override Rated voltage Nil Push type 1 2 3 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz B Locking type (Slotted) C Locking type (Manual) 110 to 120 VAC, 50/60 Hz 4 Surge voltage suppressor Option 220 VAC, 50/60 Hz Indicator light 24 VDC 12 VDC 5 6 Light/Surge voltage suppressor E EZ Nil None 7 240 VAC, 50/60 Hz With light/surge voltage suppressor (Type E, T, D, or Y only) 9 Other Z Option S With
13UM: ZP3-16UM: ZP3-10B: ZP3-13B: ZP3-16B: ZP3B-T2BK20-B5 P.50 ZP3B-T2BJ10-B5 P.50 Lateral With Adapter: Vacuum Inlet ZP3-10UM: ZP3-13UM: ZP3-16UM: ZP3-10B: ZP3-13B: ZP3-16B: ZP3B-T2BK3-B5 P.50 Lateral P.51 ZP3-015U: ZP3-02U: ZP3-035U: ZP3B-Y1J3-B3 With Buffer: Vacuum Inlet Construction Adapter Applicable Pad List ZP3-10UM: ZP3-13UM: ZP3-16UM: ZP3-10B: ZP3-13B: ZP3-16B: ZP3B-T2BK6-B5 P.50
Vertical Horizontal l: Load eccentricity m Mounting position m L L to 100 to 300 Maximum speed mm/s to 500 to 100 to 300 to 500 Load eccentricity lmm 100 50 200 100 50 200 100 50 200 1 2 3 4 5 6 7 8 9 10 11 12 Selection graph L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction .
Condition: Pressure 0.5MPa, Load 50%, Piping length 5m Effective area mm 2(Cv ) Cylinder speed (mm/s) 50 63 80 100 125 140 Bore size (mm) 160 180 200 250 300 Port size Rc(PT) 40 250 25(1.4) VEX312 -01, 02 500 750 02 ( 1 4) 60(3.3) 250 500 750 250 500 750 500 750 1000 500 750 1000 250 500 750 250 500 750 VEX332 -02, 03, 04 Body ported Base mounted 03 (3 8) 160(8.9) VEX350 -04, 06, 10 06 (3
Single-phase 200 VAC (50 Hz) Single-phase 200/220 VAC (60 Hz) 20 Options and Available Combinations (Size/Option) A C G K L R T V Symbol Note 2) Nil With heavy duty auto drain (Applicable to medium air pressure) With terminal block for run & alarm signal Timer type solenoid valve with auto drain (Applicable to medium air pressure) With Chinese labels and a Chinese operation manual Option
N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21 AC31 AC41 * Without relief valve option ** With relief valve option mm AC-A A* 90 117 154 AA** 140 181 238 B 160 220 239 C 73 86 92 E 30 38 F 45.5 58.5 75.5 G 40 55 80 J 26 29.5 37.5 K 5 3.5 1.5 M 30 41 50 N 51 64 81 Q 24 35 40 U 5 7 7 V 33 45 50 W 34.5 41 AC21A AC31A AC41A * Without relief valve option ** With relief valve option
CJ216 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 16 Air cushion is not available for 21-/22-.
CN1IF(CONT) 18 - (LEC)(LEC) 5.4 CN2PC/TB (LEC)(LEC-T1-3*G*)(LEC-W2) CN2SWOFF(LEC)(LEC) (LEC-T1-3*G*)(LEC-W2) (1) CN2 (3m) (2) (USB) 120.3 120.3 mm mm 200 200 mm/s mm/s USB (A-miniB type) 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 CN2 () 9.
(Humidity) 2~40 (Relative humidity of 85% or less) Applicable compressor (as a guide) 11 2.2 3.7 5.5 7.5 5.5 3.7 2.2 1.5 0.75 (for screw style) (kW) Single phase, AC100/100 to 110 Single phase, AC100/100 to 110 Single phase, AC200/200 to 220 Power source (V) 50/60Hz 165 195 310 360 330 370 165 195 175 210 210 250 200 230 320 385 335 380 210 240 200 230 170 200 175 210 165 195 165 195 165
Pitch (Section F-F') Port size (The above diagram is for ZFA200) ZFA100 Port size Symbol Model A B 19 18 24 28 1 8 1 4 ZFA200 L1 1 Number of manifold stations Model Symbol 2 56 68 76 88 3 74 86 104 116 4 92 104 132 144 5 110 122 160 172 6 128 140 188 200 7 148 158 216 228 8 164 176 244 256 9 182 194 272 284 10 200 212 300 312 38 50 48 60 ZFA100 L2 L1 L2 ZFA200 13-10-3
+ 45 (n 2) (n = 2, 3, 4, 5) 10 15 50 D(n = 2, 4, 6) Note 3) 15 + 50 (n 2) 2 65 + 50 (n 2) (n = 2, 3, 4, 5) 10 15 65 15 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) 10 15 75 (n = 2, 4, 6) Note 3) (n = 2, 4, 6) Note 3) 20 + 50 (n 2) 2 75 + 55 (n 2) (n = 2, 3, 4, 5) D-B59W 15 20 Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation
Checks and Inspection Table 2 Facility water system Circulating type Transient type Item Circulating fluid Filling of circulating fluid Transient fluid pH [25C] 6.5 to 8.2 6.0 to 8.0 6.8 to8.0 Electrical conductivity (mS/m) [25C] 80 or less 30 or less 40 or less Standard items Chloride ions (mg/L) 200 or less 50 or less 50 or less Sulfuric acid ions (mg/L) 200 or less 50 or less 50 or less
50 50 (mg/L) 200 50 50 [pH4.8](mgCaCO3/L) 100 50 50 (mgCaCO3/L) 200 70 70 (mgCaCO3/L) 150 50 50 (mgSiO2/L) 50 30 30 (mg/L) 1.0 0.3 1.0 (mg/L) 0.3 0.1 1.0 (mg/L) (mg/L) 1.0 0.1 1.0 (mg/L) 0.3 0.3 0.3 (mg/L) 4.0 4.0 4.0 6.07.0 1 2 JIS K 0101 2 a b c 4.2 IDF100150F-W 4 2 IDX-OM-Z004 4 (3) 1 Y Y , Y Y (4) 3 2 (5) 1( 2 3 4 a) 1. 1.5 2. 4.2 IDF100150F-W
VCHC ASR ASQ ASD230F ASD330F ASD430F 100 200 400 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 07,08,09,10,11 300 06 200 50 100 100 0 5 10 0 5 10 0 5 10 Number of needle rotations Number of needle rotations Number of needle rotations ASD530F ASD630F 1500 1000 Flow rate (L/min (ANR)) Flow rate (L/min (ANR)) 12 10,11 10,11,12 08,09 1000 500 06,07 500 0 5 10 0 5 10
Standard stroke 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes are available in 1 mm increments without stroke adjustment with a spacer.
100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500 700 900 10 500 700 900 10 700 1,000 Flow rate Q l/min (ANR) How to read the graph The sonic range pressure to generate a flow rate of 500 l/min (ANR) is P1 0.14 MPa for a 6 orifice (VX2 4), and P1 0.3 MPa for a 4.5 orifice (VX23). 3 2 For Saturated Steam [663
100 60 60 Air consumption Air consumption 150 50 50 75 40 40 100 50 30 30 20 20 50 25 10 10 0 0 0 0.1 0.2 0.3 0.4 0.5 0.6 1.0 2.0 3.0 4.0 5.0 6.0 Supply pressure [MPa] Supply pressure [MPa] Flow rate Characteristics Flow rate characteristics Supply pressure: 0.4MPa Supply pressure: 0.4MPa 100 90 100 90 Vacuum pressure [kPa] Vacuum pressure [kPa] 80 80 70 70 60 60 50 50 40 40 30 30 20 20
o32,a4ol51o IOC) o50 to 61 00/1 0 to 1 0O Singleacting Spring return/extend s 1 2 1 0 6 4 U 5 , 1 0 o50h0.20 Ion.rotating rod Double acting Singl rod o12, @16/5 lD 30 o20, @295to 50 o32, o4ol510 1OO o50, 0631 0 to 1 00 Double rod s12, s1615 lo 30 o20 lo o40l5 to 50 o50, a6310lo 50 @Actuation Doude acting Srngle acting spnng refurn Single acting sprinq extend Larg bore siro Double acting
Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.
121 90 188 141 294 215 482 362 754 565 0.5 25 19 57 42 101 75 157 118 245 179 402 302 628 471 8 5, 10, 15, 20, 25, 30 OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN 50 37 113 84 201 150 314 235 490 358 804 603 1,256 942 8 12, 16 25, 50, 75, 100 25, 50, 75, 100, 125, 150, 175, 200 12 20, 25, 32, 40 16 Strokes other than the above are produced upon receipt of order. 20 Stud Bolt Part Numbers