How to Order How to Order R Mounting -XC6 Stroke Bore size CDG1 G5BAL R Mounting -XC6 Bore size CDM2 H7BAL Type Stroke Made to order specification Made to order specification With auto switch (built-in magnet) With auto switch (built-in magnet) Water resistant 2 color indication solid state switch Water resistant 2 color indication solid state switch Water resistant cylinder Water resistant
How to Order How to Order R R Stroke H7BAL -XC6 CDM2 Mounting Bore size Stroke G5BAL -XC6 CDG1 Mounting Type Bore size With auto switch (built-in magnet) Made to order specification With auto switch (built-in magnet) Made to order specification Water resistant 2 color indication solid state switch Water resistant 2 color indication solid state switch Water resistant cylinder Water resistant
-XC6 Piston rod and rod end nut made of stainless steel -XC13 Auto switch rail mounting style Data -XC18 NPT finish piping port -XC22 Fluoro rubber seals Rod Boot Material With Auto Switch Symbol -XC37 Large throttle diameter of connecting port Maximum ambient temperature Rod boot material Double acting: Auto switch can be mounted for double rod.
XC6 Applicable Series CJ1 q Piston rod y Snap ring Model Action Series Description Vol. no.
Action Double acting, Single rod Bore size (mm) 20, 25, 32, 40, 50, 63, 80, 100 Cushion None Auto switch mounting Rail mounting (D-F7BAL) Piston rod/Rod end nut material: Stainless steel (-XC6) Made to order Specifications other than above are the same as standard, basic style.
Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting
SP 0300 trot Btock 1-lXT01&3Clrt t 4-fNXToa}la.t Hotd Down Bolt. l, 1{ {Or't lt .l DtitEl{stot{s A B c D E 4.01. (102) 2.13 (31) 0.$ (2s) o.17 114 0.31 (8) Mlrntars in Parenthoses Optlonal SPA02O0 Interface apeed control w/crossover pilot holes to connect with sub.olate.
(Molex) CNP151241-0600()56125-0128() CNP251240-0500()56125-0128() CNP351241-0300()56125-0128() CNP57349-5300 3.8mm 4 10 4 (B) 89mm , , (1) (2) [mm2] AWG 1 2 1.25/1.5 16 AI1.5-10BK AI-TWIN21.5-10BK 4 206-204 2/2.5 14 AI2.5-10BU 1. Phoenix Contact 2. WAGOJAPAN (c) CNP2 (L11L21)721-2105/026-000(WAGO) 3.
Magnet: D (Built-in), Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 25 (1"), Stroke A: 0300 (3"), +: None, Stroke B: 0300 (3"), Stroke Adjustment: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number: 2 pcs.
Magnet: D (Built-in), Mounting: S (Side Lug), Bore Size: 400 (4"), Stroke A: 0300 (3"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0300 (3"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
Magnet: None, Mounting: L (Foot), Bore Size: 400 (4"), Stroke A: 0300 (3"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0300 (3"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC11 (Dual Op., Sgl. Rod)
OIl-Delay time 200 +/50mS Series CD5 Auto Switches D-A64 D-A59W D-853, A53 Reed Type Internal Circuit ~"e C) t ~R.o Reed sWltch Luminous diode Z"'" diode Zener dtlXle Surge absOtber D-A54, D-A44 D-A67 Reed sw~ch Zener dlode Indicator light I Operation R., ON Black (+) OperaUng (-) "'"!
-color indication) D-Y59A, Y59B, Y7P Sold state D-F59, F5P, J59 D-Y7NW, Y7PW, Y7BW Diagnostic indication (2-color indication) D-F59W, F5PW, J59W Grommet (In-line) D-F5BA, Y7BA Water resistant (2-color indication) D-F5NT With timer D-P5DW Magnetic field resistant (2-color indication) D-A93V, A96V Grommet (Perpendicular) D-A90V Reed Without indicator light D-A67, Z80 Grommet (In-line) D-A53
Tie-rod Cylinder tube 380
Auto Switch Mounting CH2E/CH2F/CH2H Series How to Mount and Move the Auto Switch
Features Electrical entry D-M9NV, M9PV, M9BV D-M9NWV, M9PWV, M9BWV D-M9NAV, M9PAV, M9BAV D-F59, F5P, J59 D-F59W, F5PW, J59W D-F5BA D-F5NT, G5NT D-A93V, A96V D-A90V D-A53, A56, B53 D-A67 Grommet (perpendicular) Diagnostic indication (2-color indicator) Water resistant (2-color indicator) Solid state Diagnostic indication (2-color indicator) Water resistant (2-color indicator) With timer
PLC Y69A Y7PV Y69B Y7NWV Y7PWV Y7BWV 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A53
IC circuit IC circuit Relay, PLC 3-wire Reed switch Solid state switch Yes Grommet 24 V 2-wire No 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 5 V, 12 V IC circuit BMP1-032 12 V Relay, PLC 24 V Grommet Yes Diagnostic indication (2-color indication) 5 V, 12 V IC circuit 12 V 2-wire Water resistant (2-color indication) Lead wire length symbols: 0.5 m Nil (Example) A53
Nil (Example) A53 3 m . L (Example) A53L 5m . Z (Example) A53Z Note Solid state auto switches marked "" are produced upon receipt of order.
Nil (Example) A53 3m . L (Example) A53L 5m . Z (Example) A53Z 103 Tie-rod Type Low Pressure Hydraulic Cylinder Double Acting/Double Rod Series CHAW Models Light Principle parts are light weight aluminum alloy.
D-A6 o D-A73 & D-A53 0or 24VDC) have a lighr emitting diode as an indicator light, and thsrefore, have poladty. lf using 24VDC, the black lead Wire is (-) side, and the red lead is (+) side. lf connection is revrsed, the light will not go on ahhough the switch wi operate.