SMC Corporation of America
Elite Part Number Search
Search Results "NCDJPL10-037D-B-90"

Description VH300 244120 244120-1 VH400 244219 244219-1 VH600 Resin e Slide ring 24408-1 24077 JIS B 2401 P5 JIS B 2401 P42 24403 24416-3 240359 JIS B 2401 P10 JIS B 2401 G55 24413 2407102A (2407114A) 24425-6 240359 JIS B 2401 P10 JIS B 2401 P71 24413 2407102A (2407114A) 240417 24047 JIS B 2401 P15 JIS B 2401 G120 r t y u i Slide ring spring Check ball spring O-ring O-ring Handle head Piano

B to Nominal filtration accuracy of 5, 10, 25, 50, 100 m can be selected.

AREA A position 2 The AREA signal is output commonly for the ranges set for both the AREA A and AREA B. AREA B Set as AREA 1 AREA 2. position 1 AREA B position 2 48 - Data (Saved data) Data is sent as hexadecimal numbers.

Flow characteristics Operating pressure range (MPa) Weight (g) 4/2 5/3 (A/B R1/R2) Port size 1 4/2 (P A/B) Valve model C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.12 0.10 0.10 0.10 0.12 0.37 0.33 0.34 0.38 0.12 0.43 0.40 0.40 0.35 0.54 0.12 0.19 0.09 0.11 0.14 0.37 0.10 0.30 0.11 0.10 M5 x 0.8 0.45 0.84 0.38 0.48 0.63 VK3120 Used as a 3 Port Valve 1 8 Body ported 90 VK3120Y (For

C.O. 1 2 1 4.1 4.2 Normally closed Normally open Double acting VNB0 VNB02 VNB03 VN 1 4 7.7 7.8 40 12 (P1) 12 (P1) 10 (P2) LVC 6.3 6.4 2 Air operated LVA 2 (B) 1 (A) 2 (B) 1 (A) 2 (B) 1 (A) 11.4 11.5 50 10 (P2) Note) The flange should be JIS B 2210 10K (ordinary style) or its equivalent.

-LD Piping port P Operating direction A 7 Piping port P Operating direction B W K G With switch rail Q + Stroke Z + Stroke Piping port P (plug) Operating direction B HS CR HR Plug 22 8 Piping port P Operating direction B Piping port P (plug) Operating direction B 8 Piping port P Operating direction A 16 19.5 16 Plug REBR15 REBR15 (mm) A B C CB CR D F G GP GW H HA HB HC HP HR HS HT Model REBR15

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.

0 C +0.5 0 4-Rc 1/4, 3/8 4 (B) B 0.1 Max. panel thickness D (mm) A 3.2 3.2 3.2 Model B 40 51 64 C 35 41 51 D 3.5 6 8 VH200 VH300 VH400 3.6-12 Series VH Panel Mounted/Dimensions VH41l-02 to 04 VH41l-06 2 (A) 4 (B) 4 (B) 2 (A) 25 25 3 (R) 1 (P) 3 (R) 1 (P) 107.5 19 l102 102 89 88 4-6.6 4-6.6 88 81 94 148 144 97 97 67 1.5 65 1.5 125 123 105.5 3 (R) 3 (R) 1 (P) 1 (P) 25 17 2 4-Rc1/4, 3/

Peltier-type Chiller Thermo-con/Rack Mount Type Air-cooled Water-cooled Reduced by approx. 90% (UL Standards) Exhaust heat 2500 W The water-cooled type has been added. (800 W, 1.2 kW) Exhaust heat 250 W RoHS Reduces the amount of exhaust heat by 90% Suppresses rises in the ambient temperature 1.2 kW type Water-cooled 1 kW type Air-cooled Space-saving design with reduced height 267 mm 221

5-2.Dimensions C E C E E (KF flange) Fd (K flange) Fn D H B A G A Unit: mm Model A B C D E Fn Fd G H XLA-16-2 40 108 38 20 30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.

M5 x 0.8 b Cv b Cv VV3Z1-01-1 VV4Z1-20-1 1/8 How to Order Manifold Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model no.

Switch operating range Stroke (mm) 20 41 29 47 35 Type 25 46.5 34.5 30 55 43 10 31 19 15 36.5 24.5 A B A B A B MXP10 Auto switch MXP12 3 Screwdriver (Grip diameter 5 to 6mm) MXP16 2 Color indication solid state switch D-F9BW(V), D-F9NW(V), D-F9PW(V) mm Switch operating range Stroke (mm) 20 42 28 48 34 Type 25 47.5 33.5 30 56 46 10 32 18 15 37.5 23.5 A B A B A B MXP10 MXP12

H (Conduit terminal: T) I (DIN terminal: D) Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S T U Model VNA2-10A VNA2-15A VNA3-20A VNA4-25A 3 8 1 2 3 4 63 144.5 55 125.5 52 42 26 29 4.5 14 24.3 72.5 2.3 80.5 25 75 34 80 84.5 124 135.5 151.5 137 153 156 172 60.5 73 1 80 90 62 72 50 60 31 36 35 40 5.5 6.5 17.5 20 28.3 33.3 84 100 2.3 2.3 92 108 30 35 84 90 43 49 89 95 93.5 99.5 Port

Formula for Obtaining the Set Value Set value (Threshold value) Hysteresis value P_1(P_2) = A (A-B)/4 H_1(H_2) = (A-B)/2 n_1(n_2) = B + (A-B)/4 A: Maximum pressure value in auto preset mode B: Minimum pressure value in auto preset mode B Display value fine adjustment function (F6) Fine adjustment of the indicated value of the pressure sensor can be made within the range of 5% of the read

Description Qty Applicable model Anti-quake bracket A Anti-quake bracket B 2 2 4 4 HRR012/018-A/W-10/20-Y HRR-TK001 Nut (M8) HRR024/030-A/W-20-Y Bolt (M8) Mounting of anti-quake bracket 1. Remove the cap from M8 stud bolt. (4pcs) 2. Mount the anti-quake bracket A. (Recommended torque : 12.5Nm) 3. Mount the anti-quake bracket B.

Enclosure Based on IEC529 Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20C, at rated voltage, without surge voltage suppressor.)

25 25 25 4 (B) 1 (P) 3 (R) 74 1 (P) 62 62 49 2 (A) 45.5 46.6 49 62 125 134 94 97 92 73 106 1 (P) 88.5 23 3 (R) 1 (P) 3 (R) 12 12 27 4-1/4NPT 13.5 4-1/4,3/8NPT VH32 -N02/N03 (Bottom porting) 2 (A) 44 3 (R) 1 (P) 4-1/4,3/8NPT 4 (B) 5 Series VH Body Mount/Dimensions (mm) / Body mount type Dimensions VH40 -N02/N03/N04 VH40 -N06 Scale: 35% 4 (B) 2 (A) 4 (B) 2 (A) 25 25 1 (P) 3 (R) 1 (P) 3 (R

VP3185-DZA1-X81 Max.10 (6) 151.8 SYJ 140 87.4 VQZ 26.5 56 B A VP 76 81 105 Manual override (Non-locking) VG VP3 VP3 Applicable cable O.D. 4.5 to 7 Pg9 2 x 1/8 (Pilot EXH port) 1/4 (External pilot port) 2 x 13 (For mounting) PE PA 251.5 242.5 202 158.5 166 150 140 105 90 IN EXH OUT 62 62 1 1/4, 1 1/2, 2 (IN, OUT port) 22.6 (Guide) 2 (EXH port) 41 41 118 In the case of B spec. of -X81 (N.O