10-VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the 10-VQD1000 valves that are in contact with fluid are all copper free.
10-VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the 10-VQD1000 valves that are in contact with fluid are all copper free. Maximum 20 stations available as standard ; 4 port sizes available
10-VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the 10-VQD1000 valves that are in contact with fluid are all copper free.
10-VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the 10-VQD1000 valves that are in contact with fluid are all copper free. Maximum 20 stations available as standard ; 4 port sizes available
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.
VQD1000 series 4 port, direct operated, poppet solenoid valve offers large flow capacity in a compact, lightweight body. Vacuum applications (up to -100kPa) are possible. Components of the VQD1000 valves that are in contact with fluid are all copper free. The VQD series offers a remarkably quick and stable response time.
(Values at the initial period) VFN Base mounted JIS Symbol Solenoid Specifications Option Grommet (G), Plug connector (L), Plug connector (M), DIN terminal (D) 100, 200, 24 , 48 , 110 , 220 Electrical entry DC AC 50/60 Hz Coil rated voltage (V) 24, 6 , 12 , 48 Allowable voltage fluctuation (%) 15 to +10% of rated voltage Caution Coil insulation type Class E or equivalent (120C) (2) Temperature
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: E (N.O. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port
Body/Exhaust Type: C (For Manifold - Common Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum, V Port
Body, Exhaust Type: A (Single Unit - Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Air Operated: Q1 (Air Operated, Supply Valve; N.C; Release Valve: N.C.), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: Y (For Pressure Switch for Vacuum: 2m Lead Wire w/Connector; Pressure Sensor Assembly: 3m w/Lead Wire), Vacuum, V Port: 06 [ø6 One-touch Fitting
Body/Exhaust Type: H (For Manifold - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 07 (ø0.7), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor
How to Order ZM L Nozzle diameter 05 07 10 13 15 0.5 mm 0.7 mm 1.0 mm 1.3 mm 1.5 mm Release flow rate adjusting needle CE compliant Nil Q Nil L Without lock nut CE compliant With lock nut Compatible with release valves only. Vacuum port location Made to Order Refer to pages 1004 to 1006 for details.
For vacuum equipment precautions, refer to the Handling Precautions for SMC Products and the Operation Manual on the SMC website: http://www. smcworld.com ZU S 05 A Port size Nozzle diameter 05 0.5 mm 07 0.7 mm Nil 6 One-touch tting 01 Rc1/8 female thread Symbol EXH Vacuum pressure reached S 90 kPa L 48 kPa Mounting P V Caution Specications 1 .
/N.C.), 1st Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 1st Selection Quantity: 7
/N.C.), 1st Selection Vacuum V Port: 7 (Vacuum, V Port: Ø1/4), 1st Selection Quantity: 7
/N.C.), 1st Selection Vacuum V Port: 8 (Vacuum, V Port: Ø8), 1st Selection Quantity: 7
/N.C.), 1st Selection Vacuum V Port: 7 (Vacuum, V Port: Ø1/4), 1st Selection Quantity: 7
/N.C.), 1st Selection Vacuum V Port: 6 (Vacuum, V Port: Ø6), 1st Selection Quantity: 7