(Positioning pin hole) CEP1 CEP1 CE1 Cable end CE2 40 17 Without connector + 0.05 + 0.02 4 depth 4 (Positioning pin hole) ML2B 4 45 4 x M5 x 0.8 Thread depth 10 6 Metal connector M14 x 1 4 x M5 x 0.8 depth 6 (Bottom 4.3 through-hole) 7.5 counterbore depth 4 (500 or 3000) 25 5 Width across flats 8 70 0.5 7 3 10 18f8 6f7 3.8 44 17 27 18 SR3.5 26.6 3 18 M5 x 0.8 13 27 40 17 5 67.5 14.5 4 x M4

MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.

BMG2-012 928 Parallel Type Wide Opening Air Gripper MHL2 1122Dimensions 1122MHL2-10D 2 x M4 x 0.7 thread depth 5 (Mounting thread) D C A B 2 x 4.5 through (Hole for mounting body) 9 +0.025 3H9 0 depth 3 34 When closed E When closed J 4 4 x M4 x 0.7 thread depth 8 (Mounting thread) K cross view (Closed) +0.025 3H9 0 depth 3 +0.043 18H9 0 depth 1.5 44 M5 x 0.8 (Finger opening port) Auto switch

A B M G1/2 IN OUT 2 x M4 x 0.7 Thread depth 8 2 x P Port size L K I F 18 (D) J Conduit U E 280 C (42) 45 23 G1/2 For Heated water/ High temperature oil Full-wave rectifier T A B IN OUT M 2 x P Port size L K F I (D) J (mm) Model Conduit terminal Conduit Grommet Electrical entry Port size P A B C E F I J K L T V 1/4, 3/8 1/2 88 (93.5) 22.5 30 D M T 55.5 (61) U T 49.5 (55) U U 50 20 4.5 5

MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.

MVGQM, MVGQL Common Dimensions ML2B Applicable solenoid valve B C DA G GA H J K L MM ML NN Q R S T V W X YY YL Z Bore size (mm) Standard stroke (mm) TA TB U Over 10 st 10 st C J G5-S 12 6 29 50 13 18 58 39 22 56 2 5 36 40 14 7 12 29 5 48 20 30 16 M4 x 0.7 10 M4 x 0.7 M4 x 0.7 10, 20, 30, 40, 50, 75, 100 16 CV 8 33 54 64 15 22 43 25 62 2.5 5.5 38 42 16 8 13 33 7 52 23 30 18 M5 x 0.8 13 M5

x 0.7 8-32UNC 4-40UNC M3 x 0.5 25 24 5 3 32 31.5 5 to 30 4-40UNC M4 x 0.7 8-32UNC M3 x 0.5 5 to 30 26.5 17 31.5 22 29 28 5 3 38 37 1/4-20UNC M4 x 0.7 6-32UNC M6 x 1.0 5 to 50 32 19.5 42 29.5 36 34 5.5 4 47 45.5 5 to 50 1/4-20UNC M6 x 1.0 M5 x 0.8 10-32UNF 35.5 22.5 45.5 32.5 40 38 5.5 5 52 50.5 Bore size (mm) KB L M N OB Q RA RB T V W KA 12 16 20 25 10 7.1 3.5 15.5 3.5 6.5 7.5 7 4 0.5 14.9

D2) Screw a manual unlocking bolt (a conventional bolt of 25, 32: M3 x 0.5 x 25l or more, 40, 50: M4 x 0.7 x 35l or more) into the lock ring threads as shown above, and lightly push the bolt in the direction of the arrow (rod side) to unlock. 2) Screw a manual unlocking bolt (a conventional bolt of 25, 32: M3 x 0.5 x 25l or more, 40, 50: M4 x 0.7 x 35l or more) into the lock ring threads

Refer to the specifications of actuator for more details. 18 Step Motor Controller (Servo/24 VDC) Series LECP6 Servo Motor Controller (24 VDC) Series LECA6 How to Mount a) Screw mounting (LEC6-) (Installation with two M4 screws) b) DIN rail mounting (LEC6D-) (Installation with the DIN rail) DIN rail is locked.

Mounting screw (LECP2-) (Installation with two M4 screws) 2. Grounding Tighten the bolt with the nut when mounting the ground wire as shown below. Ground wire M4 screw Mounting direction Cable with crimped terminal Tooth lock washer Mounting direction Controller Note) The space between the controllers should be 10 mm or more.

. *5: The cleaning time is approximately 2 seconds. 15 Fan Type Ionizer IZF21/31 Series Dimensions IZF21/31 IZF10/IZF10R Technical Data IZF21-m-m 4 x M4 x 0.7, depth 6 (Female thread mounting) 104 2 x 3.5, depth 1 12.5 35 25 139 155 (10.5) 20 16.6 40 Bracket IZF21-m-mBmm 122 (104) 2 x 25 90 (155) 4 x 4.5 171.5 143 124 107 47 3 x 5.5 2 x 5.5 40 45 30 30 16 IZF21/31 Series Dimensions IZF31-

JSXZ Series JSXM Series Option Replacement Parts C C E J J E IN IN A 2 x Port size 1(IN), 2(OUT) port B B1 A 2 x Port size 1(IN), 2(OUT) port B B1 G G 2 x M thread depth N 2 x M thread depth N WN: M12 connector D K F C J E IN B1 B 2 x Port size 1(IN), 2(OUT) port A G 2 x M thread depth N Glossary of Terms [mm] Size Port size A B B1 C D E F G M N 20 1/8, 1/4 19 43 21 64.3 36 9.5 18 12.8 M4

x 0.7 x 14.5 L (Hexagon bolt) and M4 x 0.7 (Hexagon nut) M3 x 0.5 x 10 L (Hexagon socket head cap screw) 2 x M4 x 0.7 through Steel ball Steel ball (14+ST) (16) 4 2 x M3 x 0.5 through 6 (mm) ST 10 20 30 40 50 14+ST 24 34 44 54 64 17+ST 27 37 47 57 67 49.5+ST 59.5 69.5 79.5 89.5 99.5 61+ST 71 81 91 101 111 Part no.

Body fixed A Maintenance Warning L Model Screw size Max. tightening torque [Nm] A [mm] L [mm] LEFl16 M3 0.6 3.5 20 LEFl25 M4 1.5 4.5 24 LEFl32 M5 3.0 5.5 30 LEFl40 M6 5.2 6.6 31 Maintenance frequency Perform maintenance according to the table below.