SMC Corporation of America
Elite Part Number Search
Search Results "PSE564-A2"

Magnet: D (Built-in Magnet), Series: A2 (Standard), Mounting: F (Rod Flange), Tube Material: Aluminum Tube, Bore Size: 100mm, Port Thread: Rc, Stroke A: 125mm, Rod Boot A: None, Cushion A: Air Cushion, Stroke Adjustment: None, +: None, Stroke B: None, Rod Boot B: None, Cushion B: Air Cushion, Pivot Bracket: w/o Bracket, Rod End Bracket: w/o Bracket, Auto Switch: A93--Reed, DC Volt, AC Volt

Magnet: D (Built-in), Series: A2 (Standard), Mounting: T (Center Trunnion), Tube Material: Aluminum, Bore Size: 80mm, Port Thread: Rc, Stroke: 100mm, Rod Boot: None, Cushion: Air Cushion, Pivot Bracket: None, Rod End Bracket: None, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Series: A2 (Standard), Mounting: C (Single Clevis), Tube Material: Aluminum, Bore Size: 80mm, Port Thread: Rc, Stroke: 250mm, Rod Boot: None, Cushion: Air Cushion

Magnet: None, Series: A2 (Standard), Mounting: T (Center Trunnion), Tube Material: Aluminum, Bore Size: 100mm, Port Thread: Rc, Stroke: 1000mm, Rod Boot: None, Cushion: Air Cushion

Magnet: D (Built-in), Series: A2 (Standard), Mounting: D (Double Clevis), Tube Material: Aluminum, Bore Size: 40mm, Port Thread: Rc, Stroke: 350mm, Rod Boot: J (Nylon Tarpaulin), Cushion: N (Rubber Bumper)

Applicable bore size (mm) A1 A2 E1 L1 MM NDH10 NX RR1 U1 Low Speed I-12A 125 8 54 46 100 M30 x 1.5 25 +0.084 0 32 0.1 0.3 27 33 IY-12 125 25 0.065 0.117 79.5 69.5 5 4 4 x 40 I-14A 140 8 54 48 105 M30 x 1.5 28 +0.084 0 36 0.1 0.3 30 39 IY-14 140 28 0.065 0.117 86.5 76.5 5 4 4 x 40 MQ I-16A 160 8 60 55 110 M36 x 1.5 32 +0.1 0 40 0.1 0.3 34 39 IY-16 160 32 0.080 0.142 94.5 84.5 5 4 4 x 40 *

B1 A2 Blue 0 V IN B2 A3 Green F . G. Ground terminal with 100 or less to use it as a reference electric potential of offset voltage. B1 B5 B3 Yellowish green Ionizer stop signal IN Signal input to turn ON/OFF the ventilation with fan and ion generation. NPN type: To stop fan and ion generation, connect to 0 V.

A2 0 V Blue IN B2 Make sure to ground with a ground resistance of 100 or less to use it as a reference electric potential for ionizer. If not grounded, performance cannot be acquired, and also causes failure of the equipment. A3 F.G. Green AWG20 Signal input to turn ON/OFF the ion discharge. NPN specification: Stops ion discharge by connecting to 0 V.

Number of needle rotations Dimensions D3 Applicable tubing O.D. d D1 L3 A L4 M T H (Width across flats) L2 L1 Metric Size/Inch Size [mm] Model d T H D1 D3 L1 L2 L3 L41 A2 M Weight [g] Unlocked Locked Unlocked Locked AS121F-M3-02A-X790 2 11.9 5 AS121F-M3-23A-X790 3.2 7.2 17.2 21.7 5.8 15.8 20.3 16.9 13.3 AS121F-M3-04A-X790 4 8.2 AS121F-M3-06A-X790 6 10.4 18.6 23.1 16.5 6 AS121F-M3-01A-X790

Magnet: None, Series: A2 (Standard), Mounting: B (Basic), Tube Material: Aluminum, Bore Size: 80mm, Port Thread: TN (NPT), Stroke: 25mm, Rod Boot: None, Cushion: N (Rubber Bumper)

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting), Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Magnet: None, Series: A2 (Standard), Mounting: T (Center Trunnion), Tube Material: Aluminum, Bore Size: 50mm, Port Thread: Rc, Stroke: 175mm, Rod Boot: None, Cushion: Air Cushion

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)

Magnet: None, Series: A2 (Standard), Mounting: G (Head Flange), Tube Material: Aluminum, Bore Size: 80mm, Port Thread: TN (NPT), Stroke: 25mm, Rod Boot: None, Cushion: N (Rubber Bumper)

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: Top Mounting, Motor Type: S2 (AC Servo Motor, Incremental Encoder, Output 100W), Lead: A (LEY25 12mm; LEY32 16mm; LEY32 Top Mount 20mm), Stroke: 150mm, Motor Option: w/o Option, Guide Option: w/o Guide, Cable Type: S (Standard Cable), Cable Length: 5 (5m), Driver Type: A2 (LECSA2-S, 200~230V Incremental, Pulse Input

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: A2 (URJ 1/4), Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]

Sensor Range: 0 [For Positive Pressure (0~1MPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type]

Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: A2 (URJ 1/4), Output Specification: Voltage Output (1~5V) Type, Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]