Minimum display unit (Ambient temperature of 25C) Analog output accuracy 0.5% F.S. (Ambient temperature of 25C) Repeatability 0.1% F.S. Minimum display unit Temperature characteristics 0.5% F.S. (Ambient temperature: 0 to 50C, 25C standard) Accuracy Output type Select from NPN or PNP open collector output.
minute between live parts and case Insulation resistance 50 M between live parts and case (at 500 VDC) 10 to 500 Hz at whichever is smaller of 1.5 mm amplitude or 98 m/s2 acceleration, Vibration resistance in X, Y, Z directions, for 2 hours each (De-energized) 980 m/s2 in X, Y, Z directions, 3 times each (de-energized) Impact resistance Temperature characteristics 2% F.S. or less (based on 25C
(Ambient temperature at 25C) Linearity 0.4% F.S. Repeatability 0.2% F.S. Effect of power supply voltage 0.8% F.S.
Trace the arrow mark, starting with F for cooling temperature 25C (pressure dew point 25C) to obtain the intersection G on the pressure characteristic line for 0.7 MPa. From the intersection G, trace the arrow mark to obtain the intersection H on the vertical axis. The intersection H is the amount of water included in the compressed air 1 m3 at 0.7 MPa, pressure dew point of 25C.
Item CH1 CH2 Setting range 15 to 25 20 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.
MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)
MHK2-12S 120 12 9 4 9 13 76 Normally open Normally closed MHK2-16S 16 23 6 14.6 20.6 114 DL1 MHK2-20S 20 34 10 16 26 237 L2 MHK2-25S 25 58 14 19 33 443 20MHK2-12C 12 12 4 9 13 76 MHK2-16C 16 25 6 14.6 20.6 115 MHK2-20C 20 44 10 16 26 237 MHK2-25C 25 73 14 19 33 443 Series MHKL2/Long Stroke Type Note) Width at opening (mm) L2 Width at closing (mm) L1 Effective gripping force per finger (N)
: 80 Internal hold: 86 MHK2-16D 16 6 14.6 20.6 113 MHQ Double acting MHK2-20D 20 10 16 26 235 MHL2 MHK2-25D 25 14 19 33 440 MHK2-12S 120 76 13 9 4 12 9 MHR L1 Normally open Normally closed MHK2-16S 114 20.6 14.6 6 16 23 L2 MHK MHK2-20S 237 26 16 10 20 34 MHK2-25S 443 33 19 14 25 58 Single acting MHS MHK2-12C 76 13 9 4 12 12 MHK2-16C 115 20.6 14.6 6 16 25 MHK2-20C 237 26 16 10 20 44 MHK2-25C
20 10 16 26 8.3 O.D. holding:18.0 (80) I.D. holding :19.3 (86) MHK2-25D 25 14 19 33 15.5 MHK2-12S 120 12 2.0 (9) 4 9 13 2.7 Normally open Normally closed MHK2-16S 16 5.2 (23) 6 14.6 20.6 4.0 MHK2-20S 20 7.6 (34) 10 16 26 8.4 L1 MHK2-25S 25 13.0 (58) 14 19 33 15.6 Single acting L2 MHK2-12C 12 2.7 (12) 4 9 13 2.7 MHK2-16C 16 5.6 (25) 6 14.6 20.6 4.1 MHK2-20C 20 9.9 (44) 10 16 26 8.4 MHK2-25C
) Battery life Response speed 250 ms 2% F .S. or less (Temperatue conditions: at 25C) Display accuracy 1% F .S. or less (Temperatue conditions: at 25C) Repeatability 3% F .S. or less (0 to 50C with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock
(Example) Mass of transferred object: 300 kg, Transfer speed: 20 m/min Friction coefficient: = 0.1 Mass of transferred object m [kg] Friction coefficient RS2H50-30 The graphs indicate the values at normal temperature. (20 to 25C) = 0.1 = 0.2 500 500 Mass of transferred object m [kg] Mass of transferred object m [kg] 50 Operating range Upper limit 400 400 Upper limit 50 Operating range
Item Unit Standard value Corrosion Scale generation pH (at 77F [25C]) 6.0 to 8.0 Tap Water (as Facility Water) Quality Standards Electric conductivity (25C) [S/cm] 100 to 300 The Japan Refrigeration and Air Conditioning Industry Association JRA GL-02-1994 Cooling water system Circulation type Make-up water Standard item Chloride ion (Cl) [mg/L] 50 or less Sulfuric acid ion (SO42) [mg/L
) Battery life Response speed 250 ms 2% F .S. or less (Temperatue conditions: at 25C) Display accuracy 1% F .S. or less (Temperatue conditions: at 25C) Repeatability 3% F .S. or less (0 to 50C with 25C standard) Temperature characteristics Piping port M5 x 0.8 0 to 50C (With no condensation) Ambient operating temperature Ambient operating humidity 35 to 85% RH (With no condensation) Shock
Repeatability ISA2 Hysteresis mode Hysteresis Adjustable (can be set from 0) IS Window comparator mode Display 3 digit, 7-segment indicator, 2-color display (red and green) can be interlocked with the switch output, Sampling cycle: 5 times/s ZSM 2%F.S. 1 digit or less (at 25C 3C) Display accuracy Indication light Light up when output is ON (Green) PF2 Functions Anti-chattering function, Unit
Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25
Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25
Series C96 cylinders conform to ISO 15552. The series is available with a single or double rod in 6 bore sizes from °32 to °125mm. High accuracy covers and tie rod nuts improve mounting accuracy and extend the cylinder life. Increasing the precision of the bushing and piston rod, as well as reducing tolerances, has decreased the deflection of the piston rod. Standard strokes range from 25
. *2 Linearity 1% F.S. or less Current output Load impedance Maximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 Display 4-digit, 7-segment, 2-color LCD (Red/Green) Sampling cycle: 5 times/s Display accuracy 2% F.S. 1 digit (Ambient temperature of 25C) Indicator light Lights up when switch output is turned ON.
Temperature characteristics 2% F .S. (25C standard) Accuracy Output type Select from NPN or PNP open collector output.
25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.