The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis.
The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis.
The series is available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Mounting options include basic, foot, front flange, and double rear clevis.
151 14 20 18 36 10 57.5 195.2 7 11.2 6.6 59 33 158.4 71.5 64 79.5 78 5.5 76.5 8 65.5 54 62 72 40 185 209 10 199 14 22 18 36 10 64.5 215.7 8 14.7 9 71 39 173.4 83.5 79 94 95 6.6 91 9 78 67 76 89 50 202 235 14 221 20 28 22 44 14 76.5 219.2 9 16.2 11 84.5 46 177.4 97 95 109.5 113 9 107 9 91 80 92 108 60 203 238 14 224 20 30 22 44 14 89.5 Dimensions for auto switch model D-F79W. 10-12-25 25
151 14 20 18 36 10 57.5 195.2 7 11.2 6.6 59 33 158.4 71.5 64 79.5 78 5.5 76.5 8 65.5 54 62 72 40 185 209 10 199 14 22 18 36 10 64.5 215.7 8 14.7 9 71 39 173.4 83.5 79 94 95 6.6 91 9 78 67 76 89 50 202 235 14 221 20 28 22 44 14 76.5 219.2 9 16.2 11 84.5 46 177.4 97 95 109.5 113 9 107 9 91 80 92 108 60 203 238 14 224 20 30 22 44 14 89.5 Dimensions for auto switch model D-F79W. 10-12-25 25
*10 *10 *10 *10 *10 *7 For pipe thread type: NPT.
This product Your system Write or read Monitoring 60 sec. time Write or read Monitoring 60 sec. time Passage of 180 sec. Excess at no 60 sec. Broken communicatio wire n monitoring o r time. coming 60 sec. off AL19 Communication error is generated.
S + Stroke ZZ + Stroke (mm) AL Bore size Stroke range 1 2 A GB I J MM P S ZZ K NA C H RA B1 KA D H1 E F GA Standard Long 20 25 32 40 50 63 80 100 35 40 40 50 58 58 71 71 5 5.5 5.5 6 7 7 10 10 24 29 35.5 44 55 69 86 106 7 7 7 9 10 10 10 10 0 0 0 10 10 10 10 10 15.5 19.5 19.5 27 32 32 37 37 13 17 17 19 27 27 32 41 14 16.5 20 26 32 38 50 60 10 (12) 10 (12) 10 (12) 10 (13) 12 (14) 12 (14) 16
Mounting orientation Unrestricted 150/50 m/s2 (2) Shock/Vibration resistance Enclosure Dustproof Grommet, Grommet terminal, Conduit terminal, DIN terminal 100, 200, 24 , 48 , 110 , 220 , 240 Electrical entry DC AC (50/60 Hz) Coil rated voltage (V) 24, 6 , 12 , 48 , 100 Allowable voltage fluctuation 15 to +10% of rated voltage 12.7 VA (50 Hz) 10.7 VA (60 Hz) 7.6 VA (50 Hz) 5.4 VA (60 Hz)
DA N4odels wi function at 10%oitheir maximum rated enerS/ percyce.lilessthan 10%, a snia ler modelshoud bespecned. 2. Prov de a positile stop 3nm before end of stroke in tension and cgr.pression to prevent nternal bottoming. 3.
BDL (108.5) 10 4.6 10 34.3 101 74.5 35 5.5 28.1 12.7 ADDRESS No.
] 1000 32 32 25 25 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circullating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig 9-11 Heating capacity (HRR050-A/W-20-) 9.5.2 HRR050-A/W-402000 2000 Ambient temp Ambient temp 1500 1500 Heating capacity[W] Heating capacity[W] 40 40 32 32 25 25 1000 1000 5 5 500 500 0 0 0 10 20 30 40 0 10 20 30 40 Circulating fluid temperature
This product Your system Broken wire o r coming off AL19 Communication error is generated. 60 sec. Communication error automatic restoration Normal connection 60 sec. Write or read Monitoring time 60 sec. Write or read Monitoring time 60 sec.
(mm) Model CXS25-10 S SS ZZ Z 10 94 118 30 20 104 128 40 30 114 138 40 40 124 148 40 21-/2210-/11-/12CXS25-20 CXS25-30 CXS25-40 CXS25-50 21-/2210-/11-/1221-/2210-/11-/1221-/2210-/11-/1250 134 158 60 21-/2210-/11-/12100 184 208 80 CXS25-75 CXS25-100 21-/2210-/11-/1275 159 183 60 21-/2210-/11-/12858 Dual Rod Cylinder CXSL 1221CXS / 10-/1122Basic: CXS32, CXSL32 10-/11221221S ZZ SS 38 16 14 2
) (n = 2, 3, 4, 5) D-A9mV 5 10 35 10 + 35(n 2) 2 (n = 2, 4, 6) Note 3) 35 + 25 (n 2) (n = 2, 3, 4, 5) Band mounting D-C7m D-C80 10 15 50 15 + 40(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 20 (n 2) (n = 2, 3, 4, 5) D-H7m/H7mW D-H7BA D-H7NF 10 15 60 15 + 45(n 2) 2 (n = 2, 4, 6) Note 3) 60 + 22.5 (n 2) (n = 2, 3, 4, 5) D-C73C D-C80C D-H7C 10 15 65 15 + 50(n 2) 2 (n = 2, 4, 6) Note 3) 50 + 27.5
Lifting head [m] Pressure [MPa] 0.3 30 0.2 Usable range 20 (60Hz) 0.1 10 0 0 0 10 20 30 40 50 60 70 Circulating fluid return port Circulating fluid flow [L/min] Fig. 8-9 Pump capacity (HRS100/150-A/W-20/40/46-) 8.5 Pump capacity HRS Series 8-14 HRX-OM-S004 Chapter 8 Documents 8.6 Types of Hazard Labels (HRS--40/46-) To ensure the safety of the operators, potential hazards are classified and
L=100mm L=100mm MXP10-10 MXP10-20 MXP10-10 MXP10-20 0.04 0.03 0.08 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10-10 MXP10-20 MXP10-10 MXP10-20 Table deflection (mm) Table deflection (mm) Table deflection (mm) 0.03 0.06 0.02 0.02 0.04 0.01 0.01 0.02 0 0 0 80 20 40 60 80 Load (N) 20 40 60 80 Load (N) 20 40 60 100 Load (N) 12 12 12 L=100mm L=100mm L=100mm MXP12-15 MXP12-25 MXP12-15 MXP12-25 0.05
VR2110-01 Model Supply pressure 0.1 to 1.0 MPa Signal pressure 0.25 to 0.8 MPa SA 0.5 to 60 s Time delay Repeatability 10% F.S.
to 100 64 62 53.4 7.5 M6 x 1 32 29.7 8 50 6.6 M8 x 1.25 50 0.2 46 10 to 100 77 74 59.6 7.5 M6 x 1 38.5 35.4 8 60 9 M10 x 1.5 54 Note 1) The dimensions (A + stroke) and (B + stroke) for 5 mm stroke will be the same as those for 10 mm stroke.