A A 11 20 26 49 300 (lead wire length) 1 P = 19 13.5 L2 5.5 L1 47.5 11 5 n-Rc 1/8, M5 x 0.8 2(A) port 19 35 n-Rc 1/8 3(R) port 47.5 11 R R P = 19 19 L Dimension n: Stations n L 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20 399 388 L1 L2 4-13
The continuous duty AC type is equipped with a rectifier, so a diode will be provided. Construction Symbol (A)2 (R)3 1(P) Component Parts Material Aluminum die-casted No.
ANm0m0-KMmm 5.2-4 40dB(A): High Noise Reduction Silencer Series ANA1 A high noice reduction style silencer keeps the noise level inside a plant below 85dB(A).
Consult with P/A in case of 10mm or less stroke. In general, mounting on a small-size actuator may cause hunting. For prevention, a pilot valve with a built-in output restriction is available. The restriction is removable.
only) 2-4.5 (mounting holes) 67.5 59 19 17 2 R P P R 34 2.3 7 20 Pg.7 4-Rc(PT) 1/8 (ports P, R) A A A P = 19 13.5 L2 L1 4 1 7 8 26 47.5 Approx. 300 (lead wire length) n-Rc(PT) 1/8, M5 x 0.8 (port A) 7 20 34 2-4.5 (bracket mounting holes) 4-M3 x 0.5, depth 6 (bracket mounting screws) 7 8 47.5 15.5 20 25 49 4 L3 7 7 L: Dimension table n: Stations n L 1 35 27 13 2 54 46 32 3 73 65 51 4 92 84
Contact SMC if a stopper cylinder is to be used for stopping a load that is connected directly to a cylinder, as this will cause the cylinder's thrust to act as a horizontal load.
vacuum holding application such as a leak tester, since there is leakage.
L 1 1.5m U 1 1 3 3m V 2 2 W 3 3 5 5m Shield 8 8m Vcc B-1 12 A 10m GND A-1 13 A B-2 7 B 15m A A-2 6 C 20m B B-3 9 B A-3 8 Z B-4 11 Z A-4 10 3 10.5 14.2 2 1 5.6 23.7 A1 2 (7.0) 1 3 3 4 B1 12.7 2 1 18 A4 B4 (6.7) 15 16 11 30.7 44 - 11.2 () L 1 1.5m U 1 1 3 3m V 2 2 W 3 3 5 5m Shield 8 8m Vcc B-1 12 A 10m GND A-1 13 A B-2 7 B 15m A A-2 6 C 20m B B-3 9 B A-3 8
Load DC(-) White OUT2 Installation DC(-) Blue DC(-) 3 CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.
tubing T0604 (A port) (A port) Refer to the above drawing for DIN terminal dimensions.
Auto switches / Proper mounting position for stroke end detection Electrical entry direction: Inward Electrical entry direction: Outward B D C A (mm) D-Z73 D-Y59A,D-Y59B A B C D Bore size D 0.5 4 0.5 3 5 5 C 16.5 23 34 46 46.5 56 6 20.5 27 38 50 50.5 60 -1 2.5 -1 1.5 3.5 3.5 32 15 21.5 32.5 44.5 45 54.5 4.5 8 4.5 7 8.5 9 10 15 20 25 Note 1) The above mentioned values are indicated as a guide
High efficiency nozzle/KNH (mm) Model Nozzle size D Connection thread L1 A Width across flats H1 Connection thread Weight (g) KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R 1/4 R 1/4 R 1/4 14 14 14 52 52 52 46 46 46 38 38 38 D H1 A L1 Reference dimensions after R thread installation. The air blow thrust is improved by 10%.
・When mounting a pressure gauge with a non-standard pressure range on a VEX1 □3□ series regulator, keep in mind that the G36 and the G46 have a max. display pressure of either up to 0.2, up to 0.4, or up to 0.7 MPa.
The part numbers are as follows: G36(46)-2-01, G36(46)-4-01, G36(46)-7-01
Min. 207 Panel 54 72.5 10 69.5 2 R1/8 74 40 7 30 OUT OUT IN 2 x M6 depth 10 2 x Rc1/4 Pressure gauge port Rc1/8 78 70 A 160
A large digital display provides a clear view of the current and set values.
Tightening torque for terminal: 0.6 Nm Series VFS4000/5000 Model Terminal block marking A + A side A side A A side A side B + B VFS 100 VFS 200 VFS4 00 VFS5 00 4 5 4 5 B side B side 3 4 3 4 A side A side B side B side Applicable terminal: 1.25-3.5M, 1.25Y-3L, 1.25Y-3M There is no polarity.
For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level. 3.
Reset (RES) Keeping RY(n 1)A or RY(n 3)A (RES) ON for 50ms or longer RY(n 1)A RY(n 3)A 1 allows an alarm to be deactivated. Some alarms cannot be deactivated by Reset RY(n 1)A or RY(n 3)A (RES). (Refer to section 10.4.1.) If RY(n 1)A or RY(n 3)A (RES) is turned ON with no alarm occurring, the base circuit will not be shut off.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.