This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, 3-POSITION, ACTUATOR, RZQ 3-POSITION CYLINDER, LC, 32MM RZQ OTHERS (COMBO), 2.95786 lb
1000 40 32 10 100 100 1000 Speed (mm/s) Series CH2G/H Load weight for horizontal motion Speed chart (C rod retraction, pressure 14MPa) 10 100 10 Load weight (kg) 80 63 50 m 1000 40 10 100 100 1000 Speed (mm/s) Series CH2G/H Load weight for horizontal motion Speed chart (extension, pressure 14MPa) 10 100 10 Load weight (kg) 80 63 m 50 1000 40 32 10 100 100 1000 Speed (mm/s) 31 Series CH2E
M18 x 1.5 M22 x 1.5 A18 A22 M18 x 1.5 (40 to 80) M22 x 1.5 (100, 125) 40 50 40 50 Torque Related 63 63 Equipment Vacuum entry 80 80 100 100 B01 N01 T01 1 8 NPT 1 8 NPTF 1 8 Rc 125 125 Pad type H Heavy duty Buffer stroke (Rotating) Stroke 40 50 63 80 100 125 50 25 Material N S NBR 75 Silicon rubber Urethane rubber Fluororubber 100 U F E EPR 1193 Series ZPT ZPT HJ-01-A18 (With buffer) 40 50
60 65 70 75 80 85 90 95 100 105 65 70 75 80 85 90 95 100 105 140 165 75 80 85 90 95 100 105 110 115 150 175 80 85 90 95 100 105 110 115 120 155 180 90 95 100 105 110 115 120 125 130 165 190 100 105 110 115 120 125 130 135 140 175 200 115 120 125 130 135 140 145 150 155 190 215 CLQB20-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CLQB25-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D CLQB32
100 75 28 65 32 13 22 20 M12 x 1.75 26 26 29 M22 x 1.5 35 1/2 26 12 130 75 155 90 100 38 6.5 118 118 90 35.5 80 35 13 27 19 M12 x 1.75 27 26 34 M27 x 2 35 1/2 34 16 145 90 172 100 125 38 6.5 140 140 112 35.5 80 35 15 27 19 M14 x 2 27 30 34 M27 x 2 35 1/2 34 18 170 112 200 100 160 42 9 174 174 140 45 100 38 17 36 22 M16 x 2 28 34 38 M33 x 2 40 3/4 43 20 205 140 240 108 (mm) Bore size (mm)
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
28 10, 20, 30, 40, 50, 75, 100 Note) Available only for MQQL.
Standard Strokes Standard strokes (mm) Bore size (mm) 20 32 40 50 63 80 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Double acting/Double rod 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25,
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Standard type Nil PNote 1) Axial piping type Note 1) The combination of axial piping type and both ends adjusters or retraction end adjusteris not
OVERALL ACCURACY < +/3% FS BFSL including linearity, repeatability and hysteresis DIMENSIONS 2.875" x 2.125" x 3.5" (73 x 54 x 89 mm) WEIGHT 8 oz (227 g) DRIVE UNIT MOTOR TYPE 15 bi-polar stepping COIL RESISTANCE 36 Ohms/Phase RECOMMENDED CURRENT < 170 mA / coil for 100% duty cycle GEAR RATIO 20.83:1 TYPICAL STEP RATE 200 steps / sec SDR-800/SDR-900 SERIES REGULATORS REGULATOR TYPE Constant
Possible to use in vacuum to 100 kPa Tubing material Tubing O.D.
(mm ) . 100 125 150 I 50 75 100 125 150 75 ~ 50 I 75 50 100 125 150 107 40 70 B3 83 97 11 5 128 128 194 52 62 204 212 225 225 1 83 107 50 70 83 ! 97 115 128 I 128 52 62 204 19' 212 2.?
Extension end 8 10, 20, 30, 40, 50, 75 Rubber stopper Retraction end Both ends 12 10, 20, 30, 40, 50, 75, 100 16 10, 20, 30, 40, 50, 75, 100, 125 20 10, 20, 30, 40, 50, 75, 100, 125, 150 25 10, 20, 30, 40, 50, 75, 100, 125, 150 Functional option Nil Standard P Note 1) Axial piping Note 1) The combination of axial piping and both ends adjusters or retraction end adjusters is not available.
0 25 50 75 1.0 0 2 6 4 8 1.0 100 0 25 50 75 10 Input signal (%F.S.)
The guideline is 80% or less. 0 to 100 % 7 Effective load ratio The continuous effective load torque is displayed. The effective value is displayed relative to the rated torque of 100%. 0 to 300 % 8 Peak load ratio The maximum torque is displayed.
kPa (Detection distance 0.01 to 0.25 mm) 50 to 200 kPa (Detection distance 0.03 to 0.50 mm) Set pressure range 0 to 98 kPa 0 to 0.98 MPa 0 to 101 kPa 100 to 100 kPa 10 to 101.3 kPa 0.1 to 1 MPa 0 to 100 kPa 0 to 1 MPa 0 to 101 kPa 0.1 to 0.45 MPa 0.1 to 0.4 MPa 20 to 101 kPa 101 to 101 kPa 0.1 to 1 MPa 0.4 to 10 MPa 0.5 to 15 MPa 100 to 100 kPa 0.1 to 1 MPa 0 to 1 MPa Voltage 12 to 24 VDC
200 200 0.1 MPa 100 100 0 1 2 3 4 5 6 7 8 9 11 10 0 0.1 0.2 0.3 0.4 0.5 Number of needle rotations Fluid pressure (MPa)
0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-04 {Rc1/2} FGH200-04 {Rc1/2} FGH300-04 {Rc1/2} 0.05 0.05 0.05 Pressure drop (MPa) Pressure drop (MPa) Pressure drop (MPa) 0.01 0.01 0.01 0.005 0.005 0.005 0.001 10 30 50 70 100 0.001 10 30 50 70 100 0.001 10 30 50 70 100 Flow rate (L/min) Flow rate (L/min) Flow rate (L/min) FGH100-06