/VQZ 95 95 95 95 ,N.O. ,N.O. ,N.O. ,N.O. 3 5 3 4(A)5 4(A)2B 1 1 1 1 1 1 1 1 2 2 2 2 0 0 0 0 2 2 2 2 0 0 0 0 3 3 3 3 1 1 1 1 3 3 3 3 1 1 1 1 5 2 3 () () () (3 ) 5 3 NL R LED R 2(B),CM 10 No.VQZ100V-OMT0001 VQZ Series/ / / / DIN DIN DIN DIN DIN DIN 0.30.4Nm VQZ100 VQZ100 VQZ100 VQZ100 300 300 300 300 VQZ200 VQZ200 VQZ200 VQZ200 VQZ1000/2000 VQZ1000/2000 VQZ1000/2000 VQZ1000/2000
Setting range: Auto/100 Mbps/10 Mbps -24No.EX-OMV0017-B (C) System setting System setting display. -25No.EX-OMV0017-B System setting items Description Explanation Define the I/O assignment of the entire wireless system including the wireless slave unit registered to the wireless master unit.
Setting range: Auto/100 Mbps/10 Mbps -24No.EX-OMV0017 (C) System setting System setting display. -25No.EX-OMV0017 System setting items Description Explanation Define the I/O assignment of the entire wireless system including the wireless slave unit registered to the wireless master unit.
Setting range: Auto/100 Mbps/10 Mbps -24No.EX-OMV0017-A (C) System setting System setting display. -25No.EX-OMV0017-A System setting items Description Explanation Define the I/O assignment of the entire wireless system including the wireless slave unit registered to the wireless master unit.
/301 Pulse output (Specifications: Maximum load current of 10 mA; Maximum applied voltage of 30 V) Output Voltage output Note 5) 1 to 5 V Analog Linearity: 2% F.S. or less, allowable load resistance: 100 k or more specifications output Current output Note 6) 4 to 20 mA Linearity: 2% F.S.or less, allowable load resistance: 300 or less with 12 VDC, 600 or less with 24 VDC Power supply voltage
Ratio of resistance [k m] 100 10 50 Particle ratio [number/cc] 1 0 5 10 15 20 25 30 Duration of flow [min] 2 or 3 particles/cc Tube 00 10 20 30 40 50 60 70 Duration of flow [min] The data was obtained by performing an actual 10 minutes supersonic cleaning using an average 16Mcm of deionized water at class 10 clean room (1l/min flow rate).
DC(+) 5 OUT1 4 OUT2 3 FUNC 2 DC(-) 1 -19No.PS-OMU0002CN-D Z/ISE20A(F)-S/-R () DC(+) NPN 2 Max.28 V80 mA 1 V R15 V OUT1 1 k OUT2 S420 mA DC(-) 12 V 300 24 V 600 50 DC(+) -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) DC(+) -X () -S/-R () OUT1 NPN 2 OUT2 Max.28 V80 mA 1 V DC(-) -20No.PS-OMU0002CN-D -V/-T () DC(+) PNP 2 Max.80 mA 1 V T15 V OUT1 1 k OUT2 V420 mA DC(
12 V 300 24 V 600 DC(-) 50 DC(+) -V/-T () OUT1 PNP 2 OUT2 Max.80 mA 1 V DC(-) DC(+) -Y () -V/-T () OUT1 PNP 2 OUT2 Max.28 V80 mA 1 V DC(-) -23No.PS-OMU0008CN-D [] 3 0.2 [] / / OUT1 OUT1 OUT2 OUT2 [F10]30 () 1 3 1 3 5 (63 ) (3 ) () () (26 ) (28 ) (30 ) 3 () 3 -24No.PS-OMU0008CN-D ON OFF ON P_1 H_1 ON OFF [] ISE20C [P_1] OUT1 0.500 MPa [P_2] OUT2 0.500 MPa [
length 300 mm) MN: Without lead wire L: With lead wire (length 300 mm) G: Lead wire length 300 mm + + + + W: With connector cable Note 1) LN: Without lead wire LO: Without connector MO: Without connector H: Lead wire length 600 mm + + Note) When placing an order for body ported solenoid valve as a single unit, mounting bolt for manifold and gasket are not attached.
(With gasket and screws) Body option Electrical entry M: Main/Pilot valve common exhaust type 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Manual override Grommet L plug connector M plug connector M8 connector M: With lead wire (Length 300 mm) L: With lead wire (Length 300 mm) G: Lead wire length 300 mm MN: Without lead wire WO: Without connector cable Nil: Non-locking push
Electrical entry 24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Grommet L plug connector M plug connector M8 connector E: Push-turn locking lever type G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire WO: Without connector cable CE-compliant +Nil Q +CE-compliant Note) CE-compliant: For DC only. + + H: Lead
For sub-plate type, manifold type 41, S41, 42, S42, 42R, S42R (With gasket and screws) Body option Nil: Individual pilot exhaust type Electrical entry Manual override 24, 12, 6, 5, 3 VDC/100, 110, 200, 220 VAC 24, 12, 6, 5, 3 VDC Nil: Non-locking push type Grommet L plug connector M plug connector M8 connector R port P, E port G: Lead wire length 300 mm L: With lead wire (Length 300 mm) M
or less 180 or less 0.8 1.4 100 90 20 14 13.2 Response time (1) (ms) VFN Max. operating frequency (c.p.m.) (2) DC AC DC AC 1.6 2.4 300 360 50 60 24 Weight (kg) 50 Hz Apparent power (VA) Inrush 60 Hz AC 50 Hz Holding 60 Hz Power consumption (W) DC Note 1) Based on JIS B 8375-1981.
Cycle Rate 300 cPM Weight (Valve Body Only) oz. (o) 5.1 (144.6) 10.3 (292) Materials Patented Spool and Sleeve Design High Flow vs.
For Air Upstream pressure of valve P1 1.0 MPa 1.0 Downstream pressure of valve (P2) MPa Downstream pressure of valve (P2) MPa 0.8 Subsonic Critical pressure 0.9 0.6 0.7 0.8 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 VX211 VX22 VX23 VX2 4 VX2 5 VX2 60-02 VX2 602 50 100 150 200 250 300 350 3 100 200 300 400 500 600 4.5 200 400 600 800 1,000 1,200 3 2 3 2 3 2 3 2 03 04 6 500 1,000 1,250 8 500
m 3/h) (120 m 3/h) 11 SCFM 16 SCFM 26 SCFM 43 SCFM 62 SCFM 80 SCFM 45 F (7.2C) (19 m 3/h) (27 m 3/h) (45 m 3/h) (74 m 3/h) (106 m 3/h) (136 m 3/h) 17 SCFM 28 SCFM 45 SCFM 65 SCFM 86 SCFM 12 SCFM 50 F (10C) (20 m 3/h) (28 m 3/h) (47 m 3/h) (77 m 3/h) (110 m 3/h) (147 m 3/h) 100psig (0.7MPa) 100 F (37.8C) 100 F (37.8C) 115V 60Hz 41-122 F (5-50C) 22psig (0.15MPa) 150psig (1.0MPa)
Cycle Rate 300 cPM Weight (Valve Body Only) oz. (o) 5.1 (144.6) 10.3 (292) Materials Patented Spool and Sleeve Design High Flow vs.
Options J: With drain guide T: With element service indicator Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35 O 54 66 66 80 80 88 88 102 136 P 70 84 84 100 100 110
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur. 2.
Example: Set 20 W (100 W 20%) for the 100-W external Regenerative resistor with natural convection cooling method: Pn600 = 2 (unit: 10 W) Note 1. If Pn600 is not set to the optimum value, alarm A.320 will occur . 2.