(Example) SS3YJ5-20-03 . 1 set (manifold base) SYJ512-5LZ-M5 . 2 sets (valve) SYJ500-10-1A . 1 set (blanking plate assembly) SS3YJ5-41R-03-C6 . 1 set (manifold base) SYJ514R-5G . 2 sets (valve) SYJ500-10-3A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
How to Order 03 ADM200 1 Thread type Operating time/Applicable compressor Nil N F Rc NPT G Nil 2 sec/min (1 time/min) /3.7 to 37 kW 4 sec/min (2 times/min) /37 to 75 kW 6 sec/min (3 times/min) /75 to 110 kW 8 sec/min (4 times/min) /220 to 370 kW 4 6 8 Port size Voltage OUT IN Symbol 04 03 100 VAC Hz 1 3 8 3 8 50 60 200 VAC Hz 50 60 240 VAC Hz 50 60 110 VAC Hz 50 60 220 VAC Hz 50 60 24 VDC
Thread type Nil R, Rc N NPT F G 1 4 Port size 02 Female Female Male Female Female Male 10 1 2 14 20 1 1 Male Male Male VEX 03 3 8 1 AN 04 1 2 06 3 4 AMC Specifications JIS Symbol Ambient and fluid temperature Fluid Compressed air 5 to 60C 0.1 MPa or less Element inlet pressure Noise reduction Oil mist removal 35 dB or more 99.9% or more How to Order Oil Bowl Assembly Drain cock (Standard
pressure Maximum operating pressure Regulating pressure range Rc 1/8, NPT 1/8 (Female thread) Air 1.2 MPa 0.8 MPa Standard: 0.2 to 0.7 MPa, Low pressure use (0.2 MPa setting): 0.05 to 0.2 MPa 5 to 60C (No freezing) Relieving type 0.065 Ambient and operating temperature range Construction Weight (kg) Model Port size IN Model OUT ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
Tel: 03-3502-2740 Fax: 03-5251-7240 SMC CORPORATION 1st printing OctOfber 1988. O-
Example) 10-ARP30K-03BG-1RY Clean room compliant, copperfree, fluorine-free, silicone-free Clean room compliant Symbol Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without mounting option With bracket With set nut (For
B 1 4 B 3 8 04 B 1 2 1 4 B 1 B 1 2 20 2B IN-OUT reversal direction -T Element service indicator Option HA AT ID AMG AFF AM Misc. 14-20-31 3 Series AMH Flow Characteristics/Select the model taking the max. flow capacity into Element oil saturation Initial condition Note) Compressed air over max. flow line in the table below may not meet the specifications of the product.
"MFLD, VFS, 4/5 PORT SOLENOID VALVE, N lb
Base Mounted Wiring: 01FD (Base Mounted Plug-in w/D-sub Connector on D Side), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 01SU (Base Mounted Plug-in for Serial Transmission), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 01T (Base Mounted Plug-in w/Terminal Blocks), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 10 (Base Mounted Non Plug-in Individual Lead Wire Entry), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 01T (Base Mounted Plug-in w/Terminal Blocks), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4), Thread: T (NPTF)
Base Mounted Wiring: 01CD (Base Mounted Plug-in w/Multi-connector on D Side), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)
Base Mounted Wiring: 01FU (Base Mounted Plug-in w/D-sub Connector on U Side), Stations: 8 Stations, Passage: 1 [P and EA,EB: Common, Port A,B: Side (Type 31, Port A,B: Top)], Port Size: 02 (1/4)