Signal inputs by external switch There are 2 ports for external switch signal inputs. Example Emission of static electricity is suspended when abnormal purge air pressure is detected by pressure switch. Prevents static neutralization trouble due to pressure drop of compressed air.
This is affected by factors such as leakage in piping, consumption by drain valves and pilot valves, and reduction of air volume due to temperature drops.
For standard installation, turn 2 to 3 turns using tool after fastening by hand. Take care not to damage the product by over torque.
The average velocity of the cylinder is what the stroke is divided by the total stroke time.
For this type of circuit it is made to be reset by air pressure.
Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque. When a switch is tightened beyond the range of tightening torque, the mounting screws or switch may be damaged.
Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires. This may not only cause broken lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque. When a switch is tightened beyond the range of tightening torque, the mounting screws or switch may be damaged.
Note) If it is pressurized by the port indicated with the arrow, the shaft rotates in the clockwise direction. Note) If it is pressurized by the port indicated with the arrow, the shaft rotates in the clockwise direction.
Deterioration by atmosphere Do not use in an atmosphere such as salt damage, sulfurous acid gas which makes the metal corroded, or having solvent, etc. which makes seal deteriorated. 3. Deterioration by ozone Do not use it under the direct sunlight on the beach, or by the mercury lamp, or the ozone generator, because the rubber material will be deteriorated by ozone. 4.
with the stroke by the 1 mm interval by using an exclusive body with the specified stroke Intermediate strokes by the 1 mm interval are available by using spacers with standard stroke cylinders.
Fluid Electrode Electromotive force (E) The electromotive force (E) is proportional to the fluid velocity (V) multiplied by the magnetic flux density (B). The volume flow is calculated by converting the measured electromotive force (E). An oval fluid passage is used to improve the magnetic flux density generated by small amounts of current.
Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method.
The fitting should be provided by the user.
Average speed of cylinder is obtained by dividing the full stroke time by the stroke.
Change by operation display panel Change by mode request About mode request The mode request is the ability to change the operation mode by the serial communication.
This maintains the seal created by the seal , in place, thus shutting the outside air from inside the bowl G. If there is no accumulation of condensate in the bowl G, at this time float M will be pulled down by its own weight, causing valve H, which is connected to lever A, to seal valve seat J.
(Locked by double solenoid valve.) SOL. location SI unit output no. (Locked by double solenoid valve.)
Moreover, due to the fact that bumpers are installed at each end of the piston, overall length is increased by 6mm for 32 and 40, 8mm for 50 and 63, and by 10mm for 80 and 100.
Continuous suction and discharge is performed by the reciprocal motion of the diaphragm. 2.
1 manually counterclockwise lowers piston u, which pushes open the seal created by seal !