E-M5 thread depth 10 6 38 76 46 Motor wire (300mm) Photo micro sensor wire (300mm) 2-M2.5 thread depth 4 3 10 8 J 25 25 27 J x K Stroke + 220 10 Stroke + 127 13 15 (5) 0.5 46.5 3.5 2-M6 thread depth 13 58 52 27 19 [18] 15 Stroke + 127 (39) The dimension inside [ ] shows the location at which the home position switch operates. 58 (52) 28 36: T-slot pitch U N x P 20 5 N C 1 0.2 (5.1) 10 5.8
MK(2) REAR20 30 REAR25 30 RS Q G REAR32 30 REAR40 35 RS H A RZQ MI W S CEP1 CE1 CE2 ML2B C J G5-S CV MVGQ CC RB J D-X 20Data 10-2-19 19 Series REAR Construction: 10, 15 @1 q i y u e t r o !0 @2 !4 !5 @5 @6 !2 !7 @7 !9 @3 !8 @0 !1 w N@4 !6 !3 REAR10 Component Parts No. Description No. Material Aluminum alloy Description Note Material Note Hard anodized Wear ring A Special resin Body q !
Gasket Carbon steel Pin B NBR 19 36 Piston seal Carbon steel Spacer NBR 20 37 Rolled steel Round head Phillips screw 38 Rolled steel Pin A 39 Replacement Parts/Seal Kit Steel wire Bracket spring 40 Contents Kit no.
bolt MY1H LZ Stroke Bore size (Shock absorber stroke) T S E EA EB W h TT Stroke adjustment unit Shock absorber FC FA EY EC (mm) E EA EB EC EY h S T TT FA FC Shock absorber model Applicable cylinder W F MY1H25 18 9 40 7.5 53.5 16 21 3.5 46.7 7 53 RB1007 5 (Max.16.5) MY1H32 25 14 45.6 9.5 67.5 23 20 4.5 67.3 12 64 RB1412 8 (Max.20) MY1H40 31 19 55 11 82 24.5 26 4.5 67.3 12 9 (Max.25) 75
Required facility water system
18.5 33.1 21 10 15 40.2 AS221F-U01-10 20.9 17 8.9 23.3 14.5 1/4 4 18.5 17.2 32.5 AS221F-U02-04 31.1 32 26.6 39.4 34.4 11 23.9 15.5 6 33.1 AS221F-U02-06 31.3 15.2 27.2 18.5 8 36.4 AS221F-U02-08 33.6 18.5 33.9 21 10 19 43.2 AS221F-U02-10 35.5 19 11 26.4 15.5 3/8 6 23 19.4 37.9 AS321F-U03-06 52.5 37.6 32.6 45 40 15.2 29.5 18.5 8 41 AS321F-U03-08 54.9 18.5 31.8 21 10 43.3 AS321F-U03-10 56.8
Output On when all Inputs are On, Unused inputs considered On OR 19 Output On when at least one input On, Unused inputs considered Off XOR 13 Exclusive OR; Output On when only One of Two Inputs is On NAND 19 Not AND; Output On when all Inputs Off, Unused inputs considered Off NOR 19 Not OR; Output On when at least one Input is Off, Unused inputs considered On NOT 10 Inverts a signal; changes
Note) Breathing hole (M3 x 0.5) 3.7 3.7 13.7 1 SUPz VACz OUT port (4, 5/32") SUP, VAC port (4, 5/32") OUTx 3 EXHc ATMc 2 5 EXH, ATM port (4, 5/32") 38 2-M3 x 0.5 thread depth 3.5 Bracket mounting hole L-bracket (Option) Flat bracket (Option) 6-3.5 19 74 2-3.5 19 27 19 64 Minimium bending radius 80 28 Body +50 0 3000 15 35 (30.9) 4 8.7 9.9 Cable connector (4-wire) Straight type (Option) 7
VQZ115l-lMl VQ110l-lLl 2.10-19
JIS B 1181 Class 3 M10 x 1.25 JIS B 4636 JIS B 4636 2 point angle socket 13 17 13 2 point angle socket 17 JIS B 1181 Class 3 M12 x 1.75 JIS B 4636 JIS B 4636 2 point angle socket 17 19 17 2 point angle socket 19 Operating Cautions Counting speed of the counter Be aware that if the speed of the stroke reading cylinder with brake is faster than the counting speed of the counter, the counter
Made to Order Specifications (For details, refer to page 6-17-19.)
812 796 853 837 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 stations Station n L1 L2 1573
Size 10/15 Size 20/30/40 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Angle adjustment 5 Single flat Key B port B port 0 0 0 0 10 10 19 19 to to to to 80 80 0 A port 0 17 ve at A port 17 fl oo ve le gr ng oo Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
Please contact SMC for further information. 11-10-19
When using auto switches, do not operate in an environment with strong magnetic fields. 19 Series RQ Actuator Precautions 3 Be sure to read before handling. Maintenance Warning 1. Perform maintenance according to the procedure indicated in the instruction manual. If handled improperly, malfunction and damage of machinery or equipment may occur. 2.
1.25 18.5 Rod end thread adapter X 25 34.5 16.5 M10 x 1.25 22.5 L1 28 40.5 22.5 M14 x 1.5 28.5 For details about the rod end thread adapter and rod end nut, refer to page 10-5-16. 10-5-12 12 Compact Low Friction Cylinder Metal Seal Series MQQ Foot style: MQQTL 10, 16, 20 L Special cap bolt B + Stroke Bore size (mm) Stroke range (mm) A B L LD LG LH LY LH 10 10 to 40 44.3 31.5 8 4.5 2.8 19
Made to Order Specifications (For details, refer to page 6-17-19.)
Auto switch CUJ cylinder Cylinder B Cylinder A Auto switch Magnetic substance Non-magnetic spacer of 2.5 mm or more Without Shielding Plate d Bore (mm) 10 L 6 8 L d 19 6 19 6 19.5 6 The space can be reduced by attaching shielding plates (steel plates 0.2 to 0.3 mm thick) to the sides of the cylinders facing each other.
Single Clevis (Double clevis pivot bracket) Double Clevis (Single clevis pivot bracket) DDH10 8 10 10 14 14 DJ 7 10 10 14 16 DI 17 22 27 32 38 CDH10 8 10 10 14 14 DH 11 13 13 17 19 CJ 7 10 10 14 16 DF 4 7 10 12 14 CI 17 22 27 32 38 DE 3.5 3.5 3.5 5.5 6 CH 11 13 13 17 19 DB 23 27 31 37 48 CF 4 7 10 12 14 CE 3.5 3.5 3.5 5.5 6 DA 53 67 85 103 122 CB 23 27 31 37 48 CA 53 67 85 103 122 Part no
19 Double Power Cylinder (Without non-rotating mechanism) Series MGZR 20, 25, 32, 40, 50, 63, 80 How to Order MGZ R 100 40 Z Z73 Number of auto switches Without non-rotating mechanism Nil S 2 pcs. 1 pc.