SMC Corporation of America
Elite Part Number Search
Search Results "RZQB40-75-50"

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

Max. operating pressure Note 1) 2R (MPa) One-touch fittings, Insert fittings, Self-align fittings, Miniature fittings Applicable fittings Note 1) Note 2) Min. bending radius 100 15 25 30 50 65 13 20 24 30 40 50 60 Min. bending radius (mm) Note 3) Fixed end Bending value (Reference) 75 12 20 23 40 48 10 15 18 23 30 40 45 40 to +100C, Water: 0 to +70C (No freezing) Nylon 12 Operating temperature

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~50, End Locking: No, Valves: Presence, Operating Pressure(MPa): 0.15~0.9, Cushion: With cushions on both sides, Specification

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

75 kPa to 0.25 MPa [0 to 0.6 MPa]1.6 mm [1 mm]15 ms or less (at pneumatic pressure)Zero leakage, either external or internal (at water pressure)0.38 MPa [0.9 MPa]0 to 50 C0 to 50 C (with no condensation)50 lFreeIP40 or equivalent45 g12, 24 VDC?10% of rated voltageClass B5.5 W(0.23 A)1 W60 dB

consumption ZQ1053M-K1Y5L-D31C ZQ1103M-K1Y5L-D31C 10 -20 -20 Maximum suction flow 5 0 10 15 0.1 0 0.2 0.3 0.4 0.5 0.6 Suction flow (l/min(ANR)) Supply pressure (MPa) ZQ110 Exhaust Characteristics ZQ110 Flow Characteristics Maximum suction flow (l/min(ANR)) Air consumption (l/min(ANR)) Maximum vacuum pressure (kPa) Maximum vacuum pressure (kPa) Maximum vacuum pressure -80 -80 60 -60 -60 50

Low friction, double acting, single rod, Bore size *: 20, 25, 32, 40, 50, 63, 80, 100, Standard stroke *: 25, 50, 75, 100, 125, 200, 250, 300, Auto switch capable, Variety of lead wires and prewired connectors ROUND BODY CYLINDER. CG1-Z Cylinder, FRANCE SPL. 5.20000 lb. 333.