0 100 200 300 400 500 280 560 Data 10 4 8 7 6 5 MXY12 3 2.0 Shock absorber Rubber stopper screw 2 4 Load weight W kg 1.5 Metal stopper screw 3 1.0 1 100 50 200 300 400 560 2 100 50 200 300 400 500 Average speed Va mm/s Collision speed V mm/s 0.5 Average speed Va mm/s 0.0 Collision speed V mm/s 0 100 200 300 400 500 280 560 Note) Use the average speed when calculating static moment.
CRJ U 05 90 E F9B S With external stopper Number of auto switches Nil S 2 pcs. 1 pc.
Note) ;in the table indicates the pad material "N, S, U, F, GN, GS." Note) ;in the table indicates the pad material "N, S, U, F, GN, GS." Note) ;in the table indicates the pad material "N, S, U, F, GN, GS."
Max. operating pressure 0.05MPa Min. operating pressure CJ1 Without auto switch: 10 to +70C (No freezing) Ambient and fluid temperature With auto switch: 10 to +60C (No freezing) CJP Piston speed 50 to 700mm/s 50 to 1000mm/s +1.4 0 CJ2 Up to 1000 mm +1.8 0 +1.4 0 +1.8 0 Stroke tolerance Up to 1000 mm, Up to 1200 mm Up to 1500 mm CM2 JIS class 2 Thread tolerance Rubber bumper/Air cushion Cushion
The cost effective and clean looking AC series allows you to pick a combination of modular style air preparation equipment that best suits your needs. The series, available in 8 size options to ensure optimum performance, offers energy savings, with higher flow rates. Simple assembly and maintenance reduces downtime. Pressure relief, 3 port valve, Accessory for AC series, Body sizes: 1/8
In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction 2-wire s 3-wire Wiring type NPN PNP Output type 24VDC relay, PLC s s IC circuit, Relay, PLC Applicable load 5, 12, 24VDC (4.5 to 28V) Power supply voltage 10mA or less Current consumption 24VDC (10 to 28VDC) 28VDC or less Load voltage 40mA or less s 5 to 40mA 80mA or less Load current 0.8V or less
OB OL P PA PB PW Q R S T U VA 18 M8 x 1.25 7.5 M8 x 1.25 27 27 40 20 6.6 11 1/8 38 30 104 44 118 86 106 40 13 21.5 9 M10 x 1.5 9 32 32 46 22 8.6 14 1/4 47 40 130 60 146 110 130 50 M10 x 1.5 14 28 39 39 58 22 8.6 14 1/4 55 50 130 70 158 124 142 63 M10 x 1.5 9 M10 x 1.5 WA WB Bore size (mm) VB X XA XB XC XL YY YL Z st25 25
300 mm 300 mm 300 mm 4 s 4 s 6 s 6 s 8 s 0 8 s 0 8 s 2 s 4 s 6 s 8 s 0 2 s 4 s 6 s 8 s 0 2 s 2 s 300 mm 300 mm 300 mm 300 mm 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 0 2000 0 400 800 1200 1600 2000 Installation distance [mm] 0 400 800 1200 1600 2000 Installation distance [mm] 1600 2000 m] Extensive static neutralization area can
(IEC 60417-5032-1) How to see the serial number X S 001 May 2019 X R 001 Year Symbol Remarks Month Symbol Remarks Serial no. 1 o Repeated from O to Z in alphabetical order, with O for January and Z for December 2019 X Repeated from A to Z in alphabetical order 2020 y 2 P 2021 Z 3 Q Fig. 1-1 Position of the product label HRL Series 1.4 Product Label 1-3 HRX-OM-W060 Chapter 1 Safety Instructions
Dimensions (mm) Electrical entry A B C D E G H J Z Model Grommet Conduit DIN connector Conduit terminal Q R S T U V W N X Y VV2CW2 49 20 24.5 28 4.5 38 17.3 34.5 58 22 45.5 44 43.5 46 58 41.5 66 99 77 VV2CW3 57 25.5 28.5 30 5.5 42 19.3 38.5 68 24 55 45.5 53 48 60 51 68 101 86.5 VV2CW4 57 25.5 28.5 30 5.5 42 20.8 41.5 76 26 62.5 47.5 60.5 50 62 58.5 70 103 94 7 Series VCW Dimensions (N.O.)
Etfective Orifice (mm2) NPTF (Base mount type) 1 1 3 02=1h 03 = 3/s I .t 1 30 Q2=1/t 03=9e O4=1/z 1 45 03 =3/8 04=1/z 06=aa (Base mount type) 1 2 02=lL 03 = 3/s 8 4.5 4 ?.
T4 = 0.2 [s] T1 = V/a1 = 200/3000 = 0.067 [s], T3 = V/a2 = 200/3000 = 0.067 [s] T2 = = = 0.133 [s] L 0.5 V (T1 + T3) V 40 0.5 200 (0.067 + 0.067) 200 T4 = 0.2 [s] Therefore, the cycle time can be obtained as follows.
or less IP40 Operating: 0 to 60C, Stored: 10 to 60C (With no condensation) Operating/Stored: 35 to 85%RH (With no condensation) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, in X, Y, Z directions for 2 hrs. each (De-energized) 980 m/s 2 in X, Y, Z directions, 3 times each (De-energized) 3% F .S. or less 1000 VAC for 1 min.
direction for 2 hrs, whichever is smaller. 490 m/s2 in X, Y, Z directions 3 times each 1000 Vp-p, Pulse width 1 s, Rise time 1 ns Note 1) In the case of PF2W711, 3% of F.S. or less (15C to 35C, based on 25C).
ML2B C J G5-S Mounting and Cushion Adjustment Application Relief valve body Relief valve Cushion port Cushion chamber Piston High speed Z-axis (Up to 3000 mm/s, dozens N) CV Cushion Capacity Piping/mounting man-hours are the same as that of the general purpose cylinders.
Z (Example) A80CZ 3m . L (Example) A80CL None ...
R and S (Because S function is also included in R.) S and T (Because S function is also included in T.) Note 2) Voltage symbol 20 (200 VAC) is the terminal block connection as standard. Option S cannot be chosen. Voltage symbol 10 (100 VAC) is the power cable with plug as standard.
Pressure gauge Note 1) FGF 1 X82 B 20 Z 050 1 element included (For coarse filtration) 3/5 elements included (Produced upon receipt of order.) Z X82 FGF 050 Option Note 1) Note 1) Without pressure gauge/Without option: is not required to enter. Example) FGFS1A-20-Z050B-X82, FGFS3B-40-Z050X82 Element/Element-Fixing Component Part No.
L, Z S L, Z S Note ) Thread PB 1 32A 40A 50A AC Flange DC Note) Surge voltage suppressor is attached in the middle of lead wire.
Z S L, Z S Note ) PAX 1 1 4 1 2 PB AC Ordering example (Example) Series VXR21, Rc 3/4, 24 VDC, Conduit terminal (Part no.)