Symbol Nil N F Option Option Symbol Applicable actuation Built-in solenoid valve Air Operated PB1013A Air operated Port size Port size 1/8 Nil B N None With foot With silencer Symbol 01 When option is more than one, suffix in alphabetical order.
Series VR4151/4152 How to Order A 01 5 1 1 VR41 Indicator light 0 No 1 Yes Sub-plate Side piping B A Bottom piping Port size W/o sub-plate 00 Rc 01 1 8 1 8 NPT N01 1 8 G F01 Number of pilot ports Single pilot 2 1 Double pilot Number of ports 5 port 5 Dimensions Side ported Bottom ported Stroke 2 mm Stroke 2 mm Indicator light Indicator light Manual override (Button diameter 3.5) Manual override
IEC 60204-1:Safety of machinery --Electrical equipment of machines. (Part1:General requirements) ISO 10218-1992:Manipulating industrial robots -Safety. JIS B 8370: JIS B 8361: JIS B 9960-1:-((1 :) JIS B 8433-1993: *2) 1 2. 3. 1. 2. 3. 4. -2- LEF Series/ . / *3) *3) 1 1 1 1.5 () -3- 1./ 1.1 (1) -1. No. / 1 1 1 1 I/O (1 ) 1 1 (USB ) 1 -2.
MB1 CA2 CS1 CS2 a (1) BJ-1 is a set of a and b. BJ4-1 (Switch bracket: White) BJ5-1 (Switch bracket: Transparent) (2) BMA2-A(S) is a set of c and d. Band (c) is mounted so that the projected part is on the internal side (contact side with the tube).
/Program No. selection 3 DI2 1 0 1 Program No. 6 DI-1 1 1 0 Program No. 7 1 1 1 Program No. 8 Note. 0: off 1: on Program input 1 PI1 Turn PI1 on to resume the step stopped by the SINK (1) command in the program.
When closed 8.8 When open 22.8 7 Standard Type/Series MHZ2 Finger Position/Options Side Tap Mounting Type [1N1] Through Hole in Opening/Closing Direction [2N2] 4-MM Attachment mounting thread C C B A 4-H Attachment mounting hole S S O O B A Unit: mm Unit: mm Model A 3 4 5 6 Model A 3 4 5 6 B 5.7 7 9 12 C 2 2.5 4 5 MM M2.5 x 0.45 M3 x 0.5 M4 x 0.7 M5 x 0.8 B 5.7 7 9 12 H 2.9 3.4 4.5 5.5 1
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)
Hs Auto switch 24.5 A B 49.5 A 33 B Proper auto switch mounting positions (mm) D-G39 D-K39 D-A3 D-A44 D-H7 D-H7C D-H7W D-H7BAL D-C7 D-C80 D-C73C D-C80C D-B5 D-B64 D-G5NTL D-H7F D-B59W Bore size (mm) A B A A A A A A B B B B B B 16 15.5 7.5 12 14 17.5 12.5 11 19 20 8 4 6 9.5 4.5 25 17.5 13.5 17 7 15.5 19 10.5 14 20.5 7.5 3.5 5.5 9 4 32 20.5 16.5 9 20 18.5 22 23.5 12.5 17 9.5 5.5 7.5 11 6 40
Bit offset Item Notes 0 Distance detection SW1 0: OFF 1: ON 1 Distance detection SW2 0: OFF 1: ON 2 SUP port pressure SW1 0: OFF 1: ON 3 SUP port pressure SW2 0: OFF 1: ON 4 OUT port pressure SW1 0: OFF 1: ON 5 OUT port pressure SW2 0: OFF 1: ON 8 Pressure diagnostics 0: Normal 1: Abnormal 15 Error diagnostics 0: Normal 1: Abnormal 16 to 31 OUT port pressure gauge measurement value 16 bit
HRLE Series HRX-OM-Z015 Chapter 1 Read before using Contents Chapter 1 Read before using . 1-1 1.1 OPERATION MODE AND OPERATION METHOD . 1-1 1.2 CHANGE OF OPERATION MODE . 1-2 1.3 COMMUNICATION TERMINAL BLOCK . 1-3 1.4 OPERATION DISPLAY PANEL FLOW . 1-4 Chapter 2 Contact input / output communication . 2-1 2.1 PRECAUTIONS FOR COMMUNICATION . 2-1 2.1.1 Precautions wiring communication . 2-1
#-E#-### PNP (1 output) + Analogue (1 to 5 V) output type PF2MC7###-##-F#-### PNP (1 output) + Analogue (4 to 20 mA) output type Maximum load current: 80 mA Internal voltage drop: 1.5 V or less E: Analogue output: 1 to 5 V Output impedance: 1 k F: Analogue output: 4 to 20 mA Maximum load impedance: 600 Minimum load impedance: 50 PF2MC7###-##-A/B#-### PNP (1 output) + External input type
Indication Item Setting and selection 1 A contact (normally open) Contact type B contact (normally closed) 1 Alternate Signal form (1) Input 1 Contact input signal 1 Momentary [Off] Disabled [External Switch] External switch signal Signal type [Run/Stop] 1 Run/stop signal [Run] 2 Run signal 1 A contact (normally open) Contact type B contact (normally closed) 1 Alternate (2) Input 2 Contact
T3 Cylinder with by-pass piping component parts No. 1 2 3 4 Quantity 1 1 1 1 Description Part No.
2$1@2@4!7 With rubber bumper: CNGBN $6 $0 $7 #2 #1 #3 #6 #9 y #0 $0 @6 q @3 !0 !1 u #4 $5 !5 !4 @5 #5 CL Long stroke CL1 @8@9 @6$3o$2!3r!6i!9@1!
HS Auto switch Auto switch 12 8.5 24.5 16 A B A B 33 38.2 Auto switch mounting position Auto switch mounting height (mm) (mm) Auto switch model D-C7, C8 D-H7 D-H7W D-H7F D-H7BA D-H7 D-H7C D-H7W D-H7BA D-C7, C8 D-C73C D-C80C D-B5, B6 D-C73C D-C80C D-B5, B6 D-B59W D-G5NT D-H7C D-G5NT D-B59W D-H7F Bore size (mm) A A B A B A A HS HS HS B B B B A 20.5 (28.5) 14.5 (22.5) 17.5 (25.5) 19.5 (27.5)
2.3 2.3 3.2 3.2 AL10 AL20 AL30 AL40 AL40-06 AL50 AL60 M5 x 0.8 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 1 25 40 53 70 75 90 95 Optional specification Metal bowl B 82 121 142 176 176 250 268 Model Metal bowl with level gauge B 162 196 196 270 288 Metal bowl with drain cock & level gauge B 186 220 220 294 312 With drain cock B 85 123 153 187 187 261 279 With barb fitting B 161 195
/D-Y7P(V) D-Y7NW(V)/Y7PW(V)/Y7BW(V) D-Y7BAL BU-1 BU-1 BU-1 BU-1 A B A B
Unit type Compliant sensor 1 2 N P B 1 connector, 2-input type NPN output Replaceable fuse (EX9-FU10) 1 connector, 1 input type PNP output 2-wire type Note) B (2-wire type) is available with 1 connector, 2-input type only.
Quick exhaust Normal operation High speed supply B 1/2 PP PA C D PA PP 1(P) 2 2(A) 1 1/2 PP = approx.
P . 14-20-57 14-20-42 2 Odor Removal Filter Series AMF How to Order AMF150 to AMF850 AMF 250 03 R B Option R IN-OUT reversal direction Body size Bracket Accessory (Option) 150 Standard 1 8 250 Standard 1 4 350 Standard 3 8 450 Standard 1 2 550 Standard 3 4 650 850 B 1 4 B 3 8 04 B 1 2 06 B Nil Nil B Piping port (B dimension) 1 Standard 11 2 Standard 01 B 1 8 02 03 Thread type Nil Rc F G N