SMC Corporation of America
Elite Part Number Search
Search Results "VVEX4-2-2-C"

45 80 86 101 35 18 35 36 25 72 17.5 1 88.2 148.5 103.9 45 CCVS02-lG-S 1/2 45 80 86 101 35 18 35 36 25 72 17.5 2 98 148.5 121.8 57 CCVSl1-lG-S M5 X 0.8 5.4 to 7.5 1/2 45 80 86 101 35 18 35 36 25 72 17.5 1 98 148.5 57 88.2 103.9 CCVSl2-lG-S 1/2 45 80 86 101 35 18 35 36 25 72 17.5 1 98 148.5 57 88.2 103.9 CCVSl3-lG-S 1/2 45 80 86 35 36 25 72 17.5 98 57 88.2 CCVSl0-S 3/4 66 107

-2VEX-OMV0001 / *3) 1 1.5 *3)1 1 () [] -3VEX-OMV0001 VEX1 Series / / C-R ( )C-R SDS DC VEX1101, VEX1201, VEX1301 2% () VEX1501, VEX1701, VEX1901 3% AC VEX1101, VEX1201, VEX1301 20% VEX1501, VEX1701, VEX1901 15% (SSR)AC 1) (C-R ) OFF () 2)() P2 N.O.() ZNR 1V 0C () 4 VEX-OMV0001 VEX1 Series / () DC 1(P)2(A) 1 ()ISO VG32 1) 2 ( )ISO VG32 (SDS) M5 1/61/4 11.5Nm ) 2)R,

(Rated voltage 125 V, Plug JIS C 8303, Inlet IEC 60320-C13) *1 Measured with a high pressure probe of 1000 M and 5 pF *2 Measurement value based on a charged plate (Dimensions: 150 mm x 150 mm, Capacitance: 20 pF) as defined in the U.S.

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 Series

Pin Clamp Cylinder C(L)KQG32 Series Compact Cylinder Type 32 How to Order Clamping height LOW type KQG C X2081 B L 32 075 R A L C X2082 KQG C Clamping height HIGH type B L 32 075 R A H C Number of auto switches Nil 2 pcs. S 1 pc.

C (F) note 2 -5~+50 (+23~+122) -20~+60 (-4~+140) Max.

DCDIN No.1 +No.2 1) () 2) 3) , 4) DIN DIN DIN DIN DIN GDM2B 2. 2. 2. 2. 1) 2) 3) Y )0.5Nm15% a b O 1.25 3.5 Y 1.25 4 c 612mm 912mm 1. 2. 3. 3. 3. 3. 3. 1 ) 2) 3) )0.5Nm20% AC100V AC200V DC + DC DC 7 VT315**-OMH0005-A V V V VT315 Series/ T315 Series/ T315 Series/ T315 Series/ 1. 1. 1. 1. 1 1 1 230 1 18VA50Hz 16 P R 2PR 3/8 AC AC100V110V200V220V50/60Hz O P8 4 DC DC12V24V48V100

D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting

50 2-Rc 1/8 Vacuum gauge port IRV3000 IRV3000 54 70 50 66 SMC P K U C S O H L 10.5 x 8.5 2-Rc 1/8 Vacuum gauge port Approx. 130 G 43 74 SET VAC SET Pad side Vacuum pump side 22 Approx. 68 Rc 1/2 2-Rc 1/4, 3/8, 1/2 Connection port 66 2

2 No. Description Note 1 Stud ZK2 2 Strainer 3 Mounting bracket !1 ZQ 4 Lock nut 2 pcs. included for male thread mounting (Not included for female thread mounting) y ZR 5 Lock pin 6 Check valve ZB 7 Lock plate !5 ZA Replacement Parts ZX No. Description Part no.

VK300-82-2-01 VK300-82-2-02 VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 1578

G3/8 15 to 20 G1/2 20 to 25 (2) Insufficient tightening may cause seal failure, or loosen the threads. Precautions for use with non-SMC Caution (1) When using the KFG2H*-C series with tubing other than those from SMC, the products are not subject to warranty. Tube Body 8 - 3.

Symbol Terminating resistance FG FG FG Connector Connector Connector shell shell shell 2201/2W + + + 1 1 1 2 2 2 9 9 9 5 SG 5 SG 5 SG Figure1-1 Communication Connection (RS-485) Host Computer Thermo-con RS-232C RS-232C Symbol Pin No.

-2No.VQ1000V-OMV0001 / / / / 1 1 1 1 1.5 1.5 1.5 1.5 * * * *3) 3) 3) 3) * * * *3) 3) 3) 3) 1 1 1 1 1 1 1 1 () -3No.VQ1000V-OMV0001 VQ1000/2000 VQ1000/2000 VQ1000/2000 VQ1000/2000 5 5 5 5 / / / / 0.1 2 C-R () C-R DC 3 AC 8% (SSR (SSR (SSR (SSR )AC )AC )AC )AC 1) / / / / () 3 (C-R ) OFF 3 2)() 3) AC ,, SSR SSR 1) 2) ,1V -10 EXH Assy ( ( ( ( ) ) ) ) () 3 () 4 No.VQ1000V-OMV0001

Refer to the Specific Product Precautions. 19 26 19 (Through) Note 1) 3 +0.05 0 depth 2 7 3.5 3 +0.03 0 depth 2 13 (Through) Note 1) M 2 x M1.7 x 0.35 thread depth 3.5 8 K 12.5 3.5 Vacuum port M3 x 0.5 Operating port 2 x M3 x 0.5 (Plugged when the product is not a symmetric type.) (Plugged when the product is not a symmetric type.)

operating pressure 250 PSI/1.7 MPa Minimum operating pressure 8 PSI/0.06 MPa Ambient and fluid temperature 40 to 140F / 5 to 60 C Piston speed 2 to 30 in/sec (50 to 750 mm/sec) Lubrication Not required (Pre-lubricated at Factory) Mounting B, C, E Standard Stroke (inch) Mounting Max. stroke as standard Long stroke Standard stroke 1/2, 1, 2, 3, 4, 5, 6 1/2, 1, 2, 3, 4, 5, 6 1/2, 1, 2, 3, 4

Construction and Replacement parts SFD110-C** SFD110-*02* Component Parts No. Description Material 1 Element 2 Cover PBT 3 O-ring HNBR 4 Clean One-touch fittings PP, EPDM, Stainless steel 5 Bracket PBT Replacement Parts No. Description Material Note 1 Bracket set SFD-BR100 With 2 countersunk head screw (M3) 5. Maintenance The element of this product cannot be disassembled or replaced.