SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-20-DO-00N"

Claw 1 Claw 2 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Error Name Error Display Error Type Troubleshooting Method [2] Turn the power off and remove the output factor for the over current. Then turn the power on.

Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. This function is to display error location and content when a problem or an error occurs. Error name Error display Error type Troubleshooting method Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Do not hold the bellows. Be sure to only hold the valve during reassembly. Pay great attention to mounting the bellow assembly. Otherwise, the bellows might be damaged. > (Note1) Only when disassembling the XLC, apply a 0.2 to 0.4 MPa of pressure to the closed side pilot port. Do not apply pressure to the XLA during disassembly. necessary. (Ensure there are no fibers or dust.)

Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within IG 60Hz. -6- 6. Maintenance !

Installation Warning (1) Do not drop or apply impact during transportation or installation. Otherwise, the product may be damaged. (2) Do not install in areas of high humidity or high temperature.

Input (Only connector "0") 2 1 2 Input No.1 1 3 Power supply (0 V) 1: Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly inputted the input connector "0". 2: N.C.: Not connected 5 3 4 Input 4 Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids.

Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. EX9-PE1 power input connector No.1 M12 5-pin plug B-code Element No.

Caution Operating Condition (1) Do not use in atmosphere containing corrosive gas, chemicals or exposed to sea water or vapor. (2) Do not use where vibrate or exposed to impact. (3) When heat source exist nearby, protect the regulator from the radiation heat.

Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within 1G 60Hz. ! ! ! ! -6- 7. Maintenance Warning (1) If handled improperly, compressed air can be dangerous.

Warning Environment (1) Do not use in environment where the product is exposed to corrosive gas, chemicals, salt water, water or steam. (2) Do not operate the product in a location where it is subject to strong vibration and/or shock. For vibration, it should be within 1G 60Hz. ! ! ! ! -6- 7. Maintenance Warning (1) If handled improperly, compressed air can be dangerous.

(Outlet flow rate:0L/min) Do not rotate the handle to a pressure If the inlet pressure fluctuation is large, the outlet pressure maybe exceeding the max. set pressure. over the setting range of governor, and that will result in an unexpected accident.

Operating Environment Warning (1) Do not operate under the conditions listed below due to a risk of malfunction. In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. In locations in which salt water, water, or water vapor could come in contact with the equipment.

Do not service or attempt to remove pr confirmed. 3. Do not service or attempt to remove pr confirmed. 3. Do not service or attempt to remove pr 3. Do not service or attempt to remove pr 3.

Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

Precautions Do not turn off the controller for communication while the setting software (ACT Controller) is running. Do not connect or disconnect the cable while the setting software is running. The communication is continuously established while the setting software is running.

Tidy Un-friendly What do you think to the manual presentation? ! ! ! Yes Not too bad Unusable Are the explanations understandable? Which explanation was most difcult to understand: . . ! ! Are there any diagrams which are not clear? Yes No If so,which:. ! ! ! What do you think to the manual layout?

During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 2. Regarding the installation posture, place it perpendicular to the ground, with the zero point on the reading of a pressure gauge facing down. 3.