As a guide, when W + P0a > P0A, adjust P1, so that it could be W + P1a = P0A. (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Installing a regulator with check valve at position (b) can decrease lurching during descent, and actuation delay during ascent.

fitting dimension Y W Plate thickness ARP20(K), ARP30(K) : Max. 3.5 ARP40(K) : Max. 5 OUT IN 1021 1021 Z Pressure Gauge Option Digital pressure switch (Electrical entry: Wiring top entry) Digital pressure switch (Electrical entry: Wiring bottom entry) Option Round type pressure gauge J J J H Dimensions Center of piping H Center of piping H Center of piping Standard specifications Model P1

Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 707 Series ARP20/30/40 Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option

Valve r opens through the stem, and the outlet pressure is released to the inlet side (Figure 2). 765 ARP20/30/40 Series Dimensions 2 x P1 (Port size) A Pressure gauge (Option) Q C OUT IN K V P2 (Pressure gauge port size) B R Bleed port F S U D N Bracket (Option) J M T Panel fitting dimension Y W Plate thickness ARP20(K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option

K), ARP30(K): Max. 3.5 ARP40(K): Max. 5 OUT IN Z Pressure Gauge Option Digital pressure switch (Electrical entry: Wiring top entry) Digital pressure switch (Electrical entry: Wiring bottom entry) Square embedded type pressure gauge Option Round type pressure gauge J J J J H Dimensions Center of piping H H Center of piping H Center of piping Center of piping Standard specifications Model P1

Assembly of a piston and a seal (KSYP-13). 454 Regulator AR10-A to AR40-A Series Dimensions AR10-A to AR40-06-A 2 x P1 (Port size) J A AC-A AF-A B C AF-A OUT IN H AR-A AR-A V AL-A Q AW-A (Pressure gauge port size) Pressure gauge (Option) 2 x P2 AC-B R S AF-A F AF-A U D Bracket (Option) AR -A -B N J M T AL-A AW -A -B Panel fitting dimensions AW Y AG W E AV IN OUT AF Z Plate thickness AR10-

: Inlet pressure P1: Inlet pressure 15-16-10 11 Air Saving Valve Pressure Valve/Flow Valve Series ASR/ASQ Dimensions Pressure Valve: Series ASR Variable set pressure type Fixed set pressure type (-F20) L1 L1 L2 d L2 d M M D1 D1 D2 D2 L6 L6 L3 L4 AS H H ASP (Width across flats) (Width across flats) ASN D3 D3 AQ A1 A1 ASV L5 L5 A2 A2 AK ASS T T ASR ASF Model T H D1 D2 D3 L1 L2 L6 A2 M L5 A1

AWM AWD EX: How to obtain the mist generating pressure differential if the flow rate obtained in q above is 35m3/min and the line pressure (primary pressure P1) is 0.7MPa : Extend horizontally from the point at which the flow rate is 35m3/min to obtain the point that intersects with P1 = 0.7MPa.

attachment Description 0.1 0.07 0.1 0.2 0.3 O Center of rotation Gripper fingers G Attachment and load center of gravity Attachments Rotation time/90 s Load How to use the graph Moment of inertia I: kgm2 (a2 + b2 + 12h2) (m1 + m2) I = 12 x 106 [Example 1] Moment of Inertia: 1 x 10-5 kgm Rotation time: 0.3s/90 To select model MRHQ10 It can be used because the point of intersection P1

Inlet pressure (IN) Pressure in diaphragm chamber When the inlet pressure (P1) is higher than the regulating pressure, the check valve w closes and operates as a normal regulator (Figure 1). When the inlet pressure (P1) is shut off and released, the check valve w opens and the pressure in the diaphragm chamber q is released into the inlet side (Figure 2).

pressure (MPa) 0.4MPa Discharge flow rate (l/min) SUP = 0.5MPa 0.3 0.3MPa SUP = 0.5MPa 150 10 0.4MPa SUP = 0.5MPa 0.2MPa 0.4MPa 0.2 100 0.3MPa 0.3MPa 5 0.2MPa 0.1 50 0.2MPa 00 5 10 00 5 10 15 00 50 100 150 Flow rate (l/min) Air consumption (l/min [ANR]) Operating cycle (Hz) 4 Series PA3000 Dimensions PAm331m-m03 152 4-7 64 2-M5 with depth 8 139 10 10 120 95 Bottom view without foot SUP (P1

Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).

Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above). 20 For Air Digital Flow Switch Series PFA How to order PFW3 0 0 A Remote Type Display Unit Unit specification Flow rate range Nil M With unit switching function Fixed SI unit Note) 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 1 0

Note ) 2 position double and 3 position cannot be mounted. 40.6 3(R2) 5(R1) P1 Po 1(P) Circuit diagram Plug-in type Plug lead type SUP blocking plate VVQ5000-16A-1 EXH blocking plate VVQ5000-16A-2 18.5 20.2 When 2 or more different pressures are supplied to one manifold, blocking plates are installed between stations under different pressures. 28.8 44.6 R P R R P R R P R SUP/EXH passages

Pressure Momentary change P1 P2 Set value Anti-chattering function Devices such as large bore cylinders and high-flow vacuum ejectors consume a large volume of air when they operate, and this may cause a momentary drop in the primary pressure.

Q2 +COM 30.30.4 4 L L 5 DC24V LO L 6 DC12V M M 5 MO M 5 4300 5MMO 6 B 6() 9 - No.ZB-OM00301 / kPa / P1 0-101 15V2F.S.7 P3 -100100 15V2F.S.7 8 EA EAM SI 9 NPN2 EAP [psi] 8 0-101 8 EB EBM SI 9 PNP2 EBP [psi] 8 8 FA FAM SI 9 NPN2 FAP [psi] 8 -100100 8 FB FBM SI 9 PNP2 FBP [psi] 8 73m 8 9kPa G 2m V 10 11 12 C2 2 B C4 4 N1 1/8 N3 5/32 K 12 L2 2 L4 4


When P1 (inlet pressure) becomes lower than P2 (outlet pressure), the check valve opens and the pressure in the diaphragm chamber is discharged to the P1 side.
This allows the outlet pressure to flow back rapidly to the inlet side due to the mechanism that opens the main valve.
The AR20K-B to AR60K-B and the AR20K-D to AR40K-D series are regulators with a backflow function.


When P1 (inlet pressure) becomes lower than P2 (outlet pressure), the check valve opens and the pressure in the diaphragm chamber is discharged to the P1 side.
This allows the outlet pressure to flow back rapidly to the inlet side due to the mechanism that opens the main valve.
The AR20K-B to AR60K-B and the AR20K-D to AR40K-D are regulators with a backflow function.

Part Number Description: 63MM MY1B PARTS    Product Line: A   Product Line Description: ACTUATOR    Family Code: 464   Family Description: MY1B GUIDED CYLINDER    Class Code: P1    Click here to report information errorImage shown may not match exact part number, 63MM MY1B PARTS, ACTUATOR, MY1B GUIDED CYLINDER, P1