SMC Corporation of America
Elite Part Number Search
Search Results "HRS150-AN-40-A"

Set of long clamping screws ZH2-TB203-A 3 M4 x 70 2 pcs. ZH13DA ZH15DA ZH2-TB204-A 4 M4 x 90 2 pcs. ZH2-TB206-A 6 M4 x 130 2 pcs. Hexagon nut (M4) 2 pcs. ZH2-TB208-A 8 M4 x 170 2 pcs. (ZH2-TB201-A)3 1 M4 x 30 2 pcs. Flat washer (for M4) 2 pcs. ZH2-TB302-A 2 M4 x 55 2 pcs. ZH2-TB303-A 3 M4 x 80 2 pcs. ZH18DA ZH20DA ZH2-TB304-A 4 M4 x 100 2 pcs. ZH2-TB306-A 6 M4 x 145 2 pcs.

No.CRBB-OM04 Model name ROTARY ACTUATOR With vertical auto switch unit With angle adjustment unit With vertical auto switch unit and angle adjustment unit Part number / Series CRB10 to 40--A CRB10 to 40--B CRB10 to 40--C INDEX Safety Instructions Front matter 1. Product Description 1 How to Order 1 CRB10 to 40 Rotary actuators / Unit combination illustration 3 2.

Dimensions A B VQD A VQZ1000 VQZ2000 VQZ3000 67 81 93 35 43 52 VZS VFS Individual EXH spacer VVQZ1000-R-5-M5 VVQZ2000-R-5-01 VVQZ3000-R-5-02 VS M5: VQZ1000 Rc(PT)1/8: VQZ2000 Rc(PT)1/4: VQZ3000 VS7 B Used to form a separate exhaust port for an interior manifold station or stations.

The product can be used at an ambient temperature as low as 20C, but take measures to prevent the solidification or freezing of impurities, etc. 2. When using for water, etc. in a cold area, devise a means to prevent freezing, such as draining the water from pipelines after stopping supply and exhaust water for a pump or other device.

Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit.

It is not suitable for the separation of water and oil. 318 Integrated production in a clean environment Integrated production in a clean environment Under a clean environment, all components have undergone ultrasonic cleaning. Assembly, inspection and antistatic double packaging processes are conducted in an integrated production system.

Y7BA is applicable to "-X5" oil proof type (p.2.2-6). 2.2-1 Wide Opening Air Gripper Series MHL2 Specifications 10 16 20 25 32 40 Bore size (mm) One unit can handle workpieces with various diameters Fluid Air Double acting Action A large amount of gripping force is provided through the use of a double piston mechanism, while maintaining a compact design 0.1 to 0.6 0.15 to 0.6 Operating pressure

Note 2) In the case of the body ported type, the pilot type (VZ32R) is used exclusively on a manifold. An external pilot style that can be used individually is available as a made-to-order. For details, refer to the page 4-6-46.

Calculating Acceleration/deceleration conversion example using an actuator with a 8 [mm] lead with an acceleration of 3000[mm/sec2].

Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Caution: Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Warning: Danger : Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury.

Due to meter-in control, the cylinder moves from A to B regardless of whether it is an initial operation or a normal operation. When it reaches B, the head pressure (PH) rises quickly as indicated by the line from C to D.

Refer to p.0-33 for Safety Instructions and p.0-37 to 0-40 for common precautions. External Pilot Vacuum Pilot Caution When using the VNB 1V N.C. vacuum pilot, maintain the specified pilot pressure by providing a tank with an appropriate capacity or by acquiring the pilot pressure from an area near the vacuum pump.

hold Series MHK2 40 40 Pressure 0.6MPa Holding force (N) Holding force (N) Pressure 0.6MPa 30 30 0.5MPa 0.5MPa 20 20 0.4MPa 0.4MPa L L 0.3MPa 10 10 0.3MPa 0 0 10 20 30 40 50 60 10 20 30 40 50 60 Holding point L(mm) Holding point L(mm) Precautions when using the single acting type: If a moment such as that illustrated below is applied to the finger, the finger might not be able to retract

Diaphragm Assembled in a clean room.

Do not Do not use the product in a place where static electricity is a problem. Otherwise failure or malfunction of the system can result. Do not If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system. Check the product for proper operation. Otherwise malfunction can result, causing an accident.

(mm) Model CXS10-10 S SS ZZ Z 10 70 87 30 20 80 97 30 30 90 107 40 40 100 117 40 21-/2210-/11-/12CXS10-20 CXS10-30 CXS10-40 CXS10-50 21-/2210-/11-/1221-/2210-/11-/1221-/2210-/11-/1250 110 127 40 21-/2210-/11-/1283 Dual rod cylinder CXSL 1221CXS / 10-/1122Basic style / CXS15, CXSL15 10-/11221221S ZZ SS 20 10 9 2-4.3 through Z 28 counter bore depth 4.4 18 5 30 1 M6 x 1.0 x 5L (Hexagon socket

Our pressure switches do not have an explosion proof rating. Never use it in the presence of an explosive gas as this may cause a serious explosion. Panel Caution Panel mounting adapter A Panel mounting adapter B 1. Do not use in an environment with spattering liquid of oil or solvent. 2.

L 5 to 6 Straight bladed watchmaker screwdriver Switch mounting screw (M5 X 4l) When auto switch D-Y59 A is used B Auto switch L Note) Use a watchmakers screwdriver with a grip diameter of 5 to 6mm to tighten the auto switch mounting screw.Use a tightening torque of 0.05 to 0.1Nm. As a rough guide, tighten the screw an additional 90 after feeling a tighten resistance.