SMC Corporation of America
Elite Part Number Search
Search Results "25A-PF3W740-04-A-M"

Series: 25A-ZSE20, Rated Pressure Range: B (0 to -101 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specifications: M (SI Unit Only), Piping Specifications: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-PFM7, Flow Rate Range: 10 [0.2 to 10 (5) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: With Instruction Manual, Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber)

Series: 25A-PFM7, Flow Rate Range: 25 [0.5 to 25 (12.5) L/min], Port Size: C6 (ø6 One-touch Fitting), Piping Entry Direction: Straight, Output Specification: B (2 PNP Outputs), Unit Specification: M (Fixed SI Unit), Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: T (Panel Mount Adapter

Series: 25A-PFM7, Flow Rate Range: 50 [1 to 50 (25) L/min], Port Size: N01 (NPT1/8), Piping Entry Direction: L (Bottom Side), Output Specification: C [1 NPN Outputs + Analog (1 to 5 V)], Unit Specification: M (Fixed SI Unit), Operation Manual: N (None), Calibration Certificate: None, Connector: W (Lead Wire w/Connector, 2 m; Rubber Cover for Connector, Silicon Rubber), Option: R (Bracket

The type without the unit switching function will have a fixed SI unit (l/min, or l, m or m x 10). Output (OUT1) Indicator DOWN Button ( Button) Lights up when OUT1 is ON. UP Button ( Button) Use when decreasing a setting value. Use when increasing a setting value. MODE Button ( Button) SET Button ( Button) Use when changing a function. Use when selecting a function.

O-ring Port plug Body Ported Base Mounted Blanking plug (For One-touch fittings) KJP-02 A L Dimensions [mm] Applicable fitting size d Model A L D Weight [g] 2 KJP-02 8.2 17 3 0.1 3.2 KQ2P-23 16 31.5 5 1 4 KQ2P-04 16 32 6 1 23 KQ2P-04 D Silencer (For manifold EXH port) Body Ported Base Mounted Silencer is installed in the EXH port.

Auto switch model Bore size [mm] 20 25 32 40 D-M9m(V) D-M9mW(V) BM8-020 (A set of a, b, c, d) BM8-025 (A set of a, b, c, d) BM8-032 (A set of a, b, c, d) BM8-040 (A set of a, b, c, d) BM8-025S (A set of a, b, c, d) * S: Stainless steel set screw BM8-032S (A set of a, b, c, d) * S: Stainless steel set screw BM8-040S (A set of a, b, c, d) * S: Stainless steel set screw D-M9mA(V) BM8-020S (A

M/C Makes it possible to monitor the air flow from the main line to each branch line. A COM COM COM B DC12V GND F.G. R.S. HOLD BANK1 BANK2 MULTI COUNTER:CEU5 UP M/C COUNT PRESET FUNC. LEFT RIGHT DOWN SEL.

It is possible to manufacture it with a switch. Note) The -X126 model cannot be manufactured with an L plug connector for electrical entry. Therefore, use a grommet type or an M plug connector.

1 RE A B REC CX CY A A MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC MK(2) RS Q G Enlarged view of A Component Parts RS H A Description No.

Turn cover A counterclockwise until it stops (approx. 45). 4. Install a new element on cover A and insert it into the case. Cover A Case Cover A Case O L L Element O-ring Window 5.

M 3 m L 5 m Z None N Solid state auto switches marked with are produced upon receipt of order.

M 3 m L 5 m Z None N Solid state auto switches marked with are produced upon receipt of order.

Thus, in spite of using pneumatic equipment, it performs similarly to a RE A B REC CX CY MQQ M A selection of valve unit is available to suit your application. High cylinder driving speed.

(1.64 ft) L 3 (m) (9.84 ft) Z 5 (m) (16.4 ft) For standard part number please see applicable auto switches on page 44 50 For standard part number please see applicable auto switches on page 44 50 Connector type A M8-3 pins B M8-4 Pins D M12-4 Pins Lead wire length S 0.5 (m) M 1.0 (m) L 3.0 (m) Auto Switch Mounting Bracket/Part No.

IDX-OM-W026-A / Series IDF22E-20(-A,C,K,L,M,R,T) IDF22E-30(-A,C,K,L,M,R,T) IDF37E-20(-A,C,K,L,M,R,T) IDF37E-30(-A,C,K,L,M,R,T) IDF55E-30(-A,C,L,M,R,T) IDF75E-30(-A,C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC ISO4414 *1) JIS B8370 *2 ) *1) ISO4414Pneumatic fluid power General rules and safety requirements

ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 E A M G 1 ZL3 M 0 1 K1 5 LO Z 1 V A M W 1 1 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 4) 2) 1) 3 300L/min(ANR) M 0.35MPa *2 P 6 600L/min(ANR) H 0.50MPa 3)P V/ *23 (V) (P) 5/ 06 Rc3/4 K1 N.C.+N.C. 8() 04 2xRc1/2 K2 N.C. *1 F06 G3/4 B1 N.0.+N.C. *1 F04 2xG1/2 B2 N.O.

Windows Edition Operating environment Model: LC1-1-W1 A model with a Pentium 75MHz or faster CPU, and able to fully operate Windows 95. Computer Windows 95 16MB or more 5MB of disk space required OS Memory Disk drive Windows is a registered trade mark of the Microsoft Corporation. Pentium is a domestic trade mark of the Intel Corporation.