SMC Corporation of America
Elite Part Number Search
Search Results "ISE2-01-55"

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Fluid: air/inert gas, Operating pressure range: 0.15 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal 36.0 (2.0); 2 position rubber seal 39.6 (2.2) 3 position metal seal 19.8 - 36.0 (1.1 - 2.0); 3 position rubber seal 21.6 - 39.6 (1.2 - 2.2), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W: metal seal 12 or less to 55 or less; rubber seal 15 or

Standard parallel type air gripper, Bore sizes from 10mm to 40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, Gripper, MHZ, Parallel Style Air Gripper, GRIPPER, 55 lb

Standard parallel type air gripper, Bore sizes from 10mm to 40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, Gripper, MHZ, Parallel Style Air Gripper, GRIPPER, 55 lb

Standard parallel type air gripper, Bore sizes from 10mm to 40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, Gripper, MHZ, Parallel Style Air Gripper, GRIPPER, 55 lb

Standard parallel type air gripper, Bore sizes from 10mm to 40mm, Double acting and Single acting available, Auto switch capable, Improved rigidity of guide rail, Gripper, MHZ, Parallel Style Air Gripper, GRIPPER, 55 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2Q, VFS4000, 2.71903 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, QE, VFS4000 BASE MT 3/8, 2.81351 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60C, VALVE, NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, RD, VFS4000 BASE MT 1/2, 2.48343 lb

Choose from R(PT), NPT or G(PF) thread styles.Fluid: compressed air, Effective area mm 2 (Cv): male thread style 16 (0.88) - 550 (31); female thread style 12 (0.66) - 55 (3.1), Noise reduction: 35db or more, Oil mist removal: 99.9% or more, Element supply pressure: 0.1MP or less, Ambient and fluid temperature: 5 - 60 C, EXHAUST CLEANER, AIRLINE EQUIPMENT, AMC EXHAUST CLEANER, E7, AMC

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE DBL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2I, VFS4000, 3.96832 lb

10% or less) (With power supply polarity protection)55 mA or less (Not including the current consumption of the sensor)Same as [Power supply voltage]Max. 110 mA (However, the total current for the 4 inputs is 440 mA maximum or less.)1 to 5 VDC (Input impedance: Approx. 800K )No. of inputsInput protectionSwitch output(Real-time switch output, Accumulated switch output)Switch output(Real-time

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL PLUG-IN BASE MOUNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 1.276 lb

/OTHER), 55 lb, ModelOutlet air flow rate (l /min (ANR)Recycled air flow Note) (l /min (ANR)Inlet air flow rate (l /min (ANR)Port size (Nomiral size B)Weight (kg)ID607801959753/425

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to 60 C, VALVE SGL NON PLUG-IN BASE MT, VALVE, VFS4000 SOL VALVE 4/5 PORT, 2D, VFS4000, 1.47211 lb

Fluid: air and inert gas, Operating pressure: 0.1MPa to 1.0MPa, Effective area (Cv): 1.7 to 3.6, Coil rated voltage: 100, 200 VAC 50/60Hz; 24VDC, Response time: 55 or less ms, Ambient/fluid temp: -10 to +60°C, VALVE DBL PLUG-IN BASE MNT, VALVE, VFS4000 SOL VALVE 4/5 PORT, QG, VFS4000 BASE MT 3/8, 3.06521 lb

Please contact us for the latest version.sales@ocaire.com, MANIFOLD BLOCK ASSY, VALVE, VV5Q51/55 NO SIZE RATING, 1.41605 lb

10%, 50/60 Hz10 A5 ARefer to alarm function.RS-232CApprox. 55 lbs (25 kg) (including foot for fixing)Power cable, Foot for fixingCE marking

/OTHER), 55 lb, ModelOutlet air flow rate (l /min (ANR)Recycled air flow Note) (l /min (ANR)Inlet air flow rate (l /min (ANR)Port size (Nomiral size B)Weight (kg)ID40330854151/218.5