SMC Corporation of America
Elite Part Number Search
Search Results "AL10-M5-3-A"

Rc, NPT, G 1/4, 3/8 S coupler plug mounting Note 1) VMG12/Piping entry: Top 34.2 Width across flats 22 Rc, NPT, G 1/4, 3/8 Rc 1/4 Nozzle S coupler plug mounting 172.5 147 23 102 30 A 117.5 mm mm A 23.4 23 22.5 22.1 44 44 44 A 12 12 12 12 305.3 305.3 605.3 605.3 Note 1) Note 1) Nozzle size 1 1.5 2 2.5 1 1.5 2 Nozzle size 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 1.5 2 1.5 2 Type Nozzle model KN-R02-100

Through holes Model Bolt Max. tightening torque Nm Body thickness (l mm) LXP M5 x 0.8 4.4 37.5 3. T-slots l Model Bolt Max. tightening torque Nm Max. screw-in depth (l mm) LXP M5 x 0.8 7.4 8.5 Use bolts at least 0.5mm shorter than the maximum screw-in depth, so they do not touch the body.

For example, the bore size to move a workpiece with a weight of 37 kg requires a bore size of 43 or more.

DC+COM A(-) C(+) COM B(-) 1N.C.ON 2 ZNR/ 3AB 23 - No.ZB-OM00301 (10ms ) 1 210ms 2 330m/s 4() A-C ON B-C ON N.C. A-C ON OFF 10msec ON 10 A B OFF 50 A B 10 1 50 3 3 24 - No.ZB-OM00301 ZB / / Assy /HNBR Assy //HNBR 25 - No.ZB-OM00301 2 ()() 5kPa () ZFAZFBZFC ON ZB1-VQ110U N.C (0.3 0.4 0.5 0.6) ZB1-VQ110L (0.30.4) ZB1-VQ120U N.C ZB1-VQ110N.C.

Valve side exhaust 482 Stainless steel High Vacuum Angle/In-line Valve XMA, XYA Series Dimensions XMA/Angle type C D L2 (KF flange) Fn Fd Fc C (Fc) L1 (K flange) (CF flange) H B G A A (mm) Model A 103 113 158 170 196 235 B 38 48 66 79 100 117 C 1 1 2 2 3 3 D 30 40 55 75 87 114 Fn Fd 34 Fc 17 26 41 52 70 83 G 40 39 63 68 69 96 H P.C.D L1 6 x 4.4 L2 XMA-16 XMA-25 XMA-40 XMA-50 XMA-63 XMA-

The pressure difference generated at this time opens check valve and the residual pressure on the A port side is quickly exhausted from R port. 2 1(P) OFF 2(A) 1 3(R) 3 Soft Start-up Valve AV2000/3000/4000/5000 Construction B ON OFF B-B 1(P) 2(A) B 3(R) Parts list No. 1 2 3 Description Material Body Cap Cover ADC ADC ADC Replacement parts Description No. Part no.

A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud. M5 x 10 DIN913-45H VP4 12 2 8 VZS G 1/4 DIN/ISO228/1 M5 Drive flange face VFS VS4 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 VQ7 1.5 3 EVS VFN The solenoid valve can be attached with 2 mounting bolts.

Cylinder ports are NAMUR hole pattern. 3-12-4 5 NAMUR Interface 5 Port Solenoid Valve Series VFN2000N/3000N NAMUR Mounting Pattern Axis A-A' can be aligned to suit. A 24 VK M5 thread 8 deep, with or without insert depending on base material. VZ 32 VF A' VFR Coding stud.

As a rule, they should be tightened 2 to 3 turns with a tool after first tightening by hand. Be careful not to cause damage by over tightening. 1.Tube attachment and removal of One-touch fittings. 1) Installation of tube. 1. Take a tube having no flaws on its periphery, and cut it off at a right angle. When cutting the tube, use tube cutters TK-1, 2 or 3.

3!4!5 Piping port Side table direction A B C Actuating port Left Actuating port Right Brake release port There are 6 actuating ports and 3 brake release ports at head cover WR, and 6 actuating ports on the head cover WL. The most suitable piping position can be selected by choosing each 1 port from A, B, C and combining them.

A 24 V100 M5 thread 8 deep, with or without insert depending on base material. SY 32 SYJ A' VK Coding stud.

Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to a malfunction. 2. The tensile strength of the cord is 20 N. Applying a greater pulling force on it can cause a malfunction. When handling, hold the body of the sensor do not dangle it from the cord. 3. Do not exceed the screw-in torque of 3.5 Nm when installing piping.

thread depth 3.5 Vacuum suction port 35 Note) 11-, 22-: Vacuum suction port 12-, 21-: Relief port ST 61+ST 15 49.5+ST 3.5 8 13 1 M5 x 0.8 x 4 L 4 16 14+ST 4.5 4.5 (Hexagon socket set screw) M8 x 1.25 x 8 L (Bolt holder) 1 40 45 45 3 3 330.2 330.2 330.2 42 20 8 8 6.5 counterbore depth 5.5 (Same on the opposite side) 3.4 through 2 x M3 x 0.5 through 3 3 6.5 45 45 M4 x 0.7 x 14.5 L (Hexagon

VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.

modular type that can easily be mounted in a manifold station.

A 24 M5 thread, depth 8 With or without insert depending on base material. 32 A' Coding stud M5 x 10 DIN913-45H 12 2 8 M5 Drive flange face G1/4 DIN/ISO228/1 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 1.5 IP 3 IW 1301 AW The solenoid valve can be attached with 2 mounting bolts.

VDC Pressure Characteristics Pressure Characteristics 1 i 6 _ 102 9 s 3 o t 5 o 1000 2000 3000 4000 5000 F ow rale f/min(ANBI 20 30 40 200 400 600 400 looo Fow rale i/m n(ANF) 1 3 1 102 e7 T3 d 7 3 58 a a a 29 1 5 1 5 o 4 8 1 2 1 6 2 A 2 4 2 8 400 800 1200 1.in 2004 2400 200 400 600 800 1000 Belief flo\i/ i.

The tensile strength of the power cord is 49 N, and pulling it with a greater force can cause failure. 3. When handling the product, never move or loosen the switch assembly or the switch assembly mounting screws.