kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Maximum load current 500 mA AC/DC (resistance load) Minimum load current 5 VDC 10 mA Output voltage 24 VDC 10% 500 mA MAX (not usable for inductive load) Contact output signal To the thermo-chiller Users equipment side 7 24 VDC 6 24 VDC output (500 mA MAX) 5 15 14 24 VCOM output 13 24 VCOM Signal description Default setting

Electric Slide Table/Compact Type Step Motor (Servo/24 VDC) Servo Motor (24 VDC) LES8, 16, 25 Series LES RoHS How to Order S 1 1 R J 6N LES 8 30 q w e r t y u i o !0 !1 !2 !

Operating voltage range 21.6 to 26.4 VDC Rated input current 5 mA TYP Input impedance 4.7 kW Input signal Rated load voltage 48 VAC or less/30 VDC or less Max. load current 500 mA AC/DC (Resistance load) Min. load current 5 VDC 10 mA Output voltage 24 VDC 10% 200 mA MAX (No inductive load) Contact output signal Product side Customer system side 1 Contact input signal COM 1 k 2 Contact input

E2E-X2D1-N Model Output type Normally open Power supply voltage (Operating voltage range) 12 to 24 VDC (10 to 30 VDC) Ripple 10% or less (P-P) Current consumption (Leakage current) 0.8 mA or less Response frequency 1.5 kHz Control output (Chest) 3 to 100 mA Operation indication (Red LED), Set operation indication (Green LED) Indicator LED RSQ Ambient temperature 25 to 70C (No freezing) Operating

(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

74 9.3 17 32 74 CRBU2 1.5 MPa Allowable surge pressure CRB1 Within 1 Backlash (2) + 4 0 MSU Tolerance in rotating angle Note 1) Output under the operating pressure of 0.5 MPa.

Problem Problem possible causes Investigation method Countermeasures Check that the power supply voltage is within the range 12 to 24 VDC 10%. Incorrect power supply Supply the correct voltage of 12 to 24 VDC 10%. Check the wiring to the power supply.

Step motor (servo/24 VDC) and servo motor (24 VDC) specifications with the following model number are not compliant with UL Standards: Controller/Driver type: Without controller/driver (Nil). Individual actuators are not certified as UL Standards compliant products. 7.

Check that 24 VDC is supplied to the EMG terminal. If it is not energized, the servo will be OFF and does not operate. Stop command Supply 24 VDC to the EMG terminal. Check that the PLC connected to the controller is operating correctly. Check the operation of a single actuator of the controller with a test run.

[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.

13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 Revision history G: Revise Safety Instructions.

Wiring of cables / Common precautions . 32 6. Electric actuators / Common precautions . 33 6.1 Design and selection . 33 6.2 Mounting . 34 6.3 Handling . 35 6.4 Operating environment . 36 6.5 Maintenance . 37 6.6 Precautions for actuator with lock . 37 7.

EMG+ 1 EMG+ 1 EMG2 EMG2 SD+ 3 SD+ 3 SD4 SD4 EN_SW+ 5 EN_SW+ 5 ON 6 ON 6 DC24V 7 DC24V 7 GND 8 GND 8 Shield Shield 32 - 9. CN2: TB/PC connector 9. 1 How to use This connector is for setting the controller (LEC) which is connected to the gateway unit by the teaching box or the set software.

Electric actuators / Guide rod Slider Common precautions . 32 6.1 Design and selection . 32 6.2 Handling . 32 6.3 Mounting . 33 6.4 Precaution on maintenance . 34 7. Troubleshooting . 35 LEL Series / Guide rod Slider Safety Instructions These safety instructions are intended to prevent hazardous situations and /or equipment damage.

Low Voltage Directive This directive is applied to products, which operate above 50 VAC to 1000 VAC and 75 VDC to 1500 VDC operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/L.

Compact Cylinder with Solenoid Valve/ Guide Rod Type 32, 40, 50, 63 Series CVQM How to Order CVQM 32 30 M9BW 5 M Port thread type 32 40 M5 x 0.8 Bore size 32 40 50 63 Nil 32 mm 40 mm 50 mm 63 mm Rc G NPT 50 63 F N Piping Nil P Standard Axial Cylinder stroke (mm) Refer to the next page for Standard Stroke and Intermediate Stroke.