(mm) Stroke range A Bore size (mm) AL P B1 B C D FX FD FT GA GB H H1 I J K KA M MM NA S ZZ 20 15.5 to 350 1/8 18 13 50 16.5 8 36 5.5 6 18 12 35 5 31 M4 x 0.7 5 6 3 M8 x 1.25 29 83 121 25 19.5 to 400 1/8 22 17 50 18.5 10 36 5.5 6 18 12 40 6 33 M5 x 0.8 5.5 8 3.5 M10 x 1.25 29 83 126.5 32 19.5 to 450 1/8 22 17 50 20 12 38 6.6 6 18 12 40 6 38 M5 x 0.8 5.5 10 3.5 M10 x 1.25 35.5 85 128.5 40 27
50 0 10 20 30 40 50 Gripping point L Gripping point L mm Gripping point L mm MHS MRHQ16 MRHQ16 MHC Internal gripping 60 60 Pressure 0.2MPa MHT 50 50 Pressure 0.2MPa Overhang H mm Overhang H mm MHY 40 40 0.3MPa 0.3MPa 30 30 0.4MPa 0.4MPa 0.3MPa MHW 0.5MPa 0.5MPa 0.6MPa, 0.7MPa 0.4MPa 20 20 0.6MPa 0.5MPa MRHQ 10 10 Misc. 0 10 20 30 40 50 60 0 10 20 30 40 50 60 Gripping point L mm Gripping point
(Including bracket, screw) Cylinder series Applicable bore size (mm) 40 50 63 80 100 BA3 -040 BA3 -050 BA3 -063 BA3 -080 BA3 -100 CDV3, CDVS, CDL1, CE2, CNA 8-30-61
Mounting Bracket Tie-rod Mounting Style
(Including bracket, screw) Cylinder series Applicable bore size (mm) 40 50 63 80 100 BA3 -040 BA3 -050 BA3 -063 BA3 -080 BA3 -100 CDV3, CDVS, CDL1, CE2, CNA 8-30-61
Mounting Bracket Tie-rod Mounting Style
(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).
20.5 (28.5) A B 15 (22.5) A B 17.5 (25.5) A B 19.5 (27.5) A B 18 (26) A B 16 (24) B 20 27.5 27 24.5 31 25.5 27.5 29 27 24 30 21.5 (29.5) 20.5 (28.5) 15 (22.5) 17.5 (25.5) 19.5 (27.5) 18 (26) 16 (24) 25 30 29.5 27 31 25.5 27.5 29 27 24 30 22.5 (30.5) 21.5 (29.5) 15.5 (23.5) 18.5 (26.5) 20.5 (28.5) 19 (27) 17 (25) 32 33.5 33 30.5 32 26.5 28.5 30 28 25 31 25 (34) 24 (33) 18 (27) 21 (30) 33 (
Bore (mm) -Stroke (mm) 5~50, 75, 100, 125, 150 63-50, 75, 100, 125, 150 1 4~50, 75, 100, 125, 150, Additional symbol B-With limit switch mounting bracket D-With cam K-With special bracket N-Different rod end length Rod attachment No mark-No attachment I-Single knuckle jOint Y-Double knuckle joint 41) Construction/Parts List.
Unit Series AV2000-A AV3000-A AV4000-A AV5000-A Spacer Y200-A Y300-A Y400-A Y600-A Spacer with bracket Y200T-A Y300T-A Y400T-A Y600T-A Applicable model AC20-A AC20-B AC25-A, AC30-A AC25-B, AC30-B AC40-A*1 AC40-B*1 AC50-B, AC55-B AC60-B *1 Except port size 06 Assembly Example eSpacer with bracket qSoft start-up valve Air combination wAC30-03G-A Assembly example Products do not come assembled
D-Y7 W N B D-Y7BA D-Y69 A B D-Y7 WV N B Protrusion [mm] In-line Perpendicular A B D-Y59 O MHW2-20D S 7 12 5 12 12 O MHW2-25D S 7 11 5 10 11 O MHW2-32D S 4 9 2 8 9 O MHW2-40D S 3 8 1 7 8 Hysteresis Switch operating position (ON) O MHW2-50D S 1 6 5 6 Switch return position (OFF) N B D-Y7BA Auto switch model No. Gripper model No.
Load Weight Allowable Moment MY2H/m3 MY2H/M3 MY2H/M1 MY2H/M2 60 50 60 50 60 50 60 50 40 40 30 30 30 30 20 20 20 20 Load weight kg Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 MY2H40 MY2H40 10 10 10 10 MY2H25 MY2H25 MY2H25 MY2H25 5 5 5 5 4 4 4 4 3 3 3 3 MY2H16 2 2 2 2 0.2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 1 100 200 300400 500 1000 1500 100 200 300 400500 1000 1500 100
When P2 + 0.1 b, choked flow P1 + 0.1 293 Q = 600 x C (P1 + 0.1) (1) 273 + t When P2 + 0.1 > b, subsonic flow P1 + 0.1 2 P2 + 0.1 b P1 + 0.1 Q = 600 x C (P1 + 0.1) 1 (2) 1 b 293 273 + t Q : Air flow rate [dm3/min (ANR)], dm3 (Cubic decimeter) of SI unit are also allowed to described by l (liter). 1 dm3 = 1 l .
Table 8-1 Quality criteria for clean water (tap water) Item Unit Criterion Circulating fluid Facility water pH (at 25 oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25 oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Standard Sulfuric acid ion [mg/L] 50 or less 200 or less item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness [mg/L]
B 23.5 A 7.0 B A 10.5 (13.0) B Bore size 50 63 80 23.5 19.5 25.5 12.5 25.5 14.5 25.5 10.5 21.5 14.0 (16.5) 39.5 19.5 39.5 21.5 39.5 17.5 35.5 21.0 (23.5) The values inside ( ) are for the D-A96/A96V.
PA 02 200 VAC 50/60 Hz 01 100 VAC 50/60 Hz 08 48 VAC 50/60 Hz 01 02 03 04 07 08 05 06 002 Applicable valve model No. 13 24 VAC 50/60 Hz VXZ22 VXZ23 03 110 VAC 50/60 Hz 23 440 VAC 50/60 Hz PAX 003 AC 04 220 VAC 50/60 Hz 51 6 VDC Coil combination code 05 24 VDC 53 48 VDC PB 06 12 VDC 55 100 VDC 56 110 VDC (Refer to the table below.) 07 240 VAC 50/60 Hz DC Note) The voltage codes
1 2 L A A-1 1 B (B-2) 6 1 1.5m B (A-2) 5 COM-A/COM B-3 3 3 3m COM-B/ A-3 4 5 5m (3) Shiel d Vcc (B-4) 12 GND (A-4) 13 A (B-5) 7 A (A-5) 6 S B (B-6) 9 B (A-6) 8 3 (14.2) (2 ) 2 1 (8) (1 ) B1 A1 (14) (18) (17.7) 6 5 (3 ) 2 1 B6 A6 15 16 (11) (30.7) 15.2 [820m] (1) (2) -L A B-1 2 A A-1 1 B (B-2) 6 8 8m* B (A-2) 5 COM-A/COM B-3 3 A 10m* COM-B/ A-3 4 B 15m* (3) Shield
Dimensions inch (mm) AK3542 & 4542 M5 x 0.8 Actuation port 1.57 (40) 2.24 (57) 2 x Compression 2 x R, NPT male 2 x Rc, NPT female 0.44 (11.2) B B A A A Connections: N, BRN Connections: 4T, 6T Connections: 4, 6, BR 4 6 4 6 4 6 Ports A B Connections inch (mm) inch (mm) 4T 2.56 (65.0) 1.12 sq. (28.4) 1/4 inch compression 4BR 1.70 (43.2) Rc 1/4 4BRN 2.32 (58.9) 1.12 sq. (28.4) R 1/4 4 1.70
C 5 to 45 Circulating fluid2 Tap water, 15% ethylene glycol aqueous solution, Deionized water Set temperature range1 C 5 to 35 Cooling capacity 50/60 Hz3 kW 8.0/9.0 Heating capacity 50/60 Hz4 kW 1.7/2.2 Temperature stability5 C 0.5 Circulating fluid system Rated flow 50/60 Hz (Outlet)6 L/min 29/45 Maximum flow rate 50/60 Hz L/min 55/68 Maximum pump head m 50 Minimum operating flow rate 50
Reed switch Auto switch A90 Solid state M9B, M9N, F8B, F8N Size: 10, 20, 30, 50 11 Vacuum suction type Clean series 10 Size 20 30 50 11 MSQ B 10 A M9B 22 MSQ B 10 A M9B Number of auto switches A High precision type B Basic type Nil S n 2 pcs. 1 pc. n pcs.