NCQ8B106-T-PS NCQ8B106-T-PS 106 (1 1/16") NCQ8B150-T-PS NCQ8B150-T-PS 150 (1 1/2") NCQ8B200-T-PS NCQ8B200-T-PS 200 (2") NCQ8B250-T-PS NCQ8B250-T-PS 250 (2 1/2")
NIL IDF 100 F 30 4 W C 5 G Size K Size Air compressor size Note) 100kW 125kW 150kW 100 125 150 P R Note) The value is referential. Confirm the capability of the compressor used.
Long service life (Over 20 million cycles) VHS Max. operating pressure Pilot air pressure Ambient temperature and operating fluid temperature 1.0 MPa 0.1 to 1.0 MPa 10 to 60C (1) Impact/Vibration resistance (m/s2) (3) Lubrication Not required (2) Dustproof (Enclosure class 0) (4) 150/50 Enclosure Note 1) Use dry air to prevent condensation when operating at low temperature.
length (Z) Height(H) Up to 36% reduction MY3A With rubber bumper Height (H) MY1B MY3A/3B MY3B With air cushion Height(H) (mm) Series 16 25 40 63 MY3A MY3B MY1B 27 37 54 84 MY1B With air cushion 37 54 84 116 Up to 53% reduction Max. 53% Weight Overall length(Z+Stroke) Z dimension Weight (kg) (mm) Series 16 25 40 63 Series 16 25 40 63 MY3A MY3B MY1B 0.34 0.87 2.95 8.26 MY3A MY3B MY1B 110 150
MADE IN G IDF100150F i-2 i-6 IDX-OM-U021 i i-3 HFC IDF100150F i-3 i-7 IDX-OM-U021 i i-4 / 1 1.5 () IDF100150F i-4 / i-8 IDX-OM-U021 1 1 1-1 i.2.9 1 2 IDF100F-30 C.RV IDF100F-30-CRV1 IDF 100 F 30 C 1 2 G 3 K 100 125 150 ) 100kW 125kW P 150kW ) R V 30 AC200V(50Hz) AC200/220V(60Hz) 1 C 1 G 2 K 3 P R V 1-1 IDF100150F 1 1 IDX-OM-U021 1 1-2 1-2-1 (C) 1-2-2 G 1-2-3 K
IDFA 100 F 40 C G K 100 125 150 ) 100kW 125kW 150kW ) R V 38 AC380V(50Hz) 40 AC400V(50Hz) C G K R V IDFA100F150F 1 1 1.1 IDX-OM-U022 1. 1.2 1.2.1 (C) 1.2.2 G . 1.2.3 K 1.6MPa 1.2.4 R 30A (IDFA100F, IDFA125F, IDFA150F) 30mA 1.2.5 V ON 1.5 OFF 0.5 IDFA100F150F 1 2 1.2 IDX-OM-U022 1. 1.3 A 3 A IDFA100F150F 1 3 1.3 IDX-OM-U022 1.
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Heat Resistant, Operating Temperature(°C): -10~150, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Without built-in magnet, Port thread
Refrigerant R407C (HFC) Series IDF100FS/125FS/150FS Applicable Compressor Size: 100 kW, 125 kW, 150 kW (Max. inlet air temperature: 140F (60C) (Max. ambient temperature: 113F (45C) RoHS How to Order IDF 30 100 FS Nil C K P R V Nil 1 2 3 Size Size Air compressor size Note) 100 100 kW 125 125 kW 150 150 kW Note) Note that the above values are for reference only.
24.1 MPa) Flow capacity Standard: to 30 slpm HF (Option): to 120 slpm Ni-Cr-Mo alloy internals available for corrosion resistance 100 psig (0.69 MPa) outlet pressure achievable with 80 psig (0.55 MPa) control pressure or less How to Order Port Number q w e r AP10 S FV4 FV4 PA 2PW Option Delivery pressure Specification Standard (Cv:0.09) High flow (Cv:0.15) 6) Code Delivery pressure 7 to 150
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This combination Filter/ Regulator minimizes space and piping by integrating the 2 units into one. Standard features include a relieving regulator, which can be quickly locked by pushing down on the adjustment knob. There are many options, which include gauges, auto-drain, metal bowl and covers, different set pressures, etc. The AW is part of the family of modular air preparation
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length(
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
This is a legacy product. Please contact us for the latest version.sales@ocaire.com