Nil Rc NPT G TN TF L H LOW type (60 mm) HIGH type (90 mm) LOW type HIGH type Guide pin diameter For guide pin diameter, refer to Table 1 below. Body shape Guide pin shape R D Round type Diamond type 90 Mounting surface (viewed from top) 60 Dimension Mounting Mounting hole (tap, pin hole) arrangement Symbol Diamond type guide pin diameter is 17.5 or more.
Model HEC002-A5A HEC002-A5B HEC006-A5A HEC006-A5B Cooling method Thermoelectric device (Thermo-module) Radiating method Forced air cooling Control method Cooling/Heating automatic shift PID control 50 to 95F (10 to 35C), 35 to 80%RH (no condensation) Ambient temperature/humidity Circulating fluid Clear water 50 to 140F (10 to 60 C) (no condensation) Operating temperature range Circulating
Heat exchanger Radiating method W Water-cooled Temperature controller 007 B HED C 2 Cooling capacity Communication 003 005 007 A B RS-485 RS-232C 300 W 500 W 750 W Temperature controller Power supply 2 Single-phase 180 to 242 VAC 50/60 Hz 176
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 40 60 30 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N Note 2) F Note 3) Thread type Rc NPT G e + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 5) H Note 4) a Without mounting option
Operating temperature range (C) 5 to 60 The shock absorber service life is different from that of the MY1W cylinder depending on operating conditions. Refer to the RB Series Specific Product Precautions for the replacement period. Technical Data 1351 A
encoder) B Compatible motor type CC-Link direct input type (For absolute encoder) Encoder Capacity 100 W 200 W 400 W 100 W 200 W 400 W Type AC servo motor (S2) AC servo motor (S3) AC servo motor (S4) AC servo motor (S6) AC servo motor (S7) AC servo motor (S8) Symbol C S1 S3 S41 SSCNET III type (For absolute encoder) Incremental S S5 S7 S81 Power supply voltage Absolute 1 2 100 to 120 VAC, 50/60
Power supply Nil Rc F G (With Rc-G conversion tting) N NPT (With Rc-NPT conversion tting) 46 3-phase 460 VAC (60 Hz) Specications 1 When the ambient temperature or circulating fluid temperature is 10C or below, refer to "Operation at low ambient temperature or low circulating uid temperature" (page 14). 2 Use uid in condition below as the circulating uid.
Contact capacity 50 VA AC, 50 W DC 1 2 5 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 24 VDC Pressure gauge for supply pressure Pressure gauge for tank pressure Pilot valve Recommended Equipment AIR BLOW Supply pressure AIR It is recommended to use each mist spray unit type with the mixing valves, magnet holders, branch pipes and nylon tubes listed in the table below.
Note 3) When mounting D-M9 on the cylinder (32 to 63), auto switch mounting brackets (BMG2-012) are necessary. 544 Parallel Style Air Gripper/2-Finger Type Series MHS2 Model/Specifications MHS2-20D MHS2-25D MHS2-32D MHS2-40D MHS2-50D MHS2-63D MHS2-16D Model Bore size (mm) 16 20 25 32 40 50 63 Air Fluid 0.1 to 0.6 0.2 to 0.6 Operating pressure (MPa) -10 to 60 Ambient and fluid temperature
For connector cable of M8 connector, refer to page 4-4-60. Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached. Order them separately, if necessary. (For details, refer to page 4-4-11.) 4-4-6
See Specific Product Precautions. 0.2 GD 0 0 10 20 30 40 50 Operating temperature (C) Port size Model Rated flow (L/min (ANR)) Note 1) Weight 60 80 100 100 100 100 300 400 500 500 35 g 35 g 35 g 35 g 60 g 150 g 190 g 190 g 190 g 260 g 4 (One-touch fittings) 6 (One-touch fittings) 8 (One-touch fittings) Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 8 (One-touch fittings) 10 (One-touch fittings
(mm) 6 x 4 8 x 5 10 x 6.5 12 x 8 Length 20 m roll 100 m reel Symbol 20 100 Color 2.0 TRTU0604 TRTU0805 TRTU1065 TRTU1208 Color Black White Red Blue Yellow Green Symbol B W R BU Y G 1.0 Max. operating pressure 0.0 20 0 20 40 60 Operating temperature (C) 1
DIN connector DIN connector with light A surge voltage suppressor is integrated inside the coil as a standard feature. 2 Made to Order 2(OUT) 1(IN) Made to order specifications (For details, refer to page 235) 22.0 MPa 2 Port Air Operated Valve Specifications Response Time 60 VCH42 (N.O.) VCH41 (N.C.)
Non-contact Gripper XT661 Series How to Order Specications 2A 4A 6A 8A 10A Cyclone type XT661 2A R Outer body diameter (mm) 20 40 60 80 100 Piping port size M5 x 0.8 Rc 1/8 Fluid Air* Outer body diameter: Operating pressure 0.01 to 0.5 MPa 2A 20 mm 4A 40 mm 6A 60 mm 8A 80 mm 10A 100 mm Proof pressure 0.75 MPa Ambient and operating temperature 5 to 60C (no freezing) Direction of whirling
size 2 3.2 3.2 4 4 6 6 8 10 12 Inch size 1/8" 1/8" 5/32" 5/32" 1/4" 1/4" 5/16" 3/8" 0.8 Fluid Air, Nitrogen 0.6 Operating pressure 100 kPa to 1.0 MPa (at 20C) Flow rate (Positive pressure) [L/min] *1 15 45 50 80 100 200 250 450 550 650 0.4 Flow rate (Vacuum pressure) [L/min] 2 5 7 10 10 20 30 70 80 100 0.2 Proof pressure [MPa] 1.5 (at 20C) Operating and ambient temperature range [C] 0 to 60
Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 2.2 to 5.7, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 60 or less ms, Ambient/fluid temp: -10 to +60°C 4/5 PORT SOLENOID VALVE. SUBPLATE, NON PLUG-IN BOTTOM PT. 560.00000 lb. I50.
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JC, ZSE40/50/60 1/8 PORTED, .17196 lb, ModelRated pressure rangeDisplay
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1E, ZSE40/50/60 1 TOUCH FITTING, .36409 lb, ModelRated pressure
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, 1E, ZSE40/50/60 1 TOUCH FITTING, .22266 lb, ModelRated pressure
The ZSE40A(F) is also CE, UL/CSA and RoHS compliant.High precision digital pressure switch w/2-color display , IP65 and RoHS compliant , Capable of copying up to 10 switches simultaneously , 3-step setting , Space saving design w/several piping and mounting variations, SWITCH, VACUUM SERIES, ZSE40/50/60 VACUUM SWITCH, JD, ZSE40/50/60 1/8 PORTED, .17416 lb, ModelRated pressure rangeDisplay