Type: 332 (Body Ported), Valve Option: W (For Low Wattage), Rated Voltage: 5 (24 VDC), Electrical Entry: G (Grommet, Lead Wire 300mm), Light/Surge Voltage Suppressor: S (w/Surge Voltage Suppressor), Port Size: 01 [Rc 1/8, (Base Mounted w/Sub-plate)], Thread: T (NPTF), Bracket: F (w/Bracket, Not Assembled)
VZA4221-01 VZA4321-01 VZA4421-01 VZA4141-1-01 VZA4141-1-02 VZA4141-2-01 VZA4141-2-02 VZA4241-1-01 VZA4241-1-02 VZA4241-2-01 VZA4241-2-02 VZA4341-1-01 VZA4341-1-02 VZA4341-2-01 VZA4341-2-01 VZA4441-1-01 VZA4441-1-02 VZA4441-2-01 VZA4441-2-02 Single Double Closed center Exhaust center 0.44 0.44 0.44 0.44 0.25 0.25 0.25 0.25 1.7 1.7 1.7 1.7 0.49 0.49 0.47 0.47 0.14 0.14 0.15 0.15 2.0 2.0 1.9
): 0.18kg Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil
): 0.18kg Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B) 2 Single Nil
(3-position): 0.18kg Series EVS1-01/1-02 How to Order FG S EVS1 01 3 M0 Valve Thread type Size Nil F T 01 02 Rc Size 01 G Size 02 NPTF Passage symbol Port size (A) 4 (B) 2 Size 02 Size 01 Piping specifications Symbol Nil A01 A02 FG Without sub-plate 1 (P) 5 (R1) 3 (R2) Side-ported 1/8 (A) 4 (B) 2 Side-ported 1/4 FHG Number of solenoids 1 (P) 5 (R1) 3 (R2) Sealing type S D (A) 4 (B)
For vacuum/ compound pressure ZSE30A 01 N M ISA2 Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.
Time t (ms) t (ms) (Averaging) (Averaging) Switch output operation when normal ON [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.
Time t (ms) t (ms) (Averaging) (Averaging) Switch output ON operation [Selectable response times: t] 2.5ms (normal), 24ms, 192ms or 768ms The normal setting is selected when shipped from the factory.
This function prevents such momentary pressure drops from being detected as abnormal pressures by allowing the response time selection to be changed. t (ms) t (ms) Time (Averaging) (Averaging) Switch output operation when normal ON [Selectable response times: t] 2.5 ms (normal), 24 ms, 192 ms or 768 ms The normal setting is selected when shipped from the factory.
A port size Symbol Port size Exhaust style Individual exhaust Common exhaust 01 1 8
Size: 01(Size 26mm), Stations: 12 Stations, A, B Port: 02 (Side, 1/4), Port Thread: T (NPTF), SI Unit: SDZEN (EtherNet/IPâ„¢), End Plate: w/o SI Unit/End Plate, SI Unit COM: N (-COM), Number of Input Blocks: 3 Input Blocks, Type of Input Block: 2 (M12, 4 Inputs), Input Block COM: PNP or w/o SI Unit/Input Block, Silencer: S (Direct Exhaust w/Built-in Silencer)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: L (No Flow Adjustment Valve, Rear Ported), Port Size: C4 (ø4), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: A (Out 1: NPN; Out 2: NPN), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: T (Panel Mount Adapter, w/o Flow Adjustment Valve)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: D (Screwdriver Operated Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: None, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Function: 1 (2 Position Single), Piping: 4 (Base Mounted), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: LN (L Plug Connector w/o Lead Wire), Surge Suppressor: U (Indicator Light w/Surge Suppressor Non-polar), Manual Override: D (Screwdriver Operated Style), Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
Size: 01(Size 26mm), Stations: 8 Stations, A, B Port: 03 (Side, 3/8), Port Thread: T (NPTF), SI Unit: SD6Q (Serial Kit for DeviceNet™), End Plate: 2 (M12 Connector Power Supply, Max. Supply Current 2A), SI Unit COM: N (-COM), Number of Input Blocks: 0 (w/o Input Block), Type of Input Block: w/o Input Block, Input Block COM: PNP or w/o SI Unit/Input Block
(Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)
: 01 (Base Mounted w/Sub-plate 1/8), Thread: T (NPTF)