53.5 P = 43 53.5 B B B B 9 9 B 23 20 SMC SMC SMC 9 A PA A B B A PA A B L1 L2 L2 L1 B A PA A B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B SMC A PA A B B A (A, B port) 4n-1/4, 3/8 PA A L side R side L side R side (2n-1/8) 38 D side D side 68.5 68.5 3 120.5 (
LEF D-M9NAV D-M9NA D-M9BA D-M9BAV D-M9PAV D-M9PA Auto switch model In-line Perpendicular In-line Perpendicular In-line Perpendicular Electrical entry direction LEJ 3-wire 2-wire Wiring type NPN PNP Output type LEL 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage LEM 10 mA or less Current consumption 24 VDC (10 to 28 VDC) Load voltage
A B C D 43 Non-standard Motor Series LJ1H10 High Rigidity Direct Acting Guide Motor Output Ground Ball Screw 50W 12mm/12mm lead Horizontal Mount How to Order Stroke 1 LJ1H10 F W X10 PB 1 G Cable entry direction Top entry Left entry Cable entry direction Switch Motor specification Power supply voltage F R L T B Nil W Axial Right Left Top Bottom 100/115VAC (50/60Hz) None Matsushita Electric
D-A9V 10 6 6 8.5 10 D-M9 D-F9W D-M9V D-F9WV 5.5 (4) 3 (2) 3 (3) 4 (3) 6 (4) Interference Note) Figures in parentheses are the case for D-M9, D-M9V switch types.
D. 7 to 9:P368010-26 Applicable cable O.
It is set in Pr.43 OPR method" for basic OPR parameters.) Pr.43 OPR method Operation details Deceleration is initiated by the OFF --> ON of the near-point dog. (Speed is reduced to Pr.47 Creep speed"). The operation stops once after the near-point dog turns ON and then OFF. Later the operation restarts and then stops at the first zero signal to complete the OPR.
Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V
LAT LEJS40 LEJS63 Applicable auto switches D-M9N(V)-900, D-M9P(V)-900, D-M9B(V)-900 D-M9NW(V)-900, D-M9PW(V)-900, D-M9BW(V)-900 LZ *4 Please consult with SMC for non-standard strokes as they are produced as special orders. LC3F2 * Specifications and dimensions for the 25A-series are the same as standard products.
Output Power Current Load Load Current Applicable voltage consumption voltage current leakage load drop D-M9N D-M9NV D-M9NW D-M9NWV NPN DC28V type or less At 10mA DC512 0.8V or 100A or Relay 10mA 40mA less less at PLC 24V or less or less IC circuit D-M9P D-M9PV D-M9PW D-M9PWV DC24V (4.5 to 28V) At 40mA 2V or less PNP type D-M9B D-M9BV D-M9BW D-M9BWV DC24V DC24V 2.5 to 4V 0.8mA or less (DC10
Alarm detection . 43 (1) Alarm group distinction . 43 (2) Parallel I/O signal output when an Alarm is generated . 43 (3) Alarms and countermeasures . 44 2 No.SFOD-OMT0012-A JXC3 Series/Controller Setting Software 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
4.8 (1),I/O (2), (3) (1) 4 OUT0-OUT3 ALARM OUT0 OUT1 OUT2 OUT3 B OFF OFF ON OFF OFF C OFF OFF OFF ON OFF D OFF OFF OFF OFF ON E OFF OFF OFF OFF OFF *ALARM (2) I/O SVRESETON SVRE SETON B RESET C RESET D OFF RESET E OFF OFF 43 No.SFOD-OMT0011CN-A (3) (3-1) code <> OFF OFF (0-098) C RESET <> ON SVRE ON <> <> DRIVE ON(0-099) C RESET <> (0-149) RESET SVON <> D <> <> (0-901) E
D L1 VMG KN KN 861 KN Series Nozzle for One-touch fitting/KN (mm) Model Nozzle size D Applicable fitting size d L1 A Weight (g) KN-Q06-100 KN-Q06-150 KN-Q06-200 KN-Q08-150 KN-Q08-200 KN-Q10-200 KN-Q10-250 KN-Q12-250 KN-Q12-300 5 5 5 9 9 16 16 23 23 18 18 18 20.5 20.5 22 22 24 24 35 35 35 39 39 43 43 45.5 45.5 6 6 6 8 8 10 10 12 12 1 1.5 2 1.5 2 2 2.5 2.5 3 D 10 A Connecting products with
flats H E E A B 2-P 2-P Port size A B Port size Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com M M 2-J, thread depth K 2-J, thread depth K DIN terminal: D Conduit terminal: T D S F Q Cable 6 to 12 Q 2 F 34 G1/2 D 25 T C C R R Width across flats H Width across flats
VXA I (DIN terminal: D) VN Main port Rc A Model B C D E F G H I J K L M N P Q R S T U LVC VNB2-10A VNB2-15A VNB3-20A VNB4-25A 3 8 1 2 3 4 1 63 42 28 14 72.5 80.5 74.5 79.5 82.5 124 125.5 142.5 52 26 4.5 24.3 2.3 25 34 55 LVA 80 90 50 60 35 40 17.5 20 84 100 92 108 83.5 89.5 88.5 94.5 91.5 97.5 135.5 151.5 137 153 154 170 62 72 31 36 5.5 6.5 28.3 33.3 2.3 2.3 30 35 43 49 60.5 73 LVH Port size
Auto switch Nil D None Built-in magnet Refer to page 308 for the part no. of auto switches.
Select the model with air flow capacity exceeding the calculated corrected air flow from data D of the table below.
Cooling water (l/min) 180C Inlet air temperature Correction factor Air flow (l/min (ANR)) Model 50C 70C 100C 41.5 43 45.5 37 43 49.5 37 43 45.5 37 42 43.5 40 44 46 39.5 43 44.5 41 43 45.5 A B C A B C A B C A B C A B C A B C A B C 35.5 36 36.5 33.5 36 38 33.5 36 36.5 33.5 35 36 34.5 36 37 34.5 35.5 36 34.5 35.5 36 38.5 40 42 36 40 45.5 36 40 42.5 36 40 41 38 40 42.5 38
Changing PD04 from 00212100 to 0021210D 0 D 41 - (2) Symbol allocation using the setup software: Changing pins CN1-16 to Gain changing selection (CDP). Change PD04 from 00212100 to 0021210D in the I/O tab. Select Single Axis Write. Cycle the power the parametersto be enabled.
Dimensions [mm] Model L1 L2 A B C D E F G J K LEPS10-25 138 152.5 61.8 20 22 30 29 20 29 39 88.2 LEPS10-50 163 177.5 24 43 34 50 24 50 60 113.2 LEPS10L-25 124 138.5 47.8 20 22 30 29 20 29 39 88.2 LEPS10L-50 149 163.5 24 43 34 50 24 50 60 113.2 394 LEPY/LEPS Series Specific Product Precautions 1 Be sure to read this before handling the products.