Leave it blank for 0.5 m. Select “L” for 3 m or “Z” for 5 m.
Refer to “Lead wire length indication” in the “Auto Switches Common Specifications” section in the catalog, which can be found <a href="/assets/support/faq/en/images/pdf/M-03-3C-04-E.pdf" target="_blank">herea>.
Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.
Normally open Normally closed Polycarbonate AD52 -A AD51 -A Nylon AD52 -6-A AD51 -6-A Metal AD52 -2-A AD51 -2-A 1 Enter the piping thread type to of the bowl assembly part number. Nil: Rc thread, N: NPT thread, F: G thread Please consult with SMC separately for psi and F unit display spccifications.
A B Hs A B Hs Hv Hv Hv Hv 12/16/20 12/16/20 Hs Hs 25/32/40 25/32/40 Proper Auto Switch Mounting Position Solid state switch Bore size (mm) 2-color indication solid state switch Reed switch D-A9 D-A9V D-M9 D-M9V D-F9W D-F9WV A B C A B Hs Hv A B A B Hs Hv A B C A B Hs Hv C 15.5 15 20 20 15 19.5 19.5 19.5 19.5 46 46 46 46 18 13 15.5 35.5 42 31.5 42 31.5 12 17 17 22 22 17 21 21 21 21 47.5 47.5
Skip valve function Combination of 2 or more valves of VNA series provides a skip valve function. Connect the skip valve to the A port side of a stop valve.
LQ2 fittings A port (IN) Applicable tubing size Body class Connecting tubing O.D. Symbol 2 3 4 Metric sizes 04 06 08 10 12 4 x 3 6 x 4 8 x 6 10 x 8 12 x 10 Symbol B A Inch sizes Basic size With reducer 03 05 07 11 13 1/8" x 0.086" 3/16" x 1/8" 1/4" x 5/32" 3/8" x 1/4" 1/2" x 3/8" Note 1) Applicable fittings: LQ2 Note 2) For details of the applicable tubing sizes, refer to page 945.
Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. SET button Press this button to change the mode and to set a value.
Units display (Instantaneous flow) Units display (Accumulated flow) Maintenance Units display (Instantaneous flow) Units display (Accumulated flow) IO-Link specification CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
When tightening the air inlet and outlet piping, make sure to use a pipe wrench to hold the inlet and outlet nozzles of the product. 2. Connect a drain pipe because drainage is created when the compressed air is cooled. 3. The drain pipe must have a minimum pipe bore of 10 mm, and a maximum length of 5 m (when installing an optional auto-drain).
Lubrication Free Mounting position Body ported Impact/Vibrarion resistance (m/s2) (1) 300/50 Note 1) Impact resistance: Nomalfunction resulted from the impact test using a drop impact tester.The test was performed on the axis and right angle directions of the main valve and armature, when pilot signal is ON and OFF.
Flow Rate Range: 10~100 l/min, Thread: Rc, Port Size: Port Size 3/8, Output Specification: NPN Open Collector 2 Outputs, Wiring Specification: w/o Lead Wire, Unit Specification: Fixed SI Unit, Option: -
Flow Rate Range: 20~200 l/min, Thread: Rc, Port Size: Port Size 3/8, Output Specification: PNP Open Collector 2 Outputs, Wiring Specification: w/o Lead Wire, Unit Specification: Fixed SI Unit, Option: -
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [3/8] 3/8, Pressure Resistance(MPa): 1, Number of Outputs: 2, Analog Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: [Resin] PBT, Display: -, Protection Structure: IP65, Unit Specifications: SI unit fixed, Lead Wire: Lead wire with M12 connector 3 m,
Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [3/8] 3/8, Pressure Resistance(MPa): 1, Number of Outputs: 2, Analog Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: [Resin] PBT, Display: -, Protection Structure: IP65, Unit Specifications: SI unit fixed, Lead Wire: Lead wire with M12 connector 3 m,
/ Pulse, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [3/8] 3/8, Pressure Resistance(MPa): 1.5, Number of Outputs: 2, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: [Resin] Resin, Protection Structure: IP65, Unit Specifications: SI unit fixed, Lead Wire: Lead wire with M12 connector 3 m,
/ Pulse, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [3/8] 3/8, Pressure Resistance(MPa): 1.5, Number of Outputs: 2, Power Supply Type: DC, Power Supply Voltage(V): [12 to 24] 12 to 24 ±10%, Liquid contact parts material: [Resin] Resin, Protection Structure: IP65, Unit Specifications: SI unit fixed, Lead Wire: Lead wire with M12 connector 3 m,
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)