75 kPa to 0.25 MPa1.4 mm10 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa0 to 50C0 to 50C (with no condensation)20 lFreeIP40 or equivalent34 g (without sub-plate), 42 g (with sub-plate)12, 24 VDC?10% of rated voltageClass B1.5 W(0.06 A)2.5 W(0.1 A)1 W50 dB
75 kPa to 0.25 MPa1.4 mm10 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa0 to 50C0 to 50C (with no condensation)20 lFreeIP40 or equivalent34 g (without sub-plate), 42 g (with sub-plate)12, 24 VDC?10% of rated voltageClass B1.5 W(0.06 A)2.5 W(0.1 A)1 W50 dB
75 kPa to 0.25 MPa1.4 mm10 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa0 to 50C0 to 50C (with no condensation)20 lFreeIP40 or equivalent34 g (without sub-plate), 42 g (with sub-plate)12, 24 VDC?10% of rated voltageClass B1.5 W(0.06 A)2.5 W(0.1 A)1 W50 dB
Body Size: 40, Thread: G, Port Size: 1/2, Option: D + G, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 40, Thread: G, Port Size: 1/2, Option: D + G, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Flow Direction: Right to Left
Body Size: 40, Thread: G, Port Size: 1/2, Option: C + G, Attachment: Pressure Switch, Semi-Standard 1: Metal Bowl w/Level Gauge, Semi-Standard 2: Standard
Body Size: 40, Thread: G, Port Size: 1/2, Option: D + G, Attachment: 3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V, Semi-Standard 1: Metal Bowl w/Level Gauge, Semi-Standard 2: Standard
Body Size: 40, Thread: G, Port Size: 1/2, Option: C + G, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Number of Ports: 3 Port, Piping Direct., Plunger Length: 1 (Side Ported, Short), Body Option: Side Mounting, Port Size: F01 (G 1/8, Side Ported Only), Actuator Type: 35 ( Twist Selector, 3 Position), Suffix: G (Green), Indicator: None
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 3, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.02 to 0.15mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 3, Cable Option: -, Bracket Option: -, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 3, Cable Option: Straight, Bracket Option: Bracket, Control Unit: -, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: NPN Output, Unit Specification: Fixed SI Unit, Stations: 6, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -
Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 5, Cable Option: Straight, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -