SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-V-01-S"

3 10 01 BG ARJ 3 10 F BG With One-touch fitting 04 01 Body size Option specifications 0.7MPa setting (standard) 0.2MPa setting With thread sealant Nil 1 S Model Relieving type 10 When set at 0.2MPa, a pressure gauge is not included.

Series 25 19 dB (A) Page 5-10-4 VEX AN101-01 AN110-01 AN120-M5 AN120-M3 BC sintered body type Ideal for the exhaust of a compact valve or pilot air. 16 dB (A) 21 dB (A) 18 dB (A) 13 dB (A) 100 m AN Page 5-10-5 Silencers Exhaust Cleaner 70 m AMC One-touch fitting connection type Can connect with One-touch fitting directly. 25 dB (A) 30 dB (A) It differs depending upon the model.

U C S O H L 1 Series IRV Dimensions IRV1000 IRV2000 53 55 41 30 50 SMC 35 P K U C SMC S O H L P K U C S O H L 40 34 8 x 6.5 15.4 x 5.4 Approx. 106 Approx. 50.6 18 Approx. 79 Atmosphere Atmosphere 45.5 13 SET VAC SET G SET G 30 SET VAC 43 Pad side Vacuum pump side Pad side Vacuum pump side Approx. 43 35 2-Rc 1/8 Connection port 2-Rc 1/8 Vacuum gauge port 2-Rc 1/4 Connection port Approx. 60

Order Made 2 With IN-OUT Flange 1 With Pressure Differential Gauge (GD40-2-01) A pressure differential gauge can be installed in the body to check the life of the filter element. It allows for easier piping and compact size. For easier flange piping.

How to Order G 3 0 01 06 AS 2 F S With seal Speed controller In the case of M5, seal is inapplicable to the product. Conforms to Food Sanitation Laws (Material of the component parts meets the apparatus and container packaging standards.)

How to Order Symbol 2 1 01 06 2 AS 1 F E S K JIS Symbol Hexagonal lock nut Body size 2 3 4 1/8, 1/4 standard 3/8 standard 1/2 standard With seal Applicable tubing O.D.

R R 1. 2. 2 9 - 3-7 1 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 10 - 2 ON OFF ON ON 1 2 1 1 1 2 3 3 0.3~0.5mm 4 5 0.3~0.5mm 11 - M2.54 5 6 5~6mm 0.05~0.1 Nm90 D-Y59/Y69/Y7P/Y7PV D-M9(V) D-Y7W/Y7WV D-M9W(V) D-M9A(V)L MHL2-10D 0.8 0.3 MHL2-16D 0.5 0.4 MHL2-20D 0.5 0.7 ON MHL2-25D 0.5 0.6 OFF MHL2-32D 0.5 0.6 MHL2-40D 0.5 0.9 1. 2. 12 - 3-8

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

Other parameter settings Front protective cover (Model: ZS-26-01) Normal operation mode Item Default setting Item Default setting [F80] Power saving mode OFF [F 3] Digital filter setting [F 4] Auto-preset function [F 5] Auto shift setting [F 6] Fine adjustment of display value 0.00 sec.

CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nil F N T Rc G NPT NPTF VR Body type Body ported Base mounted 2 4 Port size VH Valve option VPA342 VPA344 VPA542 VPA544 VPA742 VPA744 Port size Rc Without sub-plate 1/8 1/4 3/8 1/2 Symbol Nil V Standard Vacuum VPA544 VHS Nil JIS Symbol Option Option 01 02 03 04 VPA342 542 742 Description

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

Model GS40-M5 GS40-01 GS40-02 AV Air/Inert gas Fluid AU 3% F.S.

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: A (AN10-01, 62 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603), Exhaust Check Valve: K (AKH06-00, for 6mm tubing), Exhaust Solenoid Valve: V (V124-5LU-M5)

06 S K Option Body size Nil K None Hexagonal lock nut 2 3 4 5 6 M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard With seal Type 3 Universal Applicable tubing O.D.

06 S K Options Body size _ K None Hexagon lock nut M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 2 3 4 5 6 With sealant Style 3 Universal Applicable tubing O.D.

First find the ratio of the discharge rate for fresh water when viscosity is 15mPa s from the graph to the left. It is determined to be 48%. 2. Next, the viscosity of 15mPa s and the discharge rate of 200l/min in the required specification example are converted to the discharge rate for fresh water.

First find the ratio of the discharge rate for fresh water when viscosity is 15mPa s from the graph to the left. It is determined to be 48%. 2. Next, the viscosity of 15mPa s and the discharge rate of 200l/min in the required specification example are converted to the discharge rate for fresh water.

Regulator Options None Nil 1348112 G36 10 01 G46 10 02 G36 4 01 G46 4 02 G36 P10 N01 G46 P10 N02 G36 P4 N01 G46 P4 N02 1348110A B Regulating pressure range Bracket 0.05 to 0.85MPa 0.05 to 0.30MPa 0 1 ARX20 Nil F ARX21 Nil F Thread type G Pressure gauge Rc NPT G Nil N F ARX20N ARX21N P Port size Panel nut 1/8 1/4 01 02 Option combination numbers Panel nut is also included

ASS AS121FG AS131FG AS221FG-01 AS231FG-01 AS221FG-02 AS231FG-02 ASR ASQ Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 07, 08, 09, 10, 11 05, 06, 07, 08, 09, 10 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 01, 03, 04 05, 06 03, 04 Number of needle rotations Number of needle rotations Number of needle rotations AS321FG AS331FG AS421FG AS431FG