SMC Corporation of America
Elite Part Number Search
Search Results "AV5000-N06-5D-RZ-A"

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type, Vacuum Pressure Sensor

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Part Number Description: REPAIR KIT FOR XT13-207-N06   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Click here to report information errorImage shown may not match exact part number

Part Number Description: REPAIR KIT FOR XT13-207-N06   Product Line: E   Product Line Description: AIRLINE EQUIPMENT   Click here to report information errorImage shown may not match exact part number

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: N06 [Vacuum: NPT3/4; Supply: 5/16" (Inch)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: E (Push-turn Locking Lever

This may result in a reduction in flatness. Storage Caution When mounting to equipment, use M5 hexagon socket head bolts, and fix the adsorption plate on a surface with a high degree of flatness. Mounting on a surface with a low degree of flatness may result in a reduction in flatness of the adsorption surface. Store in a normal indoor environment.

Size: 50, Thread Type: N (NPT), Port Size: 06 (3/4), Mounting: w/o Mounting Option, Float Type Auto Drain: w/o Auto Drain, Bowl: Sizes 20, 30, 40: Polycarbonate Bowl; Sizes 50, 60: Stainless Steel, Drain Port: w/Drain Cock, Indicator: w/o Indicator, Flow Direction: R (Right to Left), Drain Cock w/Barb Fitting: None, Pressure Unit: Z (Name Plate and Caution Plate for Bowl in Imperial Units

Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 06 (3/4), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature:

Body Size: 40, Thread: N (NPT), Port Size: 06 (3/4), Mounting: w/o Mounting Option, Bowl: Polycarbonate Bowl, Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: R (Right to Left), Pressure Unit: Z ( Pressure Unit: psi; Temp Unit: °F

Body Size: 50, Backflow: K (w/Backflow Function), Thread: N (NPT), Port Size: 06 (3/4), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Knob: Downward, Pressure Units: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)

Body Size: 50, Thread: N (NPT), Port: 06 (3/4), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: RZ (R + Z)