SI Unit: TAW (AS-i, 8 In/8 Out, 31 Slave, 2 Power Supply), Input Block Stations: None, Input Block: None, Input Block COM: +COM, Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C8 (ø8 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Specifications: A (+COM), Connector Mounting Position: U Side, Valve Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot Type: None, A, B Port Size: N7 (1/4" One-touch Fitting)
Enclosure: W (IP67), SI Unit: 0 (w/o SI Unit), End Plate Type: None, SI Unit Common: Positive Common, I/O Unit Stations: None, Valve Stations: 4 Stations, P, E Port Location: U (U Side), SUP/EXH Block Assy: Internal Pilot, A, B Port Size: C4 (ø4 One-touch Fitting), Mounting: D0 (DIN Rail Mounting, w/o DIN Rail)
Series: 1 (10-SV1000), Base Type: 16FD, Connector Entry Direction: 1 (Upward), Valve Stations: 04 (4 Stations), P, E Port Location: U (U Side, 2-10 Stations), Pilot Type: Internal Pilot, A, B Port Size: N7 (One-touch Fitting for Ø1/4)
Model: 10S (Side Ported), SI Unit Specification: FB (PROFINET, 16 Outputs, M12 Connector), SI Unit Output Polarity: N (Negative Common), Valve Stations: 4 Stations, P, E Port Location: U (U Side, 2 to 10 Stations), SUP/EXH Block: Internal Pilot, A, B Port Size: C8 (ø8 One-touch Fitting)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: None, Input Block COM: +COM, Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C4 (ø4 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Type of Connector: F (D-sub Connector 25 Pin), Connector Outlet Direction: 2 (Connector Side Direction), Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
SI Unit: ZEN (EtherNet/IP), Input Block Stations: None, Input Block: None, Input Block COM: +COM, Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: C6 (ø6 One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
Stations: 4 Stations, SUP/EXH Block Mounting: U (U Side 2~10 Stations), Pilot: Internal Pilot, A, B Port: N7 (1/4" One-touch Fitting), Mounting Method: D0 (DIN Rail Mount w/o DIN Rail)
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Maximum number of solenoids: 24, Number of connectors: 26, 25, 20, 10 pins, Maximum 20 stations available as standard, 6 port sizes available, Optional DIN rail mount SS5V1 MANIFOLD SV1000. MFLD, PLUG-IN, D-SUB CONNECTOR. VALVE.
Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, D-SUB CONNECTOR, VALVE, SS5V2 MANIFOLD SV2000, UN, SS5V2 BUILT IN FITTING 1/4), 1.54323 lb, Model1, 5, 3(P,EA,EB)4, 2(A,B)bCvbCvSS5V2-10C10C82.10.200.462.40.180.48
Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, D-SUB CONNECTOR, VALVE, SS5V1 MANIFOLD SV1000, UN, SS5V1 BUILT IN FITTING 1/4), .80468 lb, Model1, 5, 3(P,EA,EB)4, 2(A,B)bCvbCvSS5V1-10C8C60.980.260.241.10.350.28
Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, D-SUB CONNECTOR, VALVE, SS5V1 MANIFOLD SV1000, 1N, SS5V1 OTHER SIZE RATING, .80468 lb, Model1, 5, 3(P,EA,EB)4, 2(A,B)bCvbCvSS5V1-10C8C60.980.260.241.10.350.28
Please contact us for the latest version.sales@ocaire.com, MFLD, PLUG-IN, D-SUB CONNECTOR, VALVE, SS5V2 MANIFOLD SV2000, WN, SS5V2 BUILT IN FITTING (>1/4), 0.96452 lb
The use of 34 pin connectors allows up to 16 stations with double solenoids.D-sub connector or Flat ribbon cable, Tie rod base, 3000 series, Number of connectors (D-sub): 25 pins, Maximum number of stations: 20, Number of connectors (Flat Ribbon): 26, 20, 10 pins SS5V3 MANIFOLD SV3000. MFLD, PLUG-IN, D-SUB CONNECTOR. VALVE. SS5V1 OTHER SIZE RATING. 2.53531 lb. 1N.
The use of 34 pin connectors allows up to 16 stations with double solenoids.Tie rod base manifold for SV1000 valve, D-sub connector or flat ribbon cable, Maximum number of solenoids: 24, Number of connectors: 26, 25, 20, 10 pins, Maximum 20 stations available as standard, 6 port sizes available, Optional DIN rail mount 4/5 PORT SOLENOID VALVE. 4 STA. MANIFOLD ASSY, CLEAN ROOM. 406.6 lb.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Series: 4 (10-SV4000), Enclosure: W10S (Tie Rod Base), SI Unit: 0 (W/out SI Unit), Valve Stations: 05 (5 Stations), P, E Port Location: U (U Side, 2-10 Stations), SUP/EXH Block Assembly Specifications: Internal Pilot, A, B Port Size: N11 (One-touch Fitting for Ø3/8)
Series: 4 (10-SV4000), Enclosure: W10CD, Valve Stations: 12 Stations, P, E Port Locations: B (Both Sides, 2-20 Stations), SUP/EXH Block Assembly Specifications: Internal Pilot, A, B Port Size: N11 (One-touch Fitting for Ø3/8)