AXT510-32A AXT503-23A Flow control interface Pressure gauge G36-10-01 G36-10-01 Model Selection Applicable cylinder bore size: 25 to 125 For model selection, refer to Selecting Electro-pneumatic Proportional Valve on page 14-9-20. 14-9-18 3 5 Port Electro-pneumatic Proportional Valve Series VER2000/4000 How to Order Nil Port size Without sub-plate 02 03 1 4 3 8 F.R.L.
Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 VXA VN LVC How to Order Manifold Base Table (1) Orifice Size LVA Model Orifice size (No.) 2 (3 mm) VXA21 VXA22 3 (4.5 mm) 4 (6 mm) VVXA22 VVXA21 LVH LVD Number of stations 02 2 stations LVQ 10 10 stations Manifold base Manifold type Nil V Common
2 VX3 ) VXA How to Order VN VXH2230 02 1 G LVC LVA Bracket Nil B 3 -B JIS Symbol LVH LVD Valve/Body 0 3 ' +0 Electrical option Nil 3 LVQ S ( L LQ Z + ( Port size 6 ( 2 (-' LVN 02 03 04 6 +" 6 &+$ 6 +! TI/ TIL Electrical entry G 8 PA Rated voltage C ) 2 ! >) +# = 1 >) +# = D 543 PAX T ) 3 >) +# = 6 ( 4 !! >) +# = PB 7 !"
Nil N F Rc NPT G OUT 1 IN Port size Symbol 01 02 03 04 06 Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Voltage 1 2 3 4 36 100VAC 200VAC 110VAC 220VAC 230VAC Orifice size Consult SMC regarding other voltages.
Note 1) How to Order Sub-plate Note 2) VQ4000 Note 3) Electrical entry Port size P S Plug-in conduit terminal Plug lead 02 03 Rc1/4 Rc3/8 Piping B Side piping Note 1) Bottom piping type is applicable to only Rc1/4. Refer to p.1.11-46 for thread standard.
Fluoro rubber is used for the rubber parts of seals How to Order Manifolds -lI O Ozone resistant specifications ilTv2o port size EI 114 {xt 3/8 type How to Order Manifold Assemblies shtionu "o,.,) llTV20-02-3. lset (3 station manifold base part no.) lTV2030-312S-X26 . . .. .. . . l set (Electro-pneumatic regulator part no.)
Accessories oxTl 55-'t 71 TA HowTo Order Manifold Base NVVsF3 Sris '{VF3O@ manitold 8ymbol 02 2 stations 20 2O stations Series NVFSOOO Construction/Parts List I SUP EXH,2 P,E, Douue Solnoid Symbol "'qlb P.E. EXH.T SUP 3 Fotiition qosd Center Maln Pa.ts No.
Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A , C D Z F A 2 C A F A 2 C A F A 2 C A F A 2 C A ) f g k ( s b l t h g i e W ) 7 . 0 ( 4 5 . 1 ) 1 . 1 ( 3 4 . 2 ) 5 . 2 ( 1 5 . 5 ) 5 . 4 ( 2 9 . 9 t e k c a r B P 4 2 B P 5 2 B e g u a G 5 2 O R A N . d t S ) g i s p 0 6 1 ~ 0 ( n o i t p O K50A-MP1.0-N02M K50A-MP2.0-N02M 5 3 O R A N . d t S ) g i s p 0 3 ~ 0 ( How To Order N R NAR 4 25 02
10 (3/8) 0.38 0.43 0.13 10-32UNF JM-02 15 (5/8) 0.38 F ND E B D C Part No Bore Size G H .125 .125 0.38 No5-40UNC 0.56 0.44 NY-P006 6 (1/4) 0.32 0.44 .188 .188 0.56 No10-32UNF 0.94 0.75 NY-J015 10 (3/8) 0.39 0.54 .188 .188 0.56 No10-32UNF 0.94 0.75 NY-J015 15 (5/8) 0.39 0.54 D I M E N S I O N S C L E V I S A N D T R U N N I O N P I N d m t Part No Bore Size D L l .095 0.03 0.018 NCT-P006
I Introduction Table of Contents APPENDIX B ACCESSORIES FOR USE WITH COAST PNEUMATICS' COMPONENTS ELECTRICAL CONNECTORS For switches with .187 quick-connect terminations MANUFACTURER PART NUMBER DESCRIPTION Molex 2191-3 (06-02-3031) 2211 (06-02-3011) 3 circuit connector 1 circuit connector Both use terminal numbers 2176, 2328, 2698, or 2799 For switches with .110 quick-connect terminations
AXT503-23A G36-10-01 AXT510-32A G36-10-01 Flow control interface Pressure gauge Model Selection Applicable cylinder bore size: 25 to 125 For model selection, refer to Selecting Electro-pneumatic Proportional Valve on page 706. 704 Series VER2000/4000 5 Port Electro-Pneumatic Proportional Valve How to Order Port size Nil Without sub-plate 02 03 1 4 3 8 ARJ VER2000 02 Series VER2000 AR425
Model (Standard) Model Pressure range (1) VY1 Indication unit Connection thread Note MPa GP46-10-01 to 02 GP46-10-01 to 02L2 GP46-10-01 to 02L5 0 to 1.0 G 1 8 R MPa 1 4 R PPA Note 1) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Be sure to read the precautions in page 14-11-15 for selection and installation.
Clear Water (as Circulating Water) Quality Standards The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulating type Supply water Influence Item Unit Standard value Corrosion Scale generation p p p p p p pH (at 77F (25C)) 6.0 to 8.0 100to 300 Electrical conductivity (77F) [S/cm] Standard item Reference item Chloride ion (Cl) [mg/L]
RoHS 3-Screen Display High-Precision Digital Pressure Switch: For Air ISE70/71 Series How to Order ISE70 02 M L2 Pressure range Option 3 Symbol Description ISE70 0 to 1 MPa ISE71 0 to 1.6 MPa Symbol Description Nil Operation manual Y None K Operation manual + Calibration certicate Piping specification Symbol Description 02 Rc1/4 N02 NPT1/4 F02 G1/41 T Calibration certicate Option 2 Symbol
ALF400 to 900, ALT-5/-9 Series Operating Pressure Range Tank and line pressure How to Order
BA -32 BA -04 BM1 -01 BM1 -02 BM1 -32 BM1 -04 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
How to Order 10 SY 5 L 5 1 20 01 Clean series Bracket Series Nil: Without bracket F1: With foot bracket A, B port size 3 10-SY3000 5 10-SY5000 Thread piping 2 position single only Coil type Symbol Port size M5 x 0.8 10-SY3000 Applicable series 7 9 10-SY7000 10-SY9000 M5 Standard Nil 1 8 01 10-SY5000 T With power saving circuit (24, 12 VDC only) Actuation type 1 4 10-SY7000 02 02 03 2 position
IEC 60079-10-1: 2008) or Zone 20 (as defined in IEC 60079-10-2: 2009)(Refer to page 40 for details) How to Order SY 53 20 01 5 1 LL 3 Bracket UL/CSA compliant 5 7 9 Series Nil: Without bracket F1: With foot bracket 53-SY5000 Thread type 53-SY7000 Nil F N T Rc Thread piping A, B port size 2-position single only 53-SY9000 G NPT Symbol Port size Applicable series Type of actuation NPTF 01 02
Metering Valve with Silencer Series ASN2 Superior sound reducing performance Over 20 dB at max. flow rate Cylinder speed easily set Shape of needle is the same as that of speed controller Retainer prevents accidental loss of needle Model Model Port size Effective area (mm 2) Weight (g) ASN2-M5 ASN2-U10/32 ASN2-01 ASN2-02 ASN2-03 ASN2-04 M5 x 0.8 10-32 UNF 1.8 1.8 3.6 6.5 16.6 24.5 5 5 17