6 Voltage 1 to 6 L M 2 3 (VQ0) (VQ1000) (VQ2000) L M 2 3 (VQ0) (VQ1000) (VQ2000) VQ110L VQ110L Double (latching) Double (latching) Voltage 1 to 6 Voltage 1 to 6 The direction of the L and M connectors of a pilot valve is opposite to that of the single and double styles.
Nil Without sub-plate* Manual override 02 1/4 03 3/8 04 1/2 42 Grommet/ (L/M) plug connector DIN terminal Nil Non-locking push type * With a gasket and 2 mounting bolts Grommet/ (L/M) plug connector Electrical entry B Locking slotted type Grommet L plug connector M plug connector DIN terminal G: Lead wire length 300 mm L: With lead wire (Length: 300 mm) M: With lead wire (Length: 300 mm)
Intermittent control timer (P.460) 449 IZN10 Series Accessories Bracket L-bracket/IZN10-B1 Pivoting bracket/IZN10-B2 Fixed mounting Pivot mounting Power supply cable DIN rail mounting bracket/IZN10-B3 [Standard length] IZN10-CP (3 m) IZN10-CPZ (10 m) [Non-standard length] IZN10-CP -X13 01 Cable length 1 m 2 m 01 02 Manifold Single unit The L-bracket and the DIN rail mounting bracket
AK ASS ASR Flow Rate and Effective Area ASF Model AS121FM AS131FM AS221FM-01 AS231FM-01 AS221FM-02 AS231FM-02 3.2, 4, 6 6, 8 3.2, 4 8, 10 4 6 Metric size Tubing O.D. 1/8", 5/32", 3/16" 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8", 5/32" 5/32" 3/16" Inch size Air flow (l/min(ANR)) 7 12 38 Controlled flow JIS Symbol 0.1 Effective area (mm2) 0.2 0.6 Flow rate (l/min(ANR)) 230 180 460 260 390
ZS-35-C X X X X X E ZS-35-D X X ZS-35-F X X X X X + F ZS-35-G X X 1/ 1 ZS-24-A A M35 L,M45 L 2 ZS-24-B B M45 L, 2 ZS-24-D D M35 L,M45 L 2 ZS-35-C (01,N01) ZS-35-D (W1,WF1,M5,C4,C6) ZS-35-F +(01,N01) ZS-35-G +(W1,WF1,M5,C4,C6) -10No.PS-OMM0006CN-E M8(3 ) 01 N M L ISE40A 1/ 2 ISE40A -0.11.000 MPa Y ZSE40A 0.0-101.3 kPa K + T + 1 01 R1/8(M5) N01 NPT1/8(M5) A A D D N NPN1
COM COM 0.6 m VVQ5000-44A-8-l () Red (+) () Red (+) 1.5 m VVQ5000-44A-15-l SOL.B SOL.B (+) White () (+) White () 3 m VVQ5000-44A-30-l Positive common Negative common Positive common Negative common l: Number of stations 1 to 16.
for pressure sensor controller (1 pc.) + Sensor cable (3 m) Description Part no.
The graphs above indicate the total stroke time and speed at the end with respect to various load ratios and strokes for each cylinder bore size. 0.5 MPa Inlet pressure Total stroke time (t) SV1000: 1 m, SV2000/3000: 2 m, SV4000: 3 m Piping length Speed d% d% (1) Stroke (mm) Stroke (L) Speed at the end Vertical upward Cylinder direction Stroke Speed controller Meter-out, Directly connected
Output Specification: NPN Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -
Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 1 Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Option 1: w/o Lead Wire, Option 2: Bracket A, Vertical Mounting, Option 3: -
Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: SI Unit Only, Piping Specification: R 1/8, Lead Wire: w/o Lead Wire, Bracket: Bracket A, Vertical Mounting, Operation Manual: -
4 VVQC1000-T0-1 Terminal block box housing assembly T kit VVQC1000-L25-0-1 L kit with 0.6 m lead wire !5 VVQC1000-L25-1-1 Lead wire housing assembly L kit with 1.5 m lead wire VVQC1000-L25-2-1 L kit with 3.0 m lead wire !6 VVQC1000-M26-1 Circular connector housing assembly M kit, 26 pins 586 VQC1000/2000 Series Plug-in Unit Base Mounted Manifold Assembly Part No.
5 M/10 Mbps 9.6 k/19.2 k/45.45 k/93.75 k/ 187.5 k/500 k/1.5 M/3 M/6 M/12 Mbps 21.6 to 26.4 VDC 100 mA or less Communication speed 21.6 to 26.4 VDC 100 mA or less Power supply for control Power supply voltage Internal current consumption 22.8 to 26.4 VDC 11 to 25 VDC 100 mA or less Power supply for output Power supply voltage Power supply for Power supply voltage communication Internal current
Weight (g) M L2 L1 A 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 DL04-01 15 3.5 23 DL04-02 17 19 4 10 10 23.5 19.6 30 DL06-01 9 25 17 10 19.6 23.5 6 DL06-02 16 19 31 14 12 DL06-03 22 53 26.5 24.5 21.6 22.6 24.5 25.8 24.5 29.4 29.6 30.3 29.4 91 DL08-01 18 32 19 8 14 DL08-02 16 21 38 14 12 24.5 DL08-03 22 54 26.5 31 10 17 DL10-02 23 51 14 26.5 DL10-03 17 22 57 DL10-04 27 28.5 100
ATTACHMENTS / ACCESSORIES OPTIONS PART NUMBER Attachments / Accessories (Options) part number Section Model Descriptio For AC10*-A For AC20*-A For AC25*-A For AC30*-A For AC40*-A For AC40*-06-A Note1) Pressure gauge Standard G27-10-01 G36-10-01 G46-10-01 Round type G27-10-01 Note2) G36-4-01 G46-4-01 0.2 MPa setting Round type Standard G36-10-01-L G46-10-01-L Option G36-4-01-L G46-4-01-L