SS5V 07 Station Manifold, Tie-Rod Base. 0.47000 lb.
Body/Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (Without Pressure Sensor / Digital Pressure Switch for Vacuum), Connector: L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port: 07
: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)], Individual Release Pressure Supply: D [With Individual Release Pressure Supply (PD) Port Type], Vacuum Break Flow Adjustment: J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type)
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 6 (-100 to 100 kPa, SI Unit only, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)
Body/Exhaust Type: F (For Manifold - Individual Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 6 (-100 to 100 kPa, SI Unit only, w/Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch)
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
Manifold Mounting: A (Direct Mount), Centralized Supply (IN) Piping Position: 2 (Top), Regulator Block Stations: M (10 Stations), IN/OUT Fitting Type: 07 [IN/ø6 (Straight) - OUT/ø4 (Straight)], Accessories: A (w/Pressure Gauge/L Side), Options: 1 (0.35 MPa Setting), Unit Representation: Z (Display Unit for Product Name Plate and Pressure Gauge: PSI)
, Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)], Bracket: w/o Option, Individual Release Pressure Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch)]
Model: 3 (10-SY3000), Stations: 07, SUP/EXH Block Assembly: B (Both Sides, 2 to 20 Stations), A, B Port Size: C6 (One-touch Fitting for ø6)
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
.); Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2")
Simply install betwwen valve and cylinder; 2-speed control of cylinders; Applicable cylinder: Bore size ø10 to ø100; Stroke from 50mm+; Operating pressure: 0.3 to 0.7 MPa; Tube size: mm 04, 06, 08, 10, 12; inch 03, 07, 09, 11, 13
Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 2 (0 to -101 kPa, SI unit only, w/out Energy Saving), Connector: H (300mm Lead wire with M12 connector for IO-Link), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, integral fitting valve, Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.), Normally closed (N.C.), Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2") HIGH PURITY CHEMICAL VALVE
.); Applicable tubing size: 03 (ø3), 04 (ø4), 06 (ø6), 08 (ø8), 10 (ø10), 12 (ø12), 03 (1/8"), 05 (3/16"), 07 (1/4"), 11 (3/8"), 13 (1/2")
Simply install betwwen valve and cylinder; 2-speed control of cylinders; Applicable cylinder: Bore size ø10 to ø40; Stroke from 150mm+; Operating pressure: 0.3 to 0.7 MPa; Tube size: mm 04, 06, 08, 10, 12; inch 03, 07, 09, 11, 13
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Model: 1FS, Thread: R (or None), Port Size: M5 (M5 x 0.8), Width Across Flats: 9 mm (or None: Sizes 2/3/4), Applicable Tubing: 07 (ø1/4"), Seal: without Sealant
AS: AS, Size: 1 (M5 Basis), Style 1: 2 (Elbow), Control Type: 1 (Meter-in), Thread: M5, 10-32UNF, R, Port Size: U10/32UNF, Tube Size: 07 (1/4"), Option: None, Lock Nut: J (Round)