Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Clean Room, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.07 to 1, Specification: Built-in magnet,
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Plate Cylinder, Additional Function: Standard, Environment, Applications: Non-use of Copper and fluoropolymer-based Material (Partially Plating), Operating Temperature(°C): -, End Locking: No, Valves: No, Operating
How Grip: Pinch, Parallel Type / Open, Parallel Type, Number of Fingers: 2 Pcs., Open Dimension L1(mm): 15.2, Closed Dimension L2(mm): 11.2, Type: [Main Body] Body, Operation Method: Double Acting, Main Body Shape: Square Shape, Gripping Force (Closed Side at 0.5 Mpa)(N): 11, Gripping Force (Open Side at 0.5 Mpa)(N): 17, Environment, Applications: Standard, Additional Function: With Linear
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: None, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches
Bore Size: 10mm, Action: D (Double Acting), Finger Position: Standard, Body Option: Basic, Auto Switch: M9BV--Solid State, Gen. Purpose, 2 Wire, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made-to-Order: X5 (Fluororubber Seal)
This is a legacy product. Please contact us for the latest version.sales@ocaire.com CJP/CJP2 ROUND BODY CYLINDER. 6MM CJP/CJP2 DBL-ACT AUTO-SW. ACTUATOR. 6MM CJP/CJP2 DBL-ACT AUTO-SW. 0.22046 lb. CE.
Available in four bore size options, series CJP2 includes a tiny, but powerful, 4mm bore size option making it the smallest double acting pin cylinder around. 6, 10 and 16mm bore sizes complete the range, all featuring extruded aluminium bodies, making them not only compact, but extremely light?weight.? Series CJP2 is auto switch capable and other options include rubber bumper cushions,
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 20 mm
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 6, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.12 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 5 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 15 mm
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø6 mm, Stroke: 25 mm