 0 10 20 30 40 50 60 70 Circulating fluid temperature [C] For the high-pressure pump (Option), the cooling capacity decreases by approx. 20 W.
Bore) -F5PSDPC NCDA1 Tie Rod Mounting NBT-150 (1.5" Bore) NBT-200 (2" & 2.5" Bore) NBT-325 (3.25" & 4" Bore) "SC" auto switch CDQ2/NCDQ Direct Body Mount BQ-2 (32/40/50/63/80/100 Bore) Screw & Nut Kit included with cylinder "SC" auto switch CDRA1 Rail Mounting P294020-24 Screw & Nut Kit for 2 Auto Switches (50/63/80/100 Bore) -F7PSAPC -F7PSC CD85-A Rail Mounting BQ-1 (8/10/12/16/20/25 Bore
(mm) ASG32F-01 4 ASG42F-02 6, 8 ASG52F-03 6 ASG62F-04 Sealant: Special FKM Seat ring: Stainless steel 303 8 12 4, 6 8, 10 10, 12 460 790 920 1580 100 180 230 390 Flow rate (l/min (ANR)) Controlled (free) flow 7 12 14 24 1.5 2.7 3.5 6 Effective area (mm2) Applicable tubing materials Note) Flow rate is measured at 0.5 MPa and 20C.
Use formula (2) for vane type sizes 50, 80, 100 and the rack-and-pinion type. P + 0.1013 0.1013 P + 0.1013 0.1013 QCR = 2V x x 10-3.
Sensor Specifications 23 Chapter 6: Model 6-1. Hyrodless Monosashi-kun With Brake 24 6-2. Controller 24 6-3. Extension Cable 25 Chapter 7: External Dimension Drawing 7-1. Hyrodless Monosashi-kun 26 7-2. Controller 27 7-3. Extension Cable 28 Chapter 8: Part Identification 8-1. Hyrodless Monosashi-kun With Brake 29 8-2. Controller 29 Chapter 9: Installation & Wiring 9-1.
LG1H/ Aluminum body LG1TH/ Stainless steel body LJ1 LG1 LC1 LX LC6D/LC6C Switches 50 10 10 50 Horizontal load 100% Horizontal load 50% 20 10 20 10 Horizontal load 100% Horizontal load 50% Amount of deflection m Amount of deflection m 500 1000 1000 500 200 100 200 100 50 20 50 20 10 10 5 5 Lateral load 100% Lateral load 100% 0.5 1 2 0.5 1 2 Lateral load 50% Lateral load 50% Horizontal empty
temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0 to 1 MPa 0 to 101 kPa 100 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 101 kPa 0 to 101 kPa 101 to 101 kPa 0 to 101 kPa 100 to 100 kPa Set pressure range 12 to 24 VDC (Ripple p-p 10% or less) Voltage 2% F.S. or less (0 to 50C: based on 25C) 3% F.S. or less
6 !4 @4 #3 !8 #7 #8 o #6 q #9 y i $2 @3 @2 #1 @6 #4 #5 Component Parts Note Anodized Nickel plated Chromated Note No.
Flow Rate and Sonic Conductance AS121F-M3 AS121F-M5 AS131F-M5 AS221F-01 AS231F-01 AS221F-02 AS231F-02 AS321F AS331F AS421F AS431F AS131F-M3 Model AS121F-M5-02 2, 3.2, 4 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Metric size Tubing O.D. 1/8" , 3/16" 1/8" , 5/32" 1/8" , 5/32" 3/16" , 1/4" , 1/4" , 5/16" , 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 1/4" , 5/32" 5/16" 3/8" Controlled
L L 2 . 3 . 6 4 . 5 . 6 . 2 2-3. 1 2 Nm mm 16 5 20 M30.5 0.59 6 25 6 8 32 40 M40.7 1.4 8 10 50 63 M50.8 2.8 10 80 M61 4.8 12 100 M81.25 12 16 125 M101.5 24 20 3 P9P11 7 Nm mm MHSH(J)3-32DA,B M30.5 0.6 6 40DA,B M50.8 2.8 10 50DA,B M61 4.8 12 63DA,B M81.25 12 16 80DA,B M101.5 24 20 A J/ / 8 MHS2 Nm mm MHS2-16D M40.7 2.1 8 20D M40.7 2.1 8 25D M40.7 2.1 8 32D M50.8 4.3 10 40D M61 7.3
Relationship between the kinematic viscosity 50 0 1 2 3 4 5 10 20 30 40 50 100 Viscosity (mPas) Transfer is possible up to about 100 mPas.
Use Pn008.1 to activate or not the warning detection. 6.
Address setting switches 1, 2 and 3 ( SW1, SW2 and SW3 ) OFF N.C ON OFF ON With bus terminator Without bus terminator Without bus terminator OFF OFF ON OFF OFF ON OFF OFF ON SW3 1 1 2 100 10 SW3 SW2 0 1 2 9 8 7 6 SW2 3 4 5 0 1 2 0...9 SW1 0...9 9 8 7 6 SW1 3 4 5 0 1 2 1 Common to EX500-S 01/EX500-Q 20 21 Note1: For wiring method, refer to subsection "Wiring" ( page 10 ) of section "EX500"
4 2 5 A 10 x 8 3/4" x 5/8" 5 1 5 B 19 x 16 1/2" x 3/8" 5 2 6 A 12 x 10 1" x 7/8" SMC 6 1 6 B 25 x 22 3/4" x 5/8" 6 2 19 x 16 : Basic size : With reducer Note) Please select an isometric fitting with the same size as the fitting at the flow sensor.
Coil rated voltage CE-compliant Nil Q CE-compliant Nil Q 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz 1 2 3 Note 1) 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only Note) Electrical entry: D or DZ only 4 Note 1) 4 Note 1) 5 6 Note 1)
Standard stroke 6 10 15 20 25 32 40 50 63 6mm 10mm 15mm Port thread type 20mm Bore size 6, 10, 15 Type M thread Rc NPT G Symbol 25mm 32mm Nil 20, 25, 32, 40 40mm TN TF 50, 63 50mm 63mm Standard Stroke Bore size (mm) Standard stroke (mm) Maximum available stroke (mm) 300 50, 100, 150, 200 6 500 50, 100, 150, 200, 250, 300 10 15 20 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 1000 1500 100
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.