SMC Corporation of America
Elite Part Number Search
Search Results "AV3000-03-5GZ-R-A"

Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.

Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.

Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.

Series VQZ base mount solenoid valves combine convenience with durability and performance in a more traditional mounting style. Series VQZ Body Ported Solenoid Valves combine flexibility with high performance and long life in an inline body style.

M E N S I O N S AD S E R I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS

Description AC servomotor Lead screw High rigidity direct acting guide Coupling Bearing R Bearing F Body Table Housing A Housing B No.

NDH10 MM MM MM NDH10 MM L L R1 R1 R1 R R R1 R R E1 E1 E1 E1 U1 NX NX A1 U1 A1 L1 U1 A1 NX U1 A1 L1 NX L1 NZ A L1 A NZ A A ND Part no. Applicable bore size (mm) A A1 E1 L1 MM U1 NX NZ L Applicable A Applicable bore size (mm) MM R1 U1 NDH10 NX R1 R Part no. R pin part no.

-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VX3 L L VXA K VN K Conduit terminal: T LVC LVA F (Q) 34 LVH LVD LVQ 25 U LQ R C LVN G1/2 TI/ TIL E B A H D 2-P Port size (S) PA 2-M Thread depth N PAX L PB K (mm) Electrical entry P Port size B C A D E F H K L M N Grommet:G Conduit:C Conduit terminal:T Model Q R Q R Q R S U 13.5 28 64 1/8 31 6.5

(Values at the initial period) VQZ VZ VS VFN Base mounted Flow Characteristics/Weight Weight (kg) Flow characteristics P A Port size Rc C [dm 3/(sbar)] b Cv C [dm 3/(sbar)] b Cv A E AC 0.34 0.34 0.40 0.40 0.32 Body type Valve model DC 0.46 0.46 0.52 0.52 0.44 VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00 1 8 1 4 1 4 3 8 2.5 3.6 3.2 3.6 0.39 0.34 0.31 0.18 0.86 0.86 0.93 0.94 0.66 0.88

/ Construction 9 5 bn bn 4 8 1 3 2 bs A A' bl bq br bm bt bo bp bk 7 View A-A' 6 Material Note Parts list Material Note Parts list No.

Step 4 Item Selected item Symbol r VXB2 1 5 A H B L L Yes r Indicator For special options, refer to page 5. Step 5 3 Angle Seat Valve / Air Operated Type VXB Series For Steam Can be used with air or water Flow Rate Characteristics N.C.

3 y r t !1 RE A B REC CX CY A A MQQ M Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com RHC MK(2) RS Q G Enlarged view of A Component Parts RS H A Description No.

HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).

Input and output ports are connected by a needle valve r. Adjustment ensures that exact equalization occurs between the signal and output supply. The above function allows a low volume signal to provide high volume output with pressure ratio remaining (1:1) for signal to output. Construction IN w o e y EXH EXH t q r OUT SUP u i Component Parts Replacement Parts No.

Free flow Controlled flow Model Applicable cylinder bore size (mm) Effective area (mm2) Weight (g) Port size Flow rate (/min (ANR)) Flow rate (/min (ANR)) Flow rate (/min (ANR)) AS2000E-01 AS2000E-02 AS3000E-02 AS3000E-03 AS4000E-02 AS4000E-03 AS4000E-04 90 1/8 1/4 1/4 3/8 1/4 3/8 1/2 3.8 250 5.2 340 20, 25, 32, 40 115 12.3 810 12.3 32, 40, 50, 63 810 130 40, 50, 63 80, 100 25.5 1670 25.5

Series AV is a soft start up valve for low-speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply.

For futhr details ol accessorbs. reler lo 'accessorles' on page 6. 4 rP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure differential between the two diaphragms creates a force to open the pilot valve.

For futhr details ol accessorbs. reler lo 'accessorles' on page 6. 4 rP300 METHOD OF OPERATION Signal pressure from a controlled pressure source enters the 1P300 input chamber and exerts a force on the diaphragms. A pressure differential between the two diaphragms creates a force to open the pilot valve.