(except L and T1 kits) Note 3) Available only for F, L and T1 kits. Note 4) IP65 is available only for L, T and S kits. Note) In case of CM indicate on a specification sheet.
(for F, L, S & T1 kits) VVQ5000 3A 1 VVQ5000 2A 1 Electrical entry Electrical entry T1, F, L, T, S kits F kit (connector side) C kit (plug lead type) T1, F, L, T, S kits F kit (connector side) C kit (plug lead type) L F Note1) L F Note1) C C Option Option Nil W Note 2) Standard IP65 enclosure Exhaust cleaner mounting Rc1 Exhaust cleaner mounting Rc1 1/2 Direct exhaust with silencer box Standard
Base mounted Body ported Base mounted Voltage 5 6 24VDC 12VDC Port size Nil M5 01 01F 01N 01T Without sub-plate (PVQ13, 33) With sub-plate (PVQ13 only) Rc 1/8 G 1/8 NPT1/8 NPTF 1/8 Electrical entry Orifice size L type plug connector, with lead wire (PVQ13 only) M type plug connector, with lead wire (PVQ13 only) Grommet (PVQ31, 33) L 03 04 06 08 16 23 40 0.3mm ( for PVQ13) 0.4mm ( for PVQ13
Type L One-touch connection Screw-in connection [L/min(ANR)] 1.
An example of when the SI unit station number is set to 01 is shown below.
A Mounting part (1) Fixed PD port 3 Guideline of PD port 1 PD port 2 tightening torque 3 to 5 [N-m] (5) Recommended One-touch fitting to be mounted at the PD port is the KQ2S06-01[]S or KQ2S07-34[]S. One-touch fitting may interfere with the top surface of the pad depending on the fitting dimensions.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 2 With neon light (110 VAC, Green) Flow range ZSP 3 With neon light (220 VAC, Red) Low flow setting possible (1 l/min) 10 1 to 10 l/min 4 With neon light (220 VAC, Green) 20 10 to 20 l/min Simple flow setting Without removing the cover, you can set
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
min (ANR) Max. suction flow rate l/min (ANR) Model S M H ZMA05H 0.5 12 18 ZMA07H 0.7 24 23 0.5MPa ZMA10H 1.0 46 36 2 stage diffuser ZMA13H 1.3 95 40 ZMA07M 0.7 16 20 ZMA10M 1.0 0.35MPa 26 32 ZMA13M 1.3 70 36 ZMA13S 1.3 75 38 1 stage diffuser 0.45MPa ZMA15S 1.5 90 45 SMC Pneumatics, Inc.
Fluoro rubber Cle6n ieguletd Fluoro rubber & Body size Fluorc resin 'l 10-32 UNF Construclion o-Non relieving (standard) 'l -Relieving {only applicable to Airor N2 gas) NoteiConsull factory ior applications ol othr tluids.
min (ANR) Max. suction flow rate l/min (ANR) Model S M H ZMA05H 0.5 12 18 ZMA07H 0.7 24 23 0.5MPa ZMA10H 1.0 46 36 2 stage diffuser ZMA13H 1.3 95 40 ZMA07M 0.7 16 20 ZMA10M 1.0 0.35MPa 26 32 ZMA13M 1.3 70 36 ZMA13S 1.3 75 38 1 stage diffuser 0.45MPa ZMA15S 1.5 90 45 Series ZMA How to Order ZMA 07 1 H K 5 T14 C Nozzle diameter Switch lead wires (connector type) 0.5mm 0.7mm 1.0mm 1.3mm
Symbol Nil N F Option Option Symbol Applicable actuation Built-in solenoid valve Air Operated PB1013A Air operated Port size Port size 1/8 Nil B N None With foot With silencer Symbol 01 When option is more than one, suffix in alphabetical order.
Clean One-touch fittings (for blowing) 04 06 08 10 12 4 6 8 10 12 Thread connection Tubing (rod) connection 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 K Model H L T Y U R Male connector, Straight union Union elbow, Male elbow Male branch tee, Union tee Male run tee Male branch, Union "Y" Plug-in reducer M Plug Same dia. tubing Different dia. tubing (plug-in reducer) 4 6 8 10 12
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: N (w/o Lead Wire w/Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
P A B C D E G J M N Q R S T U V AMK20 1/81/4 40 133.9 17.5 21 25 21 30 27 22 5.4 8.4 60 2.3 28 AMK30 1/43/8 53 167 21.5 26.5 30 35 26.5 41 35 25 6.5 13 71 2.3 32 AMK40 1/43/81/2 70 212.5 25.5 35.5 38.4 40 35.5 50 52 30 8.5 12.5 88 2.3 39 semi-standard bowl Semi-standard specifications Model Metal bowl No.
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)
H2 L3 L2 L1 All Ports: Screw-in Model H1 H2 H3 L1 L2 L3 L4 Connection thread 1 Connection thread 2 Connection thread 3 ZH05DA-01-01-01 12 12 12 67 42.5 27 26 Rc1/8 Rc1/8 Rc1/8 ZH07DA-01-01-01 70.2 ZH10DA-01-01-01 76.4 ZH13DA-01-02-02 17 17 90.8 51 29.5 36.3 Rc1/4 Rc1/4 ZH15DA-02-03-03 17 19 19 108.2 63.3 34.3 37.1 Rc1/4 Rc3/8 Rc3/8 ZH18DA-03-03-03 19 131.1 73.6 41.1 39.1 Rc3/8 ZH20DA-03-04
Description IR1000 IR3000 IR3020/3120 IR2020/2120 IR3010 IR1020 IR2000 IR2010 IR1010 Bracket Pressure gauge P36203018 P36202028 P36201023 G43-2-01 G43-4-01 G43-10-01 G43-4-01 G43-10-01 G33-4-01 G33-10-01 G43-2-01 G33-2-01 Accuracy 3% (Full span) 14-5-7 7 Series IR1000/2000/3000 Construction IR1000 IR2000 IR3000 q i o !4 q o i !