Description Material 1 2 3 4 5 6 7 8 9 10 Body PPS Tube assembly Stainless steel Coil assembly i Armature assembly Stainless steel, NBR, FKM, EPDM r y u q o !0 Return spring Stainless steel Flame Iron O-ring NBR, FKM, EPDM Round head combination screw Iron Cassette POM, Stainless steel OUT IN Seal NBR, FKM, EPDM q Do not disassemble.
1 Output RoHS 3-Screen Display High-Precision Digital Pressure Switch IP40 ZSE20(F)/ISE20 Series How to Order Rated pressure range ISE20 0.1 to 1 MPa M For positive pressure ISE20 M5 N For vacuum/ compound pressure ZSE20 N M M5 q w e r t y u q Rated pressure range e Unit specification w Output specification ZSE20 0 to 101 kPa ZSE20F 100 to 100 kPa Symbol Description N NPN open collector 1
Valve element becomes free to incline and it reaches valve seat o. q Description Note Plated No. Material Cast iron Undercover Body Plated Cast iron Aluminum alloy w e Cover Plate r Iron t Stainless steel Valve element A Valve element B Piston Return spring y Stainless steel u Aluminum alloy i Piano wire o Stainless steel Valve seat !0 Stainless steel Rod !
Description ZFB100/101 ZFB200/201 ZFB300/301 ZFB401 q O-ring for clear cover S11.2 S12.5 S16 S18 Selection O-ring is a set with spare element (I-S-A). Warning 1. Do not use it in a line that is kept pressurized because it could cause the body to break. 13-10-5 3 Series ZFB Dimensions Element Replacement 1.
"i."}Jsr-ot "I r Rod Cross Section, Z + 2 X S T R O K E nod Cover Head Cover Spring Extend/Double Clevis Type (D) nc'rzxo I &:i6iFl-{st'irr.el r q @ f l * I trB Al Bod Cross uNrT rNcH (Mrvr) 010 (318") I Osilttr SERIES NCDJ2 Auto Switch Guide Applicable cylinder bore size (mm) 6 1 0 Mounting 1 6 Band mounted type Grommet Reed Switch P 4 7 -.lHlr Solid State Auto Switch D-H7A1, D-H7A2, D.H7B
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Option: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Option: None, Lead Wire Length: 300mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Function: Standard, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 150mm, CE Compliant: CE Compliant
Symbol: 2 Port, N.C., Function: Power-saving Circuit, Voltage: 24VDC, Wetted Part Material: Plate: PEEK; Diaphragm: Kalrez®, Reverse Mounting Prevention Pin: Reverse Mounting Prevention Pin, Lead Wire Length: 150mm, CE Compliant: CE Compliant
Symbol: 07R6 (2 Port, N.C.), Function: Standard, Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)
Symbol: 07R6 (2 Port, N.C.), Function: Y1 (Power-saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)
Symbol: 10R3 (Base Mounted, 2 Port, N.C., Port 1 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 09R3 (N.C., Port 1 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)
Symbol: 09R4 (N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)
Symbol: 09R6 (2 Port, N.C., Port 1 In, Port 3 Out), Function: Standard, Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Lead Wire Length: 150mm, CE Compliant: Q (CE Compliant)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 105R (Base Mounted, 3 Port, Universal), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: P (Reverse Mounting Prevention Pin), Option: None, Lead Wire Length: 300mm, CE Compliant: Q (CE Compliant)
Symbol: 205R (Base Mounted, 3 Port, Universal), Function: Y (Power-saving Circuit), Voltage: 5 (24VDC), Wetted Part Material: C (Plate: PEEK; Diaphragm: Kalrez®), Sub-plate Material/Port Size: P (Reverse Mounting Prevention Pin), Lead Wire Length, Electrical Entry, Light/Surge Suppressor: 300mm, CE Compliant: Q (CE Compliant)