Unit switching Real-time switch output ( ) For air Hysteresis mode Display Real-time flow rate l/min Accumulated flow l ON YES CFM x 10-2, CFM x 10-1 ft3 x 10-1 OFF P-1 P-2 High flow rate CFM=ft3/min "P" Window comparator mode H : Hysteresis High Flow Rate Type (For Air) H H Display Real-time flow rate l/min Accumulated flow l, m3, m3 x 103 ON NO OFF P-1 P-2 ft3, ft3 x 103, ft3 x 106 CFM
Type S41 How to Order Applicable solenoid valve Note) SY114SY114ASY124SY124AApplicable blanking plate assembly SY100-77-1A VP SS3Y1 S41 05 M3 S070 Stations A port side VQ 02 M3 M5 M3 x 0.5 M5 x 0.8 2 stations VKF 20 20 stations P R VQZ R port M5 x 0.8 P port M5 x 0.8 A port M3 x 0.5 M5 x 0.8 VZ Note) SY114(A) and SY124(A) cannot be mounted on the same manifold.
Description Each part order comes with two M3 x 8 tapping screws.
Type S41 How to Order Applicable solenoid valve Note) SY114SY114ASY124SY124AApplicable blanking plate assembly SY100-77-1A SS3Y1 S41 05 M3 Stations A port side 02 M3 M5 M3 x 0.5 M5 x 0.8 2 stations 20 20 stations P R R port M5 x 0.8 P port M5 x 0.8 A port M3 x 0.5 M5 x 0.8 Note) SY114(A) and SY124(A) cannot be mounted on the same manifold.
Model/Valve Specifications Av x 10-6m2 Cv converted C [dm 3/(sbar)] b Cv Water, Oil, Steam Air Flow characteristics Maximum operating pressure differential (MPa) Min. operating pressure differential (MPa) 10 10 15 10 15 20 Connection Orifice Max. system pressure (MPa) Weight (g) Model Water AC DC AC DC AC DC AC Air Oil Steam size (mm) Thread VXP2130-02 0.7 0.7 1.0 0.7 1.0 1.0 1 4 740 500
VVZS3000-4-1 VVZS2000-4 14.4 x 12 x 1.2 7.5 x 4.5 x 1.5 VVZS2000-11-n (1) q Description Material Seal B Seal A NBR NBR NBR NBR Carbon steel Carbon steel Note 1) n: Stations Note 2) Manifold block assembly is attached with tie-rod for increasing stations. w e O-ring O-ring r t Tie-rod y Tie-rod for station addition VVZS2000-11-1-1 (2) Assembly part no.
141 43 91.7 76.1 65.3 22 48.1 EXH OUT IN 2 x 1/4 to 1/2 Port size 2 x 1/2 Port size 66 With digital pressure switch: IR32l1 2-0llEl-A 76 48 72.5 53 16 M12 x 1 Mounting hole 2.3 M28 x 1.5 30 141 91.7 76.1 65.3 22 48.1 2 x 1/8 Pressure gauge port EXH OUT IN 66 2 x 1/2 Port size 2 x 1/4 to 1/2 Port size 786 IR1200-A/2200-A/3200-A Series Specific Product Precautions 1 Be sure to read this before
BLEED 2 x 1/8 Pressure gauge port 141 43 91.7 76.1 65.3 22 48.1 EXH OUT IN 2 x 1/4 to 1/2 Port size 2 x 1/2 Port size 66 With digital pressure switch: IR30l1 2-0llEl-A 76 48 72.5 53 16 M12 x 1 Mounting hole 2.3 M28 x 1.5 BLEED 30 141 91.7 76.1 65.3 22 48.1 2 x 1/8 Pressure gauge port EXH OUT IN 66 2 x 1/2 Port size 2 x 1/4 to 1/2 Port size 804 IR1000-A/2000-A/3000-A Series Specific Product
EX250-SAS9 Current consumption in the Output block (Current consumption of one output x Output points) x Output block number = (20 mA x 2 points) x 1 blocks = 40 mA Current consumption of the load connected to the sensor, load connected to the Output block and manifold valve.
How to see the manufacturing code X O 001 January 2019 X O 001 Year Symbol Remarks Month Symbol Remarks Serial no. 2019 X Repeated from A to Z in 1 O Repeated from O to Z in alphabetical order, with O for January and Z for December 2020 Y 2 P 2021 Z 3 Q alphabetical order Fig. 1-4 Position of product label HRS-R Series 1.4 Other Labels 1-5 HRX-OM-W058 Chapter 1 Safety Instructions 1.5 Safety
AC200-230V 50/60Hz 1Ph 9.6A XQ001(MAR.2019) How to see the manufacturing code X Q 001 March 2019 X Q 001 REFRIGERANT R410A(HFC) 0.39kg Year Symbol Remarks Month Symbol Remarks Serial (GWP:2088) no.
+|TV205O-212S-X26 . . ... .1 set (Electro-pneumalic regulator pad no-)Nole2) LThe x is the symbol for mounting. Add the x symbol at the beginning of parl numbers lor electro-pneumalic regulators, etc. to be mounted on the base.
actuation VFN VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 Bore size Series CA1 Pressure 0.5 MPa Load factor 50% Stroke 400 mm Average speed (mm/s) Series 100 40 50 63 80 800 700 600 500 400 300 200 100 Perpendicular, upward actuation Horizontal actuation VZ314--01 (Piping: 6 x 1 m) Speed controller/Silencer AS3301F-02-06/AN110-01 800 700 600 500 400 300 200
(1.8) 14.8 (0.8) 36 (2) 15.3 (0.85) 02 03 VFA5144 2 position single : 0.51 02 03 04: 0.56 34.2 (1.9) 34.2 (1.9) 33 (1.8) 36 (2) 45 (2.5) 52 (2.9) 02 03 04 1 8 3 8 1 2 1 4 , , : 0.52 02 03 04: 0.57 1 8 45 (2.5) 52 (2.9) VFA5244 2 position double 02 03 04 3 8 1 2 1 4 , , Body ported : 0.66 02 03 04: 0.71 VFA5344 -X1 3 position closed center 1 8 34 (1.9) 38 (2.1) 02 03 04 JIS Symbol 3 8 1 2
Applicable blank plate assembly SY100-77-1A P R 20 stations VP 20 R port M5 X 0.8 P port M5 X 0.8 VG VP Note 1) SY113 (A) and SY123 (A) cannot be mounted on the same manifold. S41 Type How to Order Applicable solenoid valve (1) SS3Y1 S41 05 M3 VQ SY114-l SY114A-l SY124-l SY124A-l Stations A port size M3 M5 M3 X 0.5 M5 X 0.8 VQZ 2 stations 02 ... ...
-F VFA3130-02 2 1 4 3 VFA3430-02-X1 5 1 8 VFA3140-02 2 1 4 (2) 3 VFA3440-02-X1 5 VFA3140-03 2 3 8 3 VFA3440-03-X1 5 Note 1) Port size of the exhaust ports on body ported type are all 1/8.
(inch) Model H1 (Width across flats) H2 (Width across flats) T (M) Mounting hole M Min. port size Connection thread R Weight (g) L1 L2 Mounting plate thickness 7 mm or less 30 31 36 3 16 KQ2E07-02 KQ2E05-01 17 17 1 8 28 32.5 35 M16 x 1 17 11.5 14.5 15 14.5 14.5 18.5 M22 x 1 74 M14 x 1 M14 x 1 15 15 16.5 17 18.5 4.6 17 17 19 24 3.5 1 4 1 4 3 8 Applicable tubing 5 16 KQ2E09-03 19 6 3 8 21 KQ2E11
Example) G36-P4-01-X30 Regulator 2 Port Solenoid Valve AR 20 E 02 1 VCA27A S 5 DL 02 4 Q Port size Thread type Voltage CE marked 02 02N 02F Rc 1/4 NPT 1/4 G 1/4 Rc NPT G Nil N F 1 2 3 4 5 6 36 100 VAC 200 VAC 110 VAC 220 VAC 24 VDC 12 VDC 230 VAC Throttle Option (The shape of pressure gauge) Note 2) Nil S B K Without throttle and manual lock With throttle With manual lock With manual lock
Internal Circuit (Brown) +5 V +24 V TD+ TD0 V q w e r VP R x D/T x D-N DGND R x D/T x D-P SHIELD q w e r t OUTPUT Internal circuit COM A +24 V RD+ RD0 V q w e r INPUT GND FG DC-DC converter (insulated) GND +24 V TD+ TD0 V q w e r OUTPUT Power supply for output +24 V 0 V q w COM D Power supply for the input and for the control unit of the Gateway +24 V 0 V q w +24 V RD+ RD0 V q w e r INPUT
M5 X 0.8 SYJA514-01 N.C. Base mounted (With sub-plate) 75 (Without sub-plate 45) Rc(PT)1 /8 4.5 (0.25) SYJA524-01 N.O. SYJA712-01 N.C. Rc(PT)1 /8 9 (0.5) 80 Body ported SYJA722-01 N.O. Base mounted M5 X 0.8 Rc(PT) 1 /8, 1 /4 01 02 01 02 SYJA714N.C. Base mounted (With sub-plate) 130 (Without sub-plate 80) SYJA724N.O.